Dynamic range enhancement in high-speed image sensors

2000 ◽  
Author(s):  
S. E. Alexandrov ◽  
Gennadii A. Gavrilov ◽  
V. K. Gusev ◽  
E. E. Mukhin ◽  
Galina Y. Sotnikova
Sensors ◽  
2015 ◽  
Vol 15 (11) ◽  
pp. 28224-28243 ◽  
Author(s):  
Zhiyuan Gao ◽  
Congjie Yang ◽  
Jiangtao Xu ◽  
Kaiming Nie

1992 ◽  
Vol 258 ◽  
Author(s):  
M J Powell ◽  
I D French ◽  
J R Hughes ◽  
N C Bird ◽  
O S Davies ◽  
...  

ABSTRACTWe have developed a technology for 2D matrix-addressed image sensors using amorphous silicon photodiodes and thin film transistors. We have built a small prototype, having 192×192 pixels with a 20μm pixel pitch, and assessed its performance. The nip photodiodes can have dark current densities of less than 1011 A.cm-2 (up to 5V reverse bias) and peak quantum efficiencies of 88% (at 580nm). We operated the sensor in real time mode at high speed (50 Hz frame rate and 64μS line time). The image sensor has a low noise performance giving a dynamic range in excess of 104. The maximum crosstalk is about 2%, which allows at least 50 grey levels. The bottom contact of the photodiode acts as a light shield from light through the substrate, which enables the sensor to be operated as an intimate contact image sensor to image a document placed directly on top of the array. In this mode, the CTF was 75% at 2 lp.mm1. Good quality images are demonstrated in both front projection and intimate contact imaging modes.


2010 ◽  
Vol 1 (SRMS-7) ◽  
Author(s):  
David Pennicard ◽  
Heinz Graafsma ◽  
Michael Lohmann

The new synchrotron light source PETRA-III produced its first beam last year. The extremely high brilliance of PETRA-III and the large energy range of many of its beamlines make it useful for a wide range of experiments, particularly in materials science. The detectors at PETRA-III will need to meet several requirements, such as operation across a wide dynamic range, high-speed readout and good quantum efficiency even at high photon energies. PETRA-III beamlines with lower photon energies will typically be equipped with photon-counting silicon detectors for two-dimensional detection and silicon drift detectors for spectroscopy and higher-energy beamlines will use scintillators coupled to cameras or photomultiplier tubes. Longer-term developments include ‘high-Z’ semiconductors for detecting high-energy X-rays, photon-counting readout chips with smaller pixels and higher frame rates and pixellated avalanche photodiodes for time-resolved experiments.


2010 ◽  
Vol 42 (2) ◽  
pp. 300-309 ◽  
Author(s):  
Jordan T. Shin ◽  
Eugene V. Pomerantsev ◽  
John D. Mably ◽  
Calum A. MacRae

Phenotype-driven screens in larval zebrafish have transformed our understanding of the molecular basis of cardiovascular development. Screens to define the genetic determinants of physiological phenotypes have been slow to materialize as a result of the limited number of validated in vivo assays with relevant dynamic range. To enable rigorous assessment of cardiovascular physiology in living zebrafish embryos, we developed a suite of software tools for the analysis of high-speed video microscopic images and validated these, using established cardiomyopathy models in zebrafish as well as modulation of the nitric oxide (NO) pathway. Quantitative analysis in wild-type fish exposed to NO or in a zebrafish model of dilated cardiomyopathy demonstrated that these tools detect significant differences in ventricular chamber size, ventricular performance, and aortic flow velocity in zebrafish embryos across a large dynamic range. These methods also were able to establish the effects of the classic pharmacological agents isoproterenol, ouabain, and verapamil on cardiovascular physiology in zebrafish embryos. Sequence conservation between zebrafish and mammals of key amino acids in the pharmacological targets of these agents correlated with the functional orthology of the physiological response. These data provide evidence that the quantitative evaluation of subtle physiological differences in zebrafish can be accomplished at a resolution and with a dynamic range comparable to those achieved in mammals and provides a mechanism for genetic and small-molecule dissection of functional pathways in this model organism.


Sensors ◽  
2018 ◽  
Vol 18 (4) ◽  
pp. 1166 ◽  
Author(s):  
Neale Dutton ◽  
Tarek Al Abbas ◽  
Istvan Gyongy ◽  
Francescopaolo Mattioli Della Rocca ◽  
Robert Henderson

Sign in / Sign up

Export Citation Format

Share Document