scholarly journals Modeling and Simulation of Shock and Drop Loading for Complex Portable Electronic Systems

Author(s):  
F. Askari Farahani ◽  
M. Al-Bassyiouni ◽  
A. Dasgupta ◽  
S. Tolchinsky ◽  
J. Crystal

The dynamic response of electronic assemblies to drop and shock conditions is investigated through tests and simulation. The portable electronic product tested in this study consists of a circuit card assembly and a battery pack supported in a two-piece plastic housing with a separate battery compartment. Dynamic loading, consisting of various shock profiles, is applied using an electrodynamic shaker. A number of drop tests are also conducted on a drop tower. Fourier Transform technique (FFT) is utilized to analyze the dynamic response of the PWB and the plastic housing in the frequency domain. The loading events are modeled in ABAQUS™ [11]. Flexural strains and accelerations are compared to assess the agreement between the model results obtained here and the experimental results [10]. The long-term goal of this study is to demonstrate a systematic computational capability to predict the dynamic response and failure modes expected due to drop loading, during the design phase of future products.

2011 ◽  
Vol 133 (4) ◽  
Author(s):  
A. F. Askari Farahani ◽  
M. Al-Bassyiouni ◽  
A. Dasgupta

The development of portable electronics poses design challenges when evolving new designs for high strain-rate life cycle loading, such as in drop events, blast events, vibration, ultrasonic process steps, etc. This paper discusses an experimental investigation of the transient response of a portable electronic product and its subassemblies to dynamic mechanical loading encountered in drop and shock conditions. The portable electronic product tested in this study consists of a circuit card assembly and a battery pack supported in a two-piece plastic housing with a separate battery compartment. Dynamic loading, consisting of various shock profiles, is applied using an electrodynamic shaker. A number of drop tests are also conducted on a drop tower. Fourier transform technique (FFT) is utilized to analyze the dynamic response of the printed wiring board and the plastic housing in the frequency domain. Tests at the subassembly level are used to study the dynamic response of the individual constituents. The nonlinear interactions due to dynamic contact between these subassemblies are then investigated through shock and drop testing at the system level. These results will be used in a subsequent study to investigate the ability of finite element models to accurately capture this transient response of complex portable electronic assemblies under shock and drop loading. The long-term goal of this combined study is to demonstrate a systematic modeling methodology to predict the drop response of future portable electronic products, so that relevant failure modes can be eliminated by design iterations early in the design cycle.


2013 ◽  
Vol 27 (07) ◽  
pp. 1330004 ◽  
Author(s):  
E. SUHIR

The published work on analytical ("mathematical") and computer-aided, primarily finite-element-analysis (FEA) based, predictive modeling of the dynamic response of electronic systems to shocks and vibrations is reviewed. While understanding the physics of and the ability to predict the response of an electronic structure to dynamic loading has been always of significant importance in military, avionic, aeronautic, automotive and maritime electronics, during the last decade this problem has become especially important also in commercial, and, particularly, in portable electronics in connection with accelerated testing of various surface mount technology (SMT) systems on the board level. The emphasis of the review is on the nonlinear shock-excited vibrations of flexible printed circuit boards (PCBs) experiencing shock loading applied to their support contours during drop tests. At the end of the review we provide, as a suitable and useful illustration, the exact solution to a highly nonlinear problem of the dynamic response of a "flexible-and-heavy" PCB to an impact load applied to its support contour during drop testing.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 4048
Author(s):  
Huu Linh Nguyen ◽  
Jeasu Han ◽  
Xuan Linh Nguyen ◽  
Sangseok Yu ◽  
Young-Mo Goo ◽  
...  

Durability is the most pressing issue preventing the efficient commercialization of polymer electrolyte membrane fuel cell (PEMFC) stationary and transportation applications. A big barrier to overcoming the durability limitations is gaining a better understanding of failure modes for user profiles. In addition, durability test protocols for determining the lifetime of PEMFCs are important factors in the development of the technology. These methods are designed to gather enough data about the cell/stack to understand its efficiency and durability without causing it to fail. They also provide some indication of the cell/stack’s age in terms of changes in performance over time. Based on a study of the literature, the fundamental factors influencing PEMFC long-term durability and the durability test protocols for both PEMFC stationary and transportation applications were discussed and outlined in depth in this review. This brief analysis should provide engineers and researchers with a fast overview as well as a useful toolbox for investigating PEMFC durability issues.


2021 ◽  
Author(s):  
Joannes Gullaksen

Abstract The scope of this paper is to provide a method implemented in an application for assessment of dynamic response of free spanning pipelines subjected to combined wave and current loading. The premises for the paper are based on application development within pipeline free span evaluation in a software development project. A brief introduction is provided to the basic hydrodynamic phenomena, principles and parameters for dynamic response of pipeline free spans. The choice of method for static and dynamic span modelling has an influence on calculated modal frequencies and associated stresses. Due to the importance of frequencies and stresses for fatigue and environmental loading calculations, the choice of analysis approach influences the partial safety factor format. The aim of the structural analysis is to provide the necessary input to the calculations of VIV and force model response, and to provide realistic estimations of static loading from functional loads. Environmental flow conditions are implemented in the application, such as steady flow due to current, oscillatory flow due to waves and combined flow due to current and waves. Combined wave and current loading include the long-term current velocity distribution, short-term and long-term description of wave-induced flow velocity amplitude and period of oscillating flow at the pipe level and return period values. Inline and cross-flow vibrations are considered in separate response models. For pipelines and risers, modes are categorized in in-line or cross-flow direction. A force model is also considered for the short-term fatigue damage due to combined current and direct wave actions. Design criteria can be specified for ultimate limit state (ULS) and fatigue limit state (FLS) due to in-line and cross-flow vortex induced vibrations (VIV) and direct wave loading.


2021 ◽  
Author(s):  
Zhiyuan Han ◽  
Guoshan Xie ◽  
Haiyi Jiang ◽  
Xiaowei Li

Abstract The safety and risk of the long term serviced pressure vessels, especially which serviced more than 20 years, has become one of the most concerned issues in refining and chemical industry and government safety supervision in China. According to the Chinese pressure vessel safety specification TSG 21-2016 “Supervision Regulation on Safety Technology for Stationary Pressure Vessel”, if necessary, safety assessment should be performed for the pressure vessel which reaches the design service life or exceeds 20 years without a definite design life. However, the safety and risk conditions of most pressure vessels have little changes after long term serviced because their failure modes are time-independent. Thus the key problem is to identify the devices with the time-dependent failure modes and assess them based on the failure modes. This study provided a case study on 16 typical refining and chemical plants including 1870 pressure vessels serviced more than 20 years. The quantitative risk and damage mechanisms were calculated based on API 581, the time-dependent and time-independent failure modes were identified, and the typical pressure vessels were assessed based on API 579. Taking the high pressure hydrogenation plant as an example, this study gave the detailed assessment results and conclusions. The results and suggestions in this study are essential for the safety supervision and extending life of long term serviced pressure vessels in China.


Author(s):  
Kensuke Shiomi

Through the 2011 Tohoku Earthquake or the 2016 Kumamoto Earthquake, much larger earthquakes are considered recently in the seismic designs of large steel-frame structures. When structures are exposed by these severe ground motions, partial destructions in the structures, such as damage or fracture of members could happen. Especially, the low cycle fatigue of steel structures because of the repeated load from these long-term ground motions is a serious problem. However, current seismic performance evaluation method based on nonlinear dynamic analysis considers only elastic and plastic deformation of each member, excluding the fracture of members. If this member fracture happens during earthquakes, there is considered to be many effects on the seismic performance, like the changes of the vibration property, the dynamic response and the energy absorbance capacity of structures. Therefore, the fracture of members is preferably taken into account in the seismic performance evaluation for these large earthquakes. This paper proposes the dynamic analysis method for steel-frame structures which can express the member fracture. Dynamic analyses considering and not considering member fracture under the repeated loads supposing the long-term earthquake are conducted to the FEM model of full-scale structure. By comparing each result, the effects of considering member fracture to the seismic performance such as the dynamic response and the energy absorbance capacity are discussed.


Author(s):  
Pradeep Lall ◽  
Prashant Gupta ◽  
Arjun Angral ◽  
Jeff Suhling

Failures in electronics subjected to shock and vibration are typically diagnosed using the built-in self test (BIST) or using continuity monitoring of daisy-chained packages. The BIST which is extensively used for diagnostics or identification of failure, is focused on reactive failure detection and provides limited insight into reliability and residual life. In this paper, a new technique has been developed for health monitoring and failure mode classification based on measured damage precursors. A feature extraction technique in the joint-time frequency domain has been developed along with pattern classifiers for fault diagnosis of electronics at product-level. The Karhunen Loe´ve transform (KLT) has been used for feature reduction and de-correlation of the feature vectors for fault mode classification in electronic assemblies. Euclidean, and Mahalanobis, and Bayesian distance classifiers based on joint-time frequency analysis, have been used for classification of the resulting feature space. Previously, the authors have developed damage pre-cursors based on time and spectral techniques for health monitoring of electronics without reliance on continuity data from daisy-chained packages. Statistical Pattern Recognition techniques based on wavelet packet energy decomposition [Lall 2006a] have been studied by authors for quantification of shock damage in electronic assemblies, and auto-regressive moving average, and time-frequency techniques have been investigated for system identification, condition monitoring, and fault detection and diagnosis in electronic systems [Lall 2008]. However, identification of specific failure modes was not possible. In this paper, various fault modes such as solder inter-connect failure, inter-connect missing, chip delamination chip cracking etc in various packaging architectures have been classified using clustering of feature vectors based on the KLT approach [Goumas 2002]. The KLT de-correlates the feature space and identifies dominant directions to describe the space, eliminating directions that encode little useful information about the features [Qian 1996, Schalkoff 1972, Theodoridis 1998, Tou 1974]. The clustered damage pre-cursors have been correlated with underlying damage. Several chip-scale packages have been studied, with leadfree second-level interconnects including SAC105, SAC305 alloys. Transient strain has been measured during the drop-event using digital image correlation and high-speed cameras operating at 100,000 fps. Continuity has been monitored simultaneously for failure identification. Fault-mode classification has been done using KLT and joint-time-frequency analysis of the experimental data. In addition, explicit finite element models have been developed and various kinds of failure modes have been simulated such as solder ball cracking, trace fracture, package falloff and solder ball failure. Models using cohesive elements present at the solder joint-copper pad interface at both the PCB and package side have also been created to study the traction-separation behavior of solder. Fault modes predicted by simulation based pre-cursors have been correlated with those from experimental data.


Author(s):  
V. L. Semenov-Tyan-Shanskiy ◽  
◽  
A.S. Bal’tserovich ◽  
A.N. Sazonova ◽  
O.A. Loginovskaya ◽  
...  

This article presents the history and structure of the school of clinical trials monitors in Russia, the reasons for its opening in 2011, as well as the results of a survey of graduates. The authors discuss in detail what tasks they faced in creating a high-quality, modern, interactive educational program that is sustainable in the long term. Shows the important role of collaboration between academic institutions and business companies directly involved in clinical research on a daily basis. The structure of the course is presented, as well as teaching materials and electronic systems and technologies are used. Separately, the experience of operating a school during the COVID-19 pandemic is given, an analysis of the course functioning in fully online format, the positive and negative aspects of this approach. The second part of the article presents the results of a survey of graduates of the course for 9 years: from their satisfaction with training, to their further professional career (a total of 8 questions). In conclusion, the authors present their personal attitude to this educational project.


1999 ◽  
Author(s):  
Brian J. Lewis ◽  
Hilary Sasso

Abstract Processing fine pitch flip chip devices continues to pose problems for packaging and manufacturing engineers. Optimizing process parameters such that defects are limited and long-term reliability of the assembly is increased can be a very tedious task. Parameters that effect the robustness of the process include the flux type and placement parameters. Ultimately, these process parameters can effect the long-term reliability of the flip chip assembly by either inhibiting or inducing process defects. Therefore, care is taken to develop a process that is robust enough to supply high yields and long term reliability, but still remains compatible with a standard surface mount technology process. This is where process optimization becomes most critical and difficult. What is the optimum height of the flux thin film used for a dip process? What force is required to insure that the solder bumps make contact with the pads? What are the limiting boundaries in which high yields and high reliabilities are achieved, while maintaining a streamlined, proven process? The following study evaluates a set of process parameters and their impact on process defects and reliability. The study evaluates process parameters including, flux type, flux application parameters, placement force and placement accuracy to determine their impact. Solder voiding, inadequate solder wetting, and crack propagation and delamination in the underfill layer are defects examined in the study. Assemblies will be subjected to liquid-to-liquid thermal shock testing (−55° C to 125°C) to determine failure modes due to the aforementioned defects. The results will show how changes in process parameters effect yield and reliability.


2012 ◽  
Vol 2012 (1) ◽  
pp. 000891-000905 ◽  
Author(s):  
Rainer Dohle ◽  
Stefan Härter ◽  
Andreas Wirth ◽  
Jörg Goßler ◽  
Marek Gorywoda ◽  
...  

As the solder bump sizes continuously decrease with scaling of the geometries, current densities within individual solder bumps will increase along with higher operation temperatures of the dies. Since electromigration of flip-chip interconnects is highly affected by these factors and therefore an increasing reliability concern, long-term characterization of new interconnect developments needs to be done regarding the electromigration performance using accelerated life tests. Furthermore, a large temperature gradient exists across the solder interconnects, leading to thermomigration. In this study, a comprehensive overlook of the long-term reliability and analysis of the achieved electromigration performance of flip-chip test specimen will be given, supplemented by an in-depth material science analysis. In addition, the challenges to a better understanding of electromigration and thermomigration in ultra fine-pitch flip-chip solder joints are discussed. For all experiments, specially designed flip-chips with a pitch of 100 μm and solder bump diameters of 30–60 μm have been used [1]. Solder spheres can be made of every lead-free alloy (in our case SAC305) and are placed on a UBM which has been realized for our test chips in an electroless nickel process [2]. For the electromigration tests within this study, multiple combinations of individual current densities and temperatures were adapted to the respective solder sphere diameters. Online measurements over a time period up to 10,000 hours with separate daisy chain connections of each test coupon provide exact lifetime data during the electromigration tests. As failure modes have been identified: UBM consumption at the chip side or depletion of the Nickel layer at the substrate side, interfacial void formation at the cathode contact interface, and - to a much lesser degree - Kirkendall-like void formation at the anode side. A comparison between calculated life time data using Weibull distribution and lognormal distribution will be given.


Sign in / Sign up

Export Citation Format

Share Document