Avalanche-photodiode-based photon counter echo photon number resolving

2004 ◽  
Author(s):  
Josef Blazej ◽  
Ivan Prochazka ◽  
Karel Hamal
2019 ◽  
Vol 9 (13) ◽  
pp. 2638 ◽  
Author(s):  
Cai ◽  
Chen ◽  
Chen ◽  
Ma ◽  
Xu ◽  
...  

In this paper, we reconstructed the positive operator-valued measure (POVM) of a photon-number-resolving detector (PNRD) based on a multi-pixel photon counter (MPPC) by means of quantum detector tomography (QDT) at 791 nm and 523 nm, respectively. MPPC is a kind of spatial-multiplexing PNRD with a silicon avalanche photodiode (Si-APD) array as the photon receiver. Experimentally, the quantum characteristics of MPPC were calibrated at 2 MHz at two different wavelengths. The POVM elements were given by QDT. The fidelity of the reconstructed POVM elements is higher than 99.96%, which testifies that the QDT is reliable to calibrate MPPC at different wavelengths. With QDT and associated Wigner functions, the quantum properties of MPPC can be calibrated more directly and accurately in contrast with those conventional methods of modeling detectors.


2011 ◽  
Vol 84 (5) ◽  
Author(s):  
H. M. Chrzanowski ◽  
J. Bernu ◽  
B. M. Sparkes ◽  
B. Hage ◽  
A. P. Lund ◽  
...  

2004 ◽  
Author(s):  
Edo Waks ◽  
Eleni Diamanti ◽  
Yoshihisa Yamamoto

2009 ◽  
Vol 17 (21) ◽  
pp. 18782 ◽  
Author(s):  
Guang Wu ◽  
Yi Jian ◽  
E. Wu ◽  
Heping Zeng

2009 ◽  
Vol 95 (13) ◽  
pp. 131118 ◽  
Author(s):  
Xiuliang Chen ◽  
E Wu ◽  
Lilin Xu ◽  
Yan Liang ◽  
Guang Wu ◽  
...  

2007 ◽  
Vol 46 (7) ◽  
pp. 1009 ◽  
Author(s):  
Kenji Tsujino ◽  
Makoto Akiba ◽  
Masahide Sasaki

Sensors ◽  
2020 ◽  
Vol 20 (11) ◽  
pp. 3331
Author(s):  
Yang Yu ◽  
Bo Liu ◽  
Zhen Chen ◽  
Kangjian Hua

In this paper, a true random coding photon counting LIDAR is described, in which a Gm-APD (Geiger mode avalanche photodiode) acts as the true random sequence signal generator. The true random coding method not only improves the anti-crosstalk capability of the system, but also greatly reduces the 1-bit missed detection caused by the limited Gm-APD count rate. The experiment verifies the feasibility of the true random sequence used in a photon counting LIDAR ranging system, and a simple and intuitive evaluation model of true random sequence autocorrelation is proposed. Finally, the influence of system parameters (mean echo photon number, mean pulse count density, sequence length, mean noise count) on detection probability is explored. In general, this paper proves that the true random code photon counting LIDAR is an effective target detection method, and provides a new idea for the research of an anti-crosstalk LIDAR system.


2017 ◽  
Vol 7 (1) ◽  
Author(s):  
Xiuliang Chen ◽  
Chengjie Ding ◽  
Haifeng Pan ◽  
Kun Huang ◽  
Julien Laurat ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document