Active control of rotating stall using pulsed-air injection: a parametric study on a low-speed axial flow compressor

Author(s):  
Raffaello D'Andrea ◽  
Robert L. Behnken ◽  
Richard M. Murray
1997 ◽  
Vol 119 (4) ◽  
pp. 742-752 ◽  
Author(s):  
R. D’Andrea ◽  
R. L. Behnken ◽  
R. M. Murray

This paper presents the use of pulsed air injection to control rotating stall in a low-speed, axial flow compressor. In the first part of the paper, the injection of air is modeled as an unsteady shift of the compressor characteristic, and incorporated into a low dimensional model of the compressor. By observing the change in the bifurcation behavior of this model subject to nonlinear feedback, the viability of various air injection orientations is established. An orientation consistent with this analysis is then used for feedback control. By measuring the unsteady pressures near the rotor face, a control algorithm determines the magnitude and phase of the first mode of rotating stall and controls the injection of air in the front of the rotor face. Experimental results show that this technique eliminates the hysteresis loop normally associated with rotating stall. A parametric study is used to determine the optimal control parameters for suppression of stall. The resulting control strategy is also shown to suppress surge when a plenum is present. Using a high-fidelity model, the main features of the experimental results are duplicated via simulations.


1985 ◽  
Vol 22 (3) ◽  
pp. 175-181 ◽  
Author(s):  
F. A. E. Breugelmans ◽  
K. Mathioudakis ◽  
F. Casalini

2021 ◽  
Author(s):  
AbdelRahman Ahmed Kamal ◽  
Alyaa Abdelnaby Thabet ◽  
Mohamed M. A. Elnabawy

2000 ◽  
Author(s):  
Craig A. Buhr ◽  
Matthew A. Franchek ◽  
Sanford Fleeter

Abstract Presented in this paper is an analytical study evaluating the closed loop stability of rotating stall control in an axial flow compressor subject to a nonlinear spatial actuation constraint that limits the amplitude of a spatial mode input. Absolute stability of the rotating stall control system is investigated by applying the circle criterion to a linearized model of an axial compressor in series with the saturation element. This stability analysis is then used to design the gain and phase of the ‘classical’ complex gain feedback control law. Resulting is a systematic method for designing the parameters of the complex gain control law which increases the region of absolute stability guaranteed by the circle criterion for the closed-loop system.


2012 ◽  
Vol 224 ◽  
pp. 352-357
Author(s):  
Islem Benhegouga ◽  
Ce Yang

In this work, steady air injection upstream of the blade leading edge was used in a transonic axial flow compressor, NASA rotor 37. The injectors were placed at 27 % upstream of the axial chord length at blade tip, the injection mass flow rate is 3% of the chock mass flow rate, and 3 yaw angles were used, respectively -20°, -30°, and -40°. Negative yaw angles were measured relative to the compressor face in opposite direction of rotational speeds. To reveal the mechanism, steady numerical simulations were performed using FINE/TURBO software package. The results show that the stall mass flow can be decreased about 2.5 %, and an increase in the total pressure ratio up to 0.5%.


2009 ◽  
Vol 2009 (0) ◽  
pp. 377-378 ◽  
Author(s):  
Hiroaki KIKUTA ◽  
Masato FURUKAWA ◽  
Satoshi GUNJISHIMA ◽  
Kenichiro IWAKIRI ◽  
Takuro KAMEDA