Electrical characterization of an ion-beam-mixed metal/polymer system

Author(s):  
Runhui Huang ◽  
Ryan E. Giedd
Author(s):  
E. Hendarto ◽  
S.L. Toh ◽  
J. Sudijono ◽  
P.K. Tan ◽  
H. Tan ◽  
...  

Abstract The scanning electron microscope (SEM) based nanoprobing technique has established itself as an indispensable failure analysis (FA) technique as technology nodes continue to shrink according to Moore's Law. Although it has its share of disadvantages, SEM-based nanoprobing is often preferred because of its advantages over other FA techniques such as focused ion beam in fault isolation. This paper presents the effectiveness of the nanoprobing technique in isolating nanoscale defects in three different cases in sub-100 nm devices: soft-fail defect caused by asymmetrical nickel silicide (NiSi) formation, hard-fail defect caused by abnormal NiSi formation leading to contact-poly short, and isolation of resistive contact in a large electrical test structure. Results suggest that the SEM based nanoprobing technique is particularly useful in identifying causes of soft-fails and plays a very important role in investigating the cause of hard-fails and improving device yield.


2001 ◽  
Vol 353-356 ◽  
pp. 591-594
Author(s):  
C. Serre ◽  
D. Panknin ◽  
A. Pérez-Rodríguez ◽  
A. Romano-Rodríguez ◽  
J.R. Morante ◽  
...  

2003 ◽  
Vol 16 (2) ◽  
pp. 199-206 ◽  
Author(s):  
S. Smith ◽  
A.J. Walton ◽  
S. Bond ◽  
A.W.S. Ross ◽  
J. Tom ◽  
...  

2017 ◽  
Author(s):  
V. Harimohan ◽  
Mukul Gupta ◽  
Shilpam Sharma ◽  
B. Sundaravel ◽  
P. Magudapathy ◽  
...  

Author(s):  
Werner Lehner ◽  
Siegfried Pauthner ◽  
Herbert Radeck ◽  
Udo Weber ◽  
Jérôme Touzel

Abstract Dynamic Random Access Memory (DRAM) is the one most widespread commodity product of the microelectronic industry. Although the basis structure is quite simple, an indepth electrical characterization of the single cell is mostly correlated with huge efforts in terms of test patterns due to the multiple possibilities for leakage of the cell itself [1]. A direct characterization of the access transistor is not possible because of the missing contact on the drain side (Deep Trench side). A tentative method to overcome this problem has been reported by G. Zimmermann, by using a front side Focused Ion Beam (FIB) contact to access the drain [2]. Unfortunately this method is limited to “coarse” technologies down to 0.15µm due to the resolution of the FIB probe. In addition, the backside contacting via trench allows the measurement of resistance and/or leakage elements at the interface buried strap, Poly 1-Poly 2 within DT (process conditioned). This paper presents an innovative way to contact the access transistor from the backside of the die, using the deep trench of the cell itself as connection to the drain of the investigated device. The backside contact to the polysilicon filled DT is the key aspect of the method and is realised by backside Focused Ion Beam.


Nanopages ◽  
2006 ◽  
Vol 1 (2) ◽  
pp. 255-262 ◽  
Author(s):  
E. Horváth ◽  
P. L. Neumann ◽  
A. L. Tóth ◽  
É. Vázsonyi ◽  
A. A. Koós ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document