Inverse Design of Cooling of Electronic Chips Subject to Specified Hot Spot Temperature and Coolant Inlet Temperature

Author(s):  
Sohail R. Reddy ◽  
George S. Dulikravich

Most methods for designing electronics cooling schemes do not offer the information on what levels of heat fluxes are maximally possible to achieve with the given material, boundary and operating conditions. Here, we offer an answer to this inverse problem posed by the question below. Given a micro pin-fin array cooling with these constraints: - given maximum allowable temperature of the material, - given inlet cooling fluid temperature, - given total pressure loss (pumping power affordable), and - given overall thickness of the entire electronic component, find out the maximum possible average heat flux on the hot surface and find the maximum possible heat flux at the hot spot under the condition that the entire amount of the inputted heat is completely removed by the cooling fluid. This problem was solved using multi-objective constrained optimization and metamodeling for an array of micro pin-fins with circular, airfoil and symmetric convex cross sections that is removing all the heat inputted via uniform background heat flux and by a hot spot. The goal of this effort was to identify a cooling pin-fin shape and scheme that is able to push the maximum allowable heat flux as high as possible without the maximum temperature exceeding the specified limit for the given material. Conjugate heat transfer analysis was performed on each of the randomly created candidate configurations. Response surfaces based on Radial Basis Functions were coupled with a genetic algorithm to arrive at a Pareto frontier of best trade-off solutions. The Pareto optimized configuration indicates the maximum physically possible heat fluxes for specified material and constraints.

Author(s):  
Sohail R. Reddy ◽  
George S. Dulikravich

The thermal management capability of various candidates of micro-pin fin arrays is investigated. An integrated circuit having a footprint of 4 × 3 mm with micro-pin fin array having circular, airfoil and convex cross-section is considered. The three pin fin cross-sections along with the cooling schemes are optimized to handle a uniform heat flux of 500 W/cm2 applied to the top surface of the electronic chip. A fully three-dimensional, steady-state conjugate heat transfer analysis was performed on each cooling configuration and a constrained multi-objective optimization was carried out for each of the three micro-pin fin shapes to find pin fin designs configurations capable of cooling such high heat fluxes. The design variables were the geometric parameters defining each pin fin cross section, height of the chip and inlet speed of the coolant. The two simultaneous objectives were to minimize maximum temperature and pressure drop (pumping power), while keeping the maximum temperature below 85°C. A response surface was constructed for each objective function and was coupled with a genetic algorithm to arrive at a Pareto frontier of the best trade-off solutions. Stress-deformation analysis incorporating the hydrodynamic and thermal loads was performed on each of the three optimized configurations. The maximum displacement was found to be on the nano-level, and the Von-Mises stress for each configuration was found to be significantly below the yield strength of Silicon.


Author(s):  
Sohail R. Reddy ◽  
Abas Abdoli ◽  
George S. Dulikravich ◽  
Cesar C. Pacheco ◽  
Genesis Vasquez ◽  
...  

The ability of various arrays of micro pin-fins to reduce maximum temperature of an integrated circuit with a 4 × 3 mm footprint and a 0.5 × 0.5 mm hot spot was investigated numerically. Micro pin-fins having circular, symmetric airfoil and symmetric convex lens cross sections were optimized to handle a background uniform heat flux of 500 W cm−2 and a hot spot uniform heat flux of 2000 W cm−2. A fully three-dimensional conjugate heat transfer analysis was performed and a multi-objective, constrained optimization was carried out to find a design for each pin-fin shape capable of cooling such high heat fluxes. The two simultaneous objectives were to minimize maximum temperature and minimize pumping power, while keeping the maximum temperature below 85 °C. The design variables were the inlet average velocity and shape, size and height of the pin-fins. A response surface was generated for each of the objectives and coupled with a genetic algorithm to arrive at a Pareto frontier of the best trade-off solutions. Stress–deformation analysis incorporating hydrodynamic and thermal loads was performed on the three Pareto optimized configurations. Von-Mises stress for each configuration was found to be significantly below the yield strength of silicon.


2015 ◽  
Vol 137 (3) ◽  
Author(s):  
Abas Abdoli ◽  
George S. Dulikravich ◽  
Genesis Vasquez ◽  
Siavash Rastkar

Two-layer single phase flow microchannels were studied for cooling of electronic chips with a hot spot. A chip with 2.45 × 2.45 mm footprint and a hot spot of 0.5 × 0.5 mm in its center was studied in this research. Two different cases were simulated in which heat fluxes of 1500 W cm−2 and 2000 W cm−2 were applied at the hot spot. Heat flux of 1000 W cm−2 was applied on the rest of the chip. Each microchannel layer had 20 channels with an aspect ratio of 4:1. Direction of the second microchannel layer was rotated 90 deg with respect to the first layer. Fully three-dimensional (3D) conjugate heat transfer analysis was performed to study the heat removal capacity of the proposed two-layer microchannel cooling design for high heat flux chips. In the next step, a linear stress analysis was performed to investigate the effects of thermal stresses applied to the microchannel cooling design due to variations of temperature field. Results showed that two-layer microchannel configuration was capable of removing heat from high heat flux chips with a hot spot.


1968 ◽  
Vol 90 (1) ◽  
pp. 51-54 ◽  
Author(s):  
W. A. Beckman

The one-dimensional steady-state temperature distribution within an isotropic porous bed subjected to a collimated and/or diffuse radiation heat flux and a transparent flowing fluid has been determined by numerical methods. The porous bed was assumed to be nonscattering and to have a constant absorption coefficient. Part of the radiation absorbed by the porous bed is reradiated and the remainder is transferred to the fluid by convection. Due to the assumed finite volumetric heat transfer coefficient, the bed and fluid have different temperatures. A bed with an optical depth of six and with a normal incident collimated radiation heat flux was investigated in detail. The radiation incident on the bed at the fluid exit was assumed to originate from a black surface at the fluid exit temperature. The investigation covered the range of incident diffuse and collimated radiation heat fluxes expected in a nonconcentrating solar energy collector. The results are presented in terms of a bed collection efficiency from which the fluid temperature rise can be calculated.


2018 ◽  
Vol 140 (2) ◽  
Author(s):  
Chirag R. Kharangate ◽  
Ki Wook Jung ◽  
Sangwoo Jung ◽  
Daeyoung Kong ◽  
Joseph Schaadt ◽  
...  

Three-dimensional (3D) stacked integrated circuit (IC) chips offer significant performance improvement, but offer important challenges for thermal management including, for the case of microfluidic cooling, constraints on channel dimensions, and pressure drop. Here, we investigate heat transfer and pressure drop characteristics of a microfluidic cooling device with staggered pin-fin array arrangement with dimensions as follows: diameter D = 46.5 μm; spacing, S ∼ 100 μm; and height, H ∼ 110 μm. Deionized single-phase water with mass flow rates of m˙ = 15.1–64.1 g/min was used as the working fluid, corresponding to values of Re (based on pin fin diameter) from 23 to 135, where heat fluxes up to 141 W/cm2 are removed. The measurements yield local Nusselt numbers that vary little along the heated channel length and values for both the Nu and the friction factor do not agree well with most data for pin fin geometries in the literature. Two new correlations for the average Nusselt number (∼Re1.04) and Fanning friction factor (∼Re−0.52) are proposed that capture the heat transfer and pressure drop behavior for the geometric and operating conditions tested in this study with mean absolute error (MAE) of 4.9% and 1.7%, respectively. The work shows that a more comprehensive investigation is required on thermofluidic characterization of pin fin arrays with channel heights Hf < 150 μm and fin spacing S = 50–500 μm, respectively, with the Reynolds number, Re < 300.


2020 ◽  
Vol 142 (3) ◽  
Author(s):  
Ki Wook Jung ◽  
Eunho Cho ◽  
Hyoungsoon Lee ◽  
Chirag Kharangate ◽  
Feng Zhou ◽  
...  

Abstract High performance and economically viable cooling solutions must be developed to reduce weight and volume, allowing for a wide-spread utilization of hybrid electric vehicles. The traditional embedded microchannel cooling heat sinks suffer from high pressure drop due to small channel dimensions and long flow paths in two-dimensional (2D) plane. Utilizing direct “embedded cooling” strategy in combination with top access three-dimensional (3D) manifold strategy reduces the pressure drop by nearly an order of magnitude. In addition, it provides more temperature uniformity across large area chips and it is less prone to flow instability in two-phase boiling heat transfer. This study presents the experimental results for single-phase thermofluidic performance of an embedded silicon microchannel cold plate (CP) bonded to a 3D manifold for heat fluxes up to 300 W/cm2 using single-phase R-245fa. The heat exchanger consists of a 5 × 5 mm2 heated area with 25 parallel 75 × 150 μm2 microchannels, where the fluid is distributed by a 3D-manifold with four microconduits of 700 × 250 μm2. Heat is applied to the silicon heat sink using electrical Joule-heating in a metal serpentine bridge and the heated surface temperature is monitored in real-time by infrared (IR) camera and electrical resistance thermometry. The maximum and average temperatures of the chip, pressure drop, thermal resistance, and average heat transfer coefficient (HTC) are reported for flow rates of 0.1, 0.2. 0.3, and 0.37 L/min and heat fluxes from 25 to 300 W/cm2. The proposed embedded microchannels-3D manifold cooler, or EMMC, device is capable of removing 300 W/cm2 at maximum temperature 80 °C with pressure drop of less than 30 kPa, where the flow rate, inlet temperature, and pressures are 0.37 L/min, 25 °C and 350 kPa, respectively. The experimental uncertainties of the test results are estimated, and the uncertainties are the highest for heat fluxes &lt; 50 W/cm2 due to difficulty in precisely measuring the fluid temperature at the inlet and outlet of the microcooler.


Author(s):  
Rampada Rana ◽  
Alosri Prajwal ◽  
Gullapalli Sivaramakrishna ◽  
Raju Dharappa Navindgi ◽  
Nagalingam Muthuveerappan

Abstract Over the years, the requirements of higher specific thrust and lower specific fuel consumption have been necessitating a continual increase in the maximum temperature and pressure in gas turbine engines. However, such an increase has a direct impact on the structural integrity of various modules of the engine; combustor being one of the severely affected modules. This makes the combustor designer’s task of achieving the targeted life of liner, the hottest component of combustor, a challenging one. Estimation of liner metal temperature, thereby arriving at the combustor life, is an essential part of the design process. In the present study, CHT analysis of a radial annular combustor has been carried out. RANS based analysis of a sector combustor with periodicity in flow and geometry has been performed at realistic engine operating conditions using ANSYS Fluent. Predicted liner metal temperatures have been compared with the measured data and a close agreement has been noted between them, the maximum variation being ± 10%.


Author(s):  
Lakshya Bhatnagar ◽  
Guillermo Paniagua

Abstract This work aims to provide a technique with which high frequency heat flux measurement data can be acquired in systems with high operational temperatures and high-speed flows with quantifiable and accurate uncertainty estimates. This manuscript presents the detailed calibration and application of an atomic layer thermopile, for heat fluxes with a frequency bandwidth of 0 to 1MHz. Two calibration procedures with a detailed uncertainty analysis. The first procedure consists using a laser to deliver radiation heat flux, while the second consists of a convective heat blowdown experiment. The use of this probe is demonstrated in a high-speed environment at Mach 2. The sensor effectively captures the passage of the normal shock wave and the values are compared with those computed using surface temperature measurement. Finally, a numerical study is carried out to design a cooling system that will allow the sensor to survive in high temperature conditions of 1273K while the sensor film is maintained at 323K. A two-dimensional axisymmetric conjugate heat transfer analysis is carried out to obtain the desired geometry.


Author(s):  
Fre´de´ric Damian

Along with the GFR another gas-cooled reactor identified in the Gen IV technology roadmap, the VHTR is studied in France. Some models have been developed at CEA relying on existing computational tools essentially dedicated to the prismatic block type reactor. These models simulate normal operating conditions and accidental reactor transients by using neutronic [1], thermal-hydraulic, system analysis codes [2], and their coupling [3, 4]. In the framework of the European RAPHAEL project, this paper presents the results of the preliminary investigations carried out on the VHTR design. These studies aimed at understanding the physical aspects of the annular core and to identify the limits of a standard block type VHTR with regard to a degradation of its passive safety features. Analysis was performed considering various geometrical scales: fuel cell and fuel column located at the core hot spot, 2D and 3D core configurations including the coupling between neutronic and thermal-hydraulic. From the thermal analysis performed at the core hot spot, the capability to reduce the maximum fuel temperature by modifying the design parameters such as the fuel compact and the fuel block geometry was assessed. The best performances are obtained for an annular fuel compact geometry with coolant flowing inside and outside the fuel compact (ΔT > 50°C). The reliability of such design option should however be addressed with respect to its performance during the LOFC transient (the residual decay heat will be evacuated by radiation during the transient instead of conduction through graphite). As far as the fuel element geometry is concerned, a gain of approximately 50°C can be achieved by making limited changes on the fuel compact distribution in the prismatic block: reduction of the number of fuel compact in the outer ring of the fuel element where the average ratio between coolant channels and fuel compact is smaller. On the other hand, the adopted modifications should also be evaluated with respect to the maximum temperature gradient achieved in the fuel (amoeba effect). In the end, calculations performed on the full core configuration taking into account the thermal feedback showed that the radial positioning of the fuel elements allows to reduce significantly the power peaking factor and the maximum fuel temperature. The gain on the fuel temperature, which varies during the core irradiation, is in the range 100 – 150°C. Several modifications such as the increase of the bypass fraction and the replacement of a part of the graphite reflector by material with better thermal properties were also addressed in this paper.


Author(s):  
P. E. Phelan ◽  
Y. Gupta ◽  
H. Tyagi ◽  
R. Prasher ◽  
J. Cattano ◽  
...  

Increasingly, military and civilian applications of electronics require extremely high heat fluxes, on the order of 1000 W/cm2. Thermal management solutions for these severe operating conditions are subject to a number of constraints, including energy consumption, controllability, and the volume or size of the package. Calculations indicate that the only possible approach to meeting this heat flux condition, while maintaining the chip temperature below 50 °C, is to utilize refrigeration. Here we report an initial optimization of the refrigeration system design. Because the outlet quality of the fluid leaving the evaporator must be held to approximately less than 20%, in order to avoid reaching critical heat flux, the refrigeration system design is dramatically different from typical configurations for household applications. In short, a simple vapor-compression cycle will require excessive energy consumption, largely because of the superheat required to return the refrigerant to its vapor state before the compressor inlet. A better design is determined to be a “two-loop” cycle, in which the vapor-compression loop is coupled thermally to a primary loop that directly cools the high-heat-flux chip.


Sign in / Sign up

Export Citation Format

Share Document