A Study on Superheat Utilization of Extraction Steam in a 1000MW Double Reheat Ultra-Supercritical Unit

Author(s):  
Weiliang Wang ◽  
Hai Zhang ◽  
Junfu Lv ◽  
Weidou Ni ◽  
Yongsheng Li ◽  
...  

The world’s first 1000MW double reheat ultrasupercritical unit has been in operation since September 25th, 2015 in Taizhou, China. The thermal efficiency at turbine heat-rate acceptance (THA) condition is around 51%, which is the highest among all condensing units in coal-fired power plants around the world. However, the resultant superheat degree of the extraction steam is relatively high, leading to a large temperature difference in heat transfer process in the regenerative system, thereby a great exergy loss. In order to utilize the superheat of turbine bleeds more effectively, we present a scheme by employing an outer steam cooler (OSC) after the last high pressure heater in series to use the superheat to heat the feed water. Based on the newly installed unit in Taizhou, we examine the energy saving effect of the superheat utilization of different bleeds and their possible combinations respectively. The influencing factors of the mass flow rate, superheat, and effective superheat of the extraction steam are studied. Thermodynamic analyses revealed that the second extraction steam has not only high effective superheat, but also large mass flow rate, so in the overall efficiency improvement it ranks first and the third extraction steam ranks second. Although the fourth extraction steam has the largest superheat, it ranks third as the result of relatively lower mass flow rate. It was found that at nominal load, by adopting OSC’s to utilize the superheat of the second to sixth extraction steam, temperature of the feed water can increase by 8.1 °C, 3.5 °C, 2.6 °C, 1.1 °C, and 1 °C respectively, and the net coal consumption reduces by 0.73g/kWh, 0.47g/kWh, 0.40g/kWh, 0.21g/kWh and 0.22g/kWh accordingly. Consequently, three possible schemes are recommended for future design: one is to adopt one OSC to utilize the superheat of the second extraction steam, in return of 8.1°C increment in feed water temperature and 0.73g/kWh reduction of the net coal consumption; the second is to adopt two OSC’s to utilize the superheat of the second and third extraction steam at the same time, in return of 11.4 °C increment in feed water temperature and 1.21g/kWh reduction of the net coal consumption; and the last is to apply three OSC’s to utilize the superheat of the second to the fourth extraction steam simultaneously, to achieve 13.9°C increment in feed water temperature, and 1.62g/kWh reduction of the net coal consumption.

Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2950
Author(s):  
Vinod Kumar ◽  
Liqiang Duan

Coal consumption and CO2 emissions are the major concerns of the 21st century. Solar aided (coal-fired) power generation (SAPG) is paid more and more attention globally, due to the lesser coal rate and initial cost than the original coal-fired power plant and CSP technology respectively. In this paper, the off-design dynamic performance simulation model of a solar aided coal-fired power plant is established. A 330 MW subcritical coal-fired power plant is taken as a case study. On a typical day, three various collector area solar fields are integrated into the coal-fired power plant. By introducing the solar heat, the variations of system performances are analyzed at design load, 75% load, and 50% load. Analyzed parameters with the change of DNI include the thermal oil mass flow rate, the mass flow rate of feed water heated by the solar energy, steam extraction mass flow rate, coal consumption, and the plant thermal efficiency. The research results show that, as DNI increases over a day, the coal saving rate will also increase, the maximum coal saving rate reaches up to 5%, and plant thermal efficiency reaches 40%. It is analyzed that the SAPG system gives the best performance at a lower load and a large aperture area.


2020 ◽  
Vol 197 ◽  
pp. 10003
Author(s):  
Simone Ghettini ◽  
Alessandro Sorce ◽  
Roberto Sacile

This paper presents a data–driven model for the estimation of the performance of an aircooled steam condenser (ACC) with the aim to develop an efficient online monitoring, summarized by the condenser pressure (or vacuum) as Key Performance Indicator. The estimation of the ACC performance model was based on different dataset from three different combined cycle power plants with a gross power of above 380 MWe each, focusing on stationary condition of the steam turbine. The datasets include both boundary (e.g. Ambient Temperature, Wind Speed) and operative parameters (e.g. steam mass flow rate, Steam turbine power, electrical load of the ACC fans) acquired from the power plants and some derived variable as the incondensable fraction, which calculation is here proposed as additional parameter. After a preliminary sensitivity analysis on data correlation, the paper focuses on the evaluation of different ACC Condenser models: Semi-Empirical model is described trough curves typically based on steam mass flow rate (or condenser load) and the ambient temperature as main parameters. Since monitoring based on ACC design curves Semi-Empirical models, provides biased poor results, with an error of about 15%, the curves parameters were estimated basing on training data set. Other two data driven models were presented, basing on a neural network modelling and multi linear regression technique and compared on the base of the reduced number of input at first and then including aldo the other process variables in the prediction of the condenser back pressure. Estimate the parameters of the Semi-Empirical model, results in a better prediction if just steam mass flow rate and ambient temperature are available, with an error of the 7%, thanks to the knowledge contained within the “curves shapes”, with respect to linear regression (8.3%) and Neural Network models (7.6%). Higher accuracy can be then obtained by considering a larger number of operative parameters and exploiting more complex data-driven model. With a higher number of features, the neural network model has proved a higher accuracy than the linear regression model. In fact, the mean percentage error of the NN model (2.6%), in all plant operating conditions, is slightly lower than the error of the linear regression model, but presents and much lower than the mean error of the Semi-Empirical model thanks to the additional data-based knowledge.


Author(s):  
Yujia Zhou ◽  
Hanliang Bo ◽  
Jingyu Du

With the purpose of enhancement of heat transfer performance and reduction of the volume of steam generator (SG), a structure of longitudinal finned tubes was proposed to replace the smooth tubes of SG in this paper. Taking the SG smooth tubes of Daya bay Nuclear Power plant as a reference, the simplified heat transfer model of new longitudinal finned tubes was established by ANSYS CFX. Three-dimensional numerical model was developed to investigate the fluid-solid coupled thermal hydraulic characteristics of different types of the longitudinal finned tubes compared with the smooth tubes. Analysis of calculation results were sufficiently discussed for the effect of mass flow rate, fin array, solid thermal conductivity and frictional resistance. The numerical results revealed that the heat transfer coefficient increase with the increasing mass flow rate in the secondary side. The material of the tubes has significantly influence on the heat transfer process. Different flow conditions have different thermal hydraulic characteristics. The evaluated criterion to judge the enhancement of the heat transfer of the coupled process was also proposed. The numerical results can provide some useful guidance for design optimization of longitudinal finned tubes in SG.


Author(s):  
Diab W. Abueidda ◽  
Mohamed Gadalla

Worldwide concern about the scarcity of global water resources is increasing day by day. In Gulf countries, most power plants are co-generation power desalting plants (CPDP) that generate electric energy and also produce fresh water through the desalination of seawater. Nowadays, renewable energy provides a viable solution to the scarcity of energy resources and an environmental friendly option of global economy. In this paper, thermodynamic analyses have been performed on an integrated solar-based multi-stage flash desalination/Rankine cycle system. The respective losses as well as the first-law and second-law efficiencies for the system have been evaluated. The first-law and second-law efficiencies of the solar field were found to be 61.70% and 31.74%, respectively. The solar thermal field is based on direct steam generation method. Moreover, the mass flow rate through the Rankine cycle has been optimized to produce the maximum power. The optimal mass flow rate through the Rankine cycle found to be 51 kg/s. Furthermore, this paper presents and investigates a model of distillation plant that can use the heat rejected from the condenser of the Rankine cycle. The model is analyzed and validated with other results gained from literature. It found that the highest exergy destruction through the distillation unit occurs within the stages of the MSF unit. The percentage of exergy destruction in the MSF stages was found to be 75.41% of the total exergy destruction in the distillation unit. Additionally, this study verifies that increasing number of MSF stages decreases the percentage of exergy destruction.


Author(s):  
B. Facchini ◽  
M. Surace ◽  
S. Zecchi

Significant improvements in gas turbine cooling technology are becoming harder as progress goes over and over. Several impingement cooling solutions have been extensively studied in past literature. An accurate and extensive numerical 1D simulation on a new concept of sequential impingement was performed, showing good results. Instead of having a single impingement plate, we used several perforated plates, connecting the inlet of each one with the outlet of the previous one. Main advantages are: absence of the negative interaction between transverse flow and last rows impinging jets (reduced deflection); better distribution of pressure losses and heat transfer coefficients among the different plates, especially when pressure drops are significant and available coolant mass flow rate is low (lean premixed combustion chamber and LP turbine stages). Practical applications can have a positive influence on both cooled nozzles and combustion chambers, in terms of increased cooling efficiency and coolant mass flow rate reduction. Calculated effects are used to analyze main influences of such a cooling system on global performances of power plants.


2013 ◽  
Vol 341-342 ◽  
pp. 1342-1345
Author(s):  
Xing Sen Yang ◽  
Jing Yin

Uniform velocity of primary air is very important in the operation of utility boilers. Regulation of the resistance of each pipe was done without pulverized coal to achieve equal flow velocity. The mass flow rate of pulverized coal and the length difference of pipes would lead to velocity variation of primary air. By the research of primary air flow and the regulation process, model of the velocity variation was built to calculate the velocity of each pipe and their difference. The arrangement of pipes and the operation parameters were taken into consideration. With the experimental data, calculation of velocity under different states was made. The velocity difference of different pipes was estimated. The length difference between pipes and the variation of the mass flow rate of pulverized coal play the most important role that affects the velocity of primary air.


2020 ◽  
Vol 191 ◽  
pp. 04005
Author(s):  
Usama Abrar ◽  
Liu Shi ◽  
Nasif Raza Jaffri ◽  
Yi Kang ◽  
Muhammad Nawaz ◽  
...  

The complex multiphase gas-solid flow has always been a point of attraction for researchers over the past decade to explore the sensing techniques to sense and measure the mass flow. Weather dilute or dense phase flow, the gas-solid flow measurement generally requires velocity profile and volumetric concentration measurement to find the mass flow rate. The nature of the solids, the environmental factors-specially moisture adversely affects the sensor readings-specifically when it is non-invasive capacitive sensors. Gas-solid flow finds its applications in power plants, food, chemical, automobile, and pharmaceutical industries. This paper aims to explore the evolution of a novel approach of using load cell in conjunction with capacitive electrodes for calculating the mass flow rate of the solids.


MECHANICAL ◽  
2015 ◽  
Vol 6 (1) ◽  
Author(s):  
Indri Yaningsih ◽  
Tri Istanto

This research examined the effect of the use of spray humidifier and pad humidifier on the productivity of a desalination unit based heat pump with using humidification and dehumidification process. In spray humidifier there were 5 pieces of sprinklers for spraying sea water. In pad humidifier, sea water was distributed evenly over the top by means of sea water flowing through perforated pipes that have been placed on pad humidifier. Tested the effect of sea water volumetric flow rate, air velocity and sea water temperature which was fed to spray humidifier and pad humidifier on the fresh water production resulted from desalination unit.The research result showed that the production of fresh water increased with the increase in the sea water volumetric flow rate, air velocity, and sea water temperature, this applies to the use of spray humidifier or pad humidifier in the desalination unit.On testing of the effect of the sea water volumetric flow rate, air velocity, and sea water temperature, the performance of spray humidifier and pad humidifier was equal in the production of fresh water, when the ratio of sea water mass flow rate to air mass flow rate of 1.34, 1.3 and 1.3, respectively.Keywords : dehumidification,desalination, humidification, pad humidifier, spray humidifier


Author(s):  
Arnold Gad-Briggs ◽  
Pericles Pilidis

The Design Point (DP) performance of a Nuclear Power Plant (NPP) is fairly straightforward to establish for a given mass flow rate, turbomachinery compressor Pressure Ratio (PR) and reactor Core Outlet Temperature (COT). The plant components are optimum for that point but this is no longer the case if the plant’s operating conditions are changed for part-load performance. Data from tests or previous operating experiences are useful in determining typical part load performance of components based on characteristic maps. However, when individual components are linked in a plant, the range of operating points for part load performances are severely reduced. The main objective of this study is to derive Off-Design Points (ODPs) for the Simple Cycle Recuperated (SCR) and Intercooled Cycle Recuperated (ICR) when considering a temperature range of −35 to 50°C and COTs between 750 to 1000°C, using a modelling & performance simulation tool designed specifically for this study, which calculates the best operational equilibrium ODPs that are critical to the economics of the NPP. Results show that the recuperator High-Pressure (HP) side and reactor pressure losses alter the actual operating parameters (mass flow rate and compressor PR). The SCR yielded a drop in plant cycle efficiency of 1% for a 4% pressure loss in comparison to the ICR (5%) for the same amount of recuperator HP losses. Other parameters such as the precooler and recuperator Low-Pressure (LP) losses still retain the same operating inlet PRs and mass flow rates regardless of the magnitude of the losses. In the absence of characteristic maps in the public domain, the ODPs have been used to produce characteristic trend maps for first order ODP calculations. The analyses intend to aid the development of cycles for Generation IV NPPs specifically Gas Cooled Fast Reactors (GFRs) and Very High Temperature Reactors (VHTRs), where helium is the coolant.