A comparison of fat reduction efficacy using combined non-invasive and minimally invasive laser lipolysis system

Author(s):  
Seokwon Oh ◽  
Ji-Young Lee ◽  
Han-Young Ryu ◽  
Young-Seok Seo
BMC Biology ◽  
2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Alexander Ziegler ◽  
Christina Sagorny

Abstract Background In zoology, species descriptions conventionally rely on invasive morphological techniques, frequently leading to damage of the specimens and thus only a partial understanding of their structural complexity. More recently, non-destructive imaging techniques have successfully been used to describe smaller fauna, but this approach has so far not been applied to identify or describe larger animal species. Here, we present a combination of entirely non-invasive as well as minimally invasive methods that permit taxonomic descriptions of large zoological specimens in a more comprehensive manner. Results Using the single available representative of an allegedly novel species of deep-sea cephalopod (Mollusca: Cephalopoda), digital photography, standardized external measurements, high-field magnetic resonance imaging, micro-computed tomography, and DNA barcoding were combined to gather all morphological and molecular characters relevant for a full species description. The results show that this specimen belongs to the cirrate octopod (Octopoda: Cirrata) genus Grimpoteuthis Robson, 1932. Based on the number of suckers, position of web nodules, cirrus length, presence of a radula, and various shell characters, the specimen is designated as the holotype of a new species of dumbo octopus, G. imperator sp. nov. The digital nature of the acquired data permits a seamless online deposition of raw as well as derived morphological and molecular datasets in publicly accessible repositories. Conclusions Using high-resolution, non-invasive imaging systems intended for the analysis of larger biological objects, all external as well as internal morphological character states relevant for the identification of a new megafaunal species were obtained. Potentially harmful effects on this unique deep-sea cephalopod specimen were avoided by scanning the fixed animal without admixture of a contrast agent. Additional support for the taxonomic placement of the new dumbo octopus species was obtained through DNA barcoding, further underlining the importance of combining morphological and molecular datasets for a holistic description of zoological specimens.


2018 ◽  
Vol 100-B (12) ◽  
pp. 1640-1646 ◽  
Author(s):  
M. R. Medellin ◽  
T. Fujiwara ◽  
R. Clark ◽  
L. M. Jeys

AimsThe aim of this study was to describe, analyze, and compare the survival, functional outcome, and complications of minimally invasive (MI) and non-invasive (NI) lengthening total femoral prostheses.Patients and MethodsA total of 24 lengthening total femoral prostheses, 11 MI and 13 NI, were implanted between 1991 and 2016. The characteristics, complications, and functional results were recorded. There were ten female patients and ten male patients. Their mean age at the time of surgery was 11 years (2 to 41). The mean follow-up was 13.2 years (seven months to 29.25 years). A survival analysis was performed, and the failures were classified according to the Modified Henderson System.ResultsThe overall implant survival was 79% at five, ten, and 20 years for MI prostheses, and 84% at five years and 70% at ten years for NI prostheses. At the final follow-up, 13 prostheses did not require further surgery. The overall complication rate was 46%. The mean revision-free implant survival for MI and NI prostheses was 59 months and 49 months, respectively. There were no statistically significant differences in the overall implant survival, revision-free survival, or the distribution of complications between the two types of prosthesis. Infection rates were also comparable in the groups (9% vs 7%; p = 0.902). The rate of leg-length discrepancy was 54% in MI prostheses and 23% in NI prostheses. In those with a MI prosthesis, there was a smaller mean range of movement of the knee (0° to 62° vs 0° to 83°; p = 0.047), the flexion contracture took a longer mean time to resolve after lengthening (3.3 months vs 1.07 months; p < 0.001) and there was a lower mean Musculoskeletal Tumor Society (MSTS) score (24.7 vs 27; p = 0.295).ConclusionThe survival and complications of MI and NI lengthening total femoral prostheses are comparable. However, patients with NI prosthesis have more accurate correction of leg-length discrepancy, a better range of movement of the knee and an improved overall function.


Biomedicines ◽  
2021 ◽  
Vol 9 (11) ◽  
pp. 1662
Author(s):  
Ioana Maria Maier ◽  
Adrian Cornel Maier

Many studies have tried to understand the mechanism of endometriosis and its manner of manifestation. However, the only method of diagnosis considered as the gold standard in endometriosis is an invasive method called exploratory laparoscopy. Hence, there is a need to identify non-invasive or minimally invasive methods to minimize patients’ suffering, thus increasing their addressability at the earliest possible staging of the disease, and to diagnose this condition as soon as possible. miRNAs (microRNAs) and lncRNAs (long-noncoding RNAs) are potential non-invasive diagnostic methods for endometriosis. Multiple clinical trials indicate that miRNA can be used as a non-invasive method in the diagnosis and differentiation of endometriosis stages.


2020 ◽  
Vol 12 (1) ◽  
pp. 7-19
Author(s):  
Guerrero Gutiérrez Manuel Alberto ◽  
Pérez Nieto Orlando Rubén ◽  
Eder Iván Zamarrón López ◽  
Jesús Salvador Sánchez Díaz ◽  
Escarramán Martínez Diego ◽  
...  

The hemodynamic monitoring is a fundamental part of the patient in the perioperative period, during the last decade the monitoring at the patient's bedside has grown at giant steps, from the emergency area, operating room, to the Intensive Care area. One of its most important advances is the decrease in the use of pulmonary artery catheter, which is being replaced by ultrasound and less invasive monitoring techniques, in this article we will review from the beginning of the monitoring to the most used less invasive monitors currently.


2018 ◽  
Vol 44 (7) ◽  
pp. 971-975 ◽  
Author(s):  
Sreya Talasila ◽  
Rachel Evers-Meltzer ◽  
Shuai Xu

2013 ◽  
Vol 39 (2) ◽  
pp. 142-152 ◽  
Author(s):  
Aashish D. Bhatt ◽  
John C. Schuler ◽  
Maxwell Boakye ◽  
Shiao Y. Woo

Sign in / Sign up

Export Citation Format

Share Document