Rotating Stall Control of an Axial Flow Compressor Using Pulsed Air Injection

1997 ◽  
Vol 119 (4) ◽  
pp. 742-752 ◽  
Author(s):  
R. D’Andrea ◽  
R. L. Behnken ◽  
R. M. Murray

This paper presents the use of pulsed air injection to control rotating stall in a low-speed, axial flow compressor. In the first part of the paper, the injection of air is modeled as an unsteady shift of the compressor characteristic, and incorporated into a low dimensional model of the compressor. By observing the change in the bifurcation behavior of this model subject to nonlinear feedback, the viability of various air injection orientations is established. An orientation consistent with this analysis is then used for feedback control. By measuring the unsteady pressures near the rotor face, a control algorithm determines the magnitude and phase of the first mode of rotating stall and controls the injection of air in the front of the rotor face. Experimental results show that this technique eliminates the hysteresis loop normally associated with rotating stall. A parametric study is used to determine the optimal control parameters for suppression of stall. The resulting control strategy is also shown to suppress surge when a plenum is present. Using a high-fidelity model, the main features of the experimental results are duplicated via simulations.

2000 ◽  
Author(s):  
Craig A. Buhr ◽  
Matthew A. Franchek ◽  
Sanford Fleeter

Abstract Presented in this paper is an analytical study evaluating the closed loop stability of rotating stall control in an axial flow compressor subject to a nonlinear spatial actuation constraint that limits the amplitude of a spatial mode input. Absolute stability of the rotating stall control system is investigated by applying the circle criterion to a linearized model of an axial compressor in series with the saturation element. This stability analysis is then used to design the gain and phase of the ‘classical’ complex gain feedback control law. Resulting is a systematic method for designing the parameters of the complex gain control law which increases the region of absolute stability guaranteed by the circle criterion for the closed-loop system.


Author(s):  
Anand P. Darji ◽  
Dilipkumar Bhanudasji Alone ◽  
Chetan S. Mistry

A transonic axial flow compressor undergoes severe vibrations due to instabilities like stall and surge when it operates at lower mass flow rate in the absence of any control devices. In present study, the attempt was made to understand the combine impact of circumferential casing grooves (CCG) of constant aspect ratio and different axial spacing between rotor and stator on the operating stability of single stage transonic axial compressor and that of rotor alone using numerical simulation. The optimum rotor-stator gap in the presence of grooved casing treatment was identified. The steady state numerical analysis was performed by using three-dimensional Reynolds Average Navier-Stokes equation adapting shear stress transport (SST) k-ω turbulence model. The study is reported in two sections. First section includes the detailed numerical study on baseline case having smooth casing wall (SCW). The computational results were validated with the experimental results available at Propulsion Division of CSIR-NAL, Bangalore. The computational study shows good agreement with experimental results. The second section comprises the effects of optimum designs of CCG and various axial spacing on the stall margin improvement of transonic compressor. Current computational study shows that the axial spacing between rotor and stator is an important parameter for improvement in stall margin not only for SCW but also for CCG. Therefore, the highest stall margin improvement of 9% has achieved for 75% axial spacing.


2012 ◽  
Vol 224 ◽  
pp. 352-357
Author(s):  
Islem Benhegouga ◽  
Ce Yang

In this work, steady air injection upstream of the blade leading edge was used in a transonic axial flow compressor, NASA rotor 37. The injectors were placed at 27 % upstream of the axial chord length at blade tip, the injection mass flow rate is 3% of the chock mass flow rate, and 3 yaw angles were used, respectively -20°, -30°, and -40°. Negative yaw angles were measured relative to the compressor face in opposite direction of rotational speeds. To reveal the mechanism, steady numerical simulations were performed using FINE/TURBO software package. The results show that the stall mass flow can be decreased about 2.5 %, and an increase in the total pressure ratio up to 0.5%.


2009 ◽  
Vol 2009 (0) ◽  
pp. 377-378 ◽  
Author(s):  
Hiroaki KIKUTA ◽  
Masato FURUKAWA ◽  
Satoshi GUNJISHIMA ◽  
Kenichiro IWAKIRI ◽  
Takuro KAMEDA

2006 ◽  
Vol 2006.2 (0) ◽  
pp. 149-150
Author(s):  
Sho BONKOHARA ◽  
Ken-ichiro IWAKIRI ◽  
Ryusuke OHTAGURO ◽  
Yasuhiro SHIBAMOTO ◽  
Masato FURUKAWA

Author(s):  
Qiushi Li ◽  
Tianyu Pan ◽  
Tailu Sun ◽  
Zhiping Li ◽  
Yifang Gong

Experimental investigations are conducted to study the instability evolution in a transonic axial flow compressor at four specific rotor speeds covering both subsonic and transonic operating conditions. Two routes of evolution to final instability are observed in the test compressor: at low rotor speeds, a disturbance in the rotor tip region occurs and then leads to rotating stall, while at high rotor speeds, a low-frequency disturbance in the hub region leads the compressor into instability. Different from stall and surge, this new type of compressor instability at high rotor speed is initiated through the development of a low-frequency axisymmetric disturbance at the hub, and we name it “partial surge”. The frequency of this low-frequency disturbance is approximately the Helmholtz frequency of the system and remains constant during instability inception. Finally, a possible mechanism for the occurrence of different instability evolutions and the formation of partial surge are also discussed.


Author(s):  
Daisuke Morita ◽  
Yutaka Fujita ◽  
Yutaka Ohta ◽  
Eisuke Outa

Transient characteristics as well as unsteady cascade flow fields of a three-stage axial flow compressor with compression plane wave injection from the compressor downstream were experimentally investigated by detail measurements of casing wall pressure fluctuations and unsteady velocity. The main feature of tested compressor is a shock tube facility connected in series to the compressor outlet duct in order to supply a compression plane wave which simulates the sudden rise of the compressor back pressure in a gas turbine system. Research attention is mainly focused on the unsteady behavior of surge and rotating stall coexistence phenomenon, and influence of the compression plane wave injection on the compressor operating conditions. When the compressor is connected to the capacity tank, surge and rotating stall occur simultaneously according to the capacitance increment of the whole compression system. The surge cycle changes irregularly with a throttling of the valve installed just behind the compressor and several different types of surge behaviors are observed. Furthermore, even though the compressor is operating under the stable condition, it goes into surge by injecting the compression plane wave.