X‐ray photoelectron spectroscopic study of the interaction of low energy carbon ions with GaAs and InP

1992 ◽  
Vol 10 (4) ◽  
pp. 1358-1364 ◽  
Author(s):  
P. F. A. Meharg ◽  
E. A. Ogryzlo ◽  
I. Bello ◽  
W. M. Lau
1998 ◽  
Vol 47 (4) ◽  
pp. 474-478 ◽  
Author(s):  
Laurent Köhler ◽  
Diego Gourdin ◽  
Robert Sporken ◽  
Kornely Grigorov ◽  
Joseph Riga ◽  
...  

1985 ◽  
Vol 50 (10) ◽  
pp. 2139-2145
Author(s):  
Alexander Muck ◽  
Eva Šantavá ◽  
Bohumil Hájek

The infrared spectra and powder X-ray diffraction patterns of polycrystalline YPO4-YCrO4 samples are studied from the point of view of their crystal symmetry. Mixed crystals of the D4h19 symmetry are formed over the region of 0-30 mol.% YPO4 in YCrO4. The Td → D2d → D2 or C2v(GS eff) correlation is appropriate for both PO43- and CrO43- anions.


Biochemistry ◽  
2002 ◽  
Vol 41 (15) ◽  
pp. 4809-4818 ◽  
Author(s):  
Gloria C. Ferreira ◽  
Ricardo Franco ◽  
Arianna Mangravita ◽  
Graham N. George

RSC Advances ◽  
2020 ◽  
Vol 10 (65) ◽  
pp. 39875-39880
Author(s):  
Yao Xiao ◽  
Kentaro Yamamoto ◽  
Yukiko Matsui ◽  
Toshiki Watanabe ◽  
Koji Nakanishi ◽  
...  

The reaction mechanism of the sulfur cathode in the microporous carbon during discharge was observed by operando XAS.


2021 ◽  
Vol 11 (10) ◽  
pp. 4349
Author(s):  
Tianzhong Xiong ◽  
Wenhua Ye ◽  
Xiang Xu

As an important part of pretreatment before recycling, sorting has a great impact on the quality, efficiency, cost and difficulty of recycling. In this paper, dual-energy X-ray transmission (DE-XRT) combined with variable gas-ejection is used to improve the quality and efficiency of in-line automatic sorting of waste non-ferrous metals. A method was proposed to judge the sorting ability, identify the types, and calculate the mass and center-of-gravity coordinates according to the shading of low-energy, the line scan direction coordinate and transparency natural logarithm ratio of low energy to high energy (R_value). The material identification was satisfied by the nearest neighbor algorithm of effective points in the material range to the R_value calibration surface. The flow-process of identification was also presented. Based on the thickness of the calibration surface, the material mass and center-of-gravity coordinates were calculated. The feasibility of controlling material falling points by variable gas-ejection was analyzed. The experimental verification of self-made materials showed that identification accuracy by count basis was 85%, mass and center-of-gravity coordinates calculation errors were both below 5%. The method proposed features high accuracy, high efficiency, and low operation cost and is of great application value even to other solid waste sorting, such as plastics, glass and ceramics.


Sign in / Sign up

Export Citation Format

Share Document