Factors affecting microcalcification detection of wide-angle digital breast tomosynthesis and strategies for improving performance

Author(s):  
Xiaoyu Duan ◽  
Hailiang Huang ◽  
Chloe Leigh Ong ◽  
Wei Zhao
2019 ◽  
Vol 54 (2) ◽  
pp. 83-88 ◽  
Author(s):  
Paola Clauser ◽  
Pascal A.T. Baltzer ◽  
Panagiotis Kapetas ◽  
Ramona Woitek ◽  
Michael Weber ◽  
...  

2016 ◽  
Author(s):  
Andria Hadjipanteli ◽  
Premkumar Elangovan ◽  
Padraig T. Looney ◽  
Alistair Mackenzie ◽  
Kevin Wells ◽  
...  

Breast Care ◽  
2017 ◽  
Vol 12 (2) ◽  
pp. 91-96 ◽  
Author(s):  
Sylvia Heywang-Köbrunner ◽  
Alexander Jaensch ◽  
Astrid Hacker ◽  
Sabina Wulz-Horber ◽  
Thomas Mertelmeier ◽  
...  

Background: The purpose of this study was to countercheck the equivalence of single-view digital breast tomosynthesis (DBT) or DBT with additional views (DBT+AV) compared to traditional standard assessment by additional views (AV) in patients with a screen-detected abnormality. Patients and Methods: Patients with a screen-detected abnormality were consecutively invited to obtain 1 single-view wide-angle DBT in addition to the indicated AV. The study was approved by the local ethics committee and by the Federal Office for Radiation Protection. Results: This study is based on 311 lesions in 285 patients with a follow-up of > 2 years and/or biopsy. Counting BI-RADS 0 and 3 as positive calls, the sensitivity/specificity of DBT+AV versus DBT only versus AV only were 96.4/54.3%, 96.4/56.6%, and 90.9/42.2%, respectively. The specificities and BI-RADS classifications differed significantly (p < 0.01). AV appeared unnecessary in 88.8% of the cases. Conclusion: DBT appeared to be at least equivalent to AV for assessing indeterminate screen-detected lesions and could replace AV for most lesions. To obtain the extra information appears possible without increasing the overall radiation dose. Subsequent blinded reader studies are ongoing.


Author(s):  
Paola Clauser ◽  
Pascal A. T. Baltzer ◽  
Panagiotis Kapetas ◽  
Ramona Woitek ◽  
Michael Weber ◽  
...  

Abstract Objectives To evaluate the diagnostic performance in the assessment setting of three protocols: one-view wide-angle digital breast tomosynthesis (WA-DBT) with synthetic mammography (SM), two-view WA-DBT/SM, and two-view digital mammography (DM). Methods Included in this retrospective study were patients who underwent bilateral two-view DM and WA-DBT. SM were reconstructed from the WA-DBT data. The standard of reference was histology and/or 2 years follow-up. Included were 205 women with 179 lesions (89 malignant, 90 benign). Four blinded readers randomly evaluated images to assess density, lesion type, and level of suspicion according to BI-RADS. Three protocols were evaluated: two-view DM, one-view (mediolateral oblique) WA-DBT/SM, and two-view WA-DBT/SM. Detection rate, sensitivity, specificity, and accuracy were calculated and compared using multivariate analysis. Reading time was assessed. Results The detection rate was higher with two-view WA-DBT/SM (p = 0.063). Sensitivity was higher for two-view WA-DBT/SM compared to two-view DM (p = 0.001) and one-view WA-DBT/SM (p = 0.058). No significant differences in specificity were found. Accuracy was higher with both one-view WA-DBT/SM and two-view WA-DBT/SM compared to DM (p = 0.003 and > 0.001, respectively). Accuracy did not differ between one- and two-view WA-DBT/SM. Two-view WA-DBT/SM performed better for masses and asymmetries. Reading times were significantly longer when WA-DBT was evaluated. Conclusions One-view and two-view WA-DBT/SM can achieve a higher diagnostic performance compared to two-view DM. The detection rate and sensitivity were highest with two-view WA-DBT/SM. Two-view WA-DBT/SM appears to be the most appropriate tool for the assessment of breast lesions. Key Points • Detection rate with two-view wide-angle digital breast tomosynthesis (WA-DBT) is significantly higher than with two-view digital mammography in the assessment setting. • Diagnostic accuracy of one-view and two-view WA-DBT with synthetic mammography (SM) in the assessment setting is higher than that of two-view digital mammography. • Compared to one-view WA-DBT with SM, two-view WA-DBT with SM seems to be the most appropriate tool for the assessment of breast lesions.


Sign in / Sign up

Export Citation Format

Share Document