Unusual Fast Evaporation From Nanoholes

Author(s):  
Zhi Huang ◽  
Yuanchen Hu ◽  
Kang Liu ◽  
Xuejiao Hu

Water evaporation is an important physical phenomenon that occurs in nature and several industrial applications such as food drying processes, cooling in air-conditioning systems and desalination. In all these systems, it is necessary to have a good prediction and control of evaporation rate as a function of various system parameters. Attempts to understand the affecting factors have mostly focus on the flow rates of gas or water streams, relative humidity of the air, presence of dissolved or suspended material in the water, temperatures of the air and water streams. However, as water surface partially covered (less surface area) is generally thought to have lower evaporation rate, little notice has ever put on it. Here we consider the evaporation case of water surface covered with nano-through-hole lid (NHL) of which the radius size is nearly equal to the average free path of the vapor. Using a gravimetric method, we experimentally measured the evaporation rate of water at the orifice of the nano-holes. The results indicate that the evaporation rate is 1–6 times faster than the non-sheltered water surface with the same liquid area. Moreover, with the porosity of the lid decreasing, the evaporation rate per unit area increases. A theoretical model is developed for this novel phenomenon from the view of molecular dynamics during evaporation and vapor diffusion. We envision that this finding may have new inspirations on phase change phenomenon in nano-confined space and put forward one new way for promoting evaporation of liquid.

2018 ◽  
Vol 70 ◽  
pp. 02006
Author(s):  
Agnieszka Garnysz-Rachtan ◽  
Zbigniew Zapałowicz

Thermal calculations for indoor swimming pools require that amount of water evaporated from the pool's water surface, as well as water evaporated from the floor surrounding the pool and from the bodies of the occupants are to be determined. It means in practice that amount of vapor transferred to the air in the pool hall depends most of all on physical parameters of water and air. One of more important factors that affect water evaporation is also the way the pool is operated. The present article shows only chosen relations applied to determine the values of evaporation rate from occupied pool. The relations also account for the mode of pool's operation. The aim of the paper is to analyse the effect of changes of temperature and of relative air humidity in the hall, of water temperature and of air velocity above the water surface, as well as of the number of occupants on moisture gains in the hall. The above data let choose the right relation to be applied in calculations for the water evaporation rate.


Author(s):  
Safa M Aldarabseh ◽  
Parviz Merati

Abstract This experiment was done to predict the evaporation rate from the wavy water surface under the different convection regimes ( free, forced, and mixed) at turbulent airflow conditions over a wide range of the ratio(Gr/Re2 ). Evaporation rate from wavy water surface is strongly affected by combinations between wave steepness and main airflow velocity above the wavy water surface. Experimental results show that no pattern can be followed for which combinations of evaporation rate will increase. Thus, only two facts can be noticed: the evaporation rate is larger than that measured under the same airflow velocity conditions with no waves existing on evaporated water surface because the airflow is smooth and attached along the still water surface and when increasing the wave steepness(H/L,H/T), Airflow will separate at the lee side of wave crest near to the bottom of the wave trough. Thus, vortex will generate in the airflow separation region. These vortexes are unstable and cause an increase in turbulence, reducing the water surface's resistance to vertical transport water vapor and increasing the evaporation rate. Also, experimental results show that the evaporation rates are somewhat less than that measured under the same airflow velocity with smaller wave steepness due to air trapped region observed at the leeside of the wave crest near the bottom of the wave trough. Evaporation rate is increasing with increase airflow velocity under the same convection regime.


Author(s):  
C. Jothikumar ◽  
Revathi Venkataraman ◽  
T. Sai Raj ◽  
J. Selvin Paul Peter ◽  
T.Y.J. Nagamalleswari

Wireless sensor network is a wide network that works as a cutting edge model in industrial applications. The sensor application is mostly used for high security systems that provide safety support to the environment. The sensor system senses the physical phenomenon, processes the input signal and communicates with the base station through its neighbors. Energy is the most important criterion to support a live network for long hours. In the proposed system, the EUCOR (Efficient Unequal Clustering and Optimized Routing) protocol uses the objective function to identify the efficient cluster head with variable cluster size. The computation of the objective function deals with the ant colony approach for minimum energy consumption and the varying size of the cluster in each cycle is calculated based on the competition radius. The system prolongs the lifespan of the nodes by minimizing the utilization of energy in the transmission of packets in the networks when compared with the existing system.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jihun Choi ◽  
Hansol Lee ◽  
Bokyeong Sohn ◽  
Minjae Song ◽  
Sangmin Jeon

AbstractWe developed a 3D solar steam generator with the highest evaporation rate reported so far using a carbonized luffa sponge (CLS). The luffa sponge consisted of entangled fibers with a hierarchically porous structure; macropores between fibers, micro-sized pores in the fiber-thickness direction, and microchannels in the fiber-length direction. This structure remained after carbonization and played an important role in water transport. When the CLS was placed in the water, the microchannels in the fiber-length direction transported water to the top surface of the CLS by capillary action, and the micro-sized pores in the fiber-thickness direction delivered water to the entire fiber surface. The water evaporation rate under 1-sun illumination was 3.7 kg/m2/h, which increased to 14.5 kg/m2/h under 2 m/s wind that corresponded to the highest evaporation rate ever reported under the same condition. The high evaporation performance of the CLS was attributed to its hierarchically porous structure. In addition, it was found that the air temperature dropped by 3.6 °C when the wind passed through the CLS because of the absorption of the latent heat of vaporization. The heat absorbed by the CLS during water evaporation was calculated to be 9.7 kW/m2 under 1-sun illumination and 2 m/s wind, which was 10 times higher than the solar energy irradiated on the same area (1 kW/m2).


2017 ◽  
Vol 25 (1) ◽  
pp. 19-23 ◽  
Author(s):  
Róbert Turza ◽  
Belo B. Füri

Abstract As the number of indoor swimming pools and wellness centers are currently growing, it is necessary to concentrate on the parameters of indoor environments. These parameters are necessary for the design of the HVAC systems that operate these premises. In indoor swimming-pool facilities, the energy demand is large due to ventilation losses from exhaust air. Since water evaporates from a pool’s surface, exhaust air has a high water content and specific enthalpy. In this paper the results of the water evaporation rate measured from swimming pool surfaces at higher thermal water temperatures are described.


1961 ◽  
Vol 41 (1) ◽  
pp. 199-203 ◽  
Author(s):  
A. C. Carder

In a 3-year free-water evaporation study, an evaporimeter tank in the open field lost 34.5 per cent more water than a tank sheltered by buildings and trees. Meteorological factors responsible for this difference appear to be high wind velocities and long daily periods of sunshine. Changes in temperature regime had no effect.Difference in evaporation from the two tanks led to examination of data obtained over 35 years from the sheltered tank. It was found that, although there was a progressive decrease in amount of evaporation over the years from this tank, rainfall at the same time had increased and that the effect of this increase on evaporation was roughly equal to that of all other factors affecting evaporation, such as a change in exposure, etc. Thus, the comparatively low rate of evaporation from the sheltered tank was undoubtedly due in part to the proximity of buildings and trees which had been established.


Author(s):  
N.N. Novikov ◽  

A method for calculating the parameters of the microclimate in a livestock building using water-evaporative air conditioning is described. It makes it possible to choose a rational temperature and humidity conditions for a room in hot weather, calculate the required air exchange, water evaporation rate and select the appropriate equipment.


Water SA ◽  
2020 ◽  
Vol 46 (2 April) ◽  
Author(s):  
IA Obiora-Okafo ◽  
OD Onukwuli ◽  
NC Eli-Chukwu

Dye usage for industrial applications has been on the increase and these activities generate large amounts of dye-constituted wastewater that should be treated before environmental discharge or reuse. Various studies have shown the application of natural organic polymer (NOP) coagulants in dye removal from industrial wastewater. In this research, the coagulation performances of Vigna unguiculata (VU) and Telfairia occidentalis (TO) for colour removal from crystal Ponceau 6R dye synthetic wastewater was studied. The proximate compositions, structure, and surface morphologies of the coagulants were investigated using standard methods, i.e. Fourier-Transform infrared (FTIR) spectroscopy, and scanning electron microscopy (SEM). Colour removal was evaluated through the time-dependent decrease in particle concentration and thus growth of flocs. Effects of the process parameters, including pH, coagulant dosage, dye concentration (DC), settling time, and temperature were preliminarily tested and the best range experimentally determined. The optimal operating conditions established were pH 2, 800 mg∙L−1 coagulant dosage, 100 mg∙L−1 dye concentration, 300 min, and 303 K. The order of greatest removal was VUC > TOC with optimum efficiency of 93.5% and 90.7%, respectively. The values of K and α obtained for VUC and TOC were 8.09 x 10−4 L∙mg−1∙min−1, 1.7 and 9.89 x 10-4 L∙mg−1∙min−1, 1.6, respectively. Coagulation time, Tag, calculated and deduced from the particle distribution plot, showed a rapid coagulation process. Coagulation-adsorption kinetics indicated agreement with the pseudo-second-order model deducing that chemisorption is the rate-controlling step. It further indicates that particle adsorption on the polymer surfaces occurred mostly as a mono-molecular layer and according to the chemisorption mechanism. Cross-validation showed good prediction of the experimental data. The selected coagulants have the potential for application as efficient coagulants while also showing significant adsorption characteristics. The application of kinetics and modelling in separation processes involving particle transfer is especially required in wastewater treatment.


2018 ◽  
Vol 2 (4) ◽  
pp. 68 ◽  
Author(s):  
Emil Chibowski ◽  
Aleksandra Szcześ ◽  
Lucyna Hołysz

Using neodymium ring magnets (0.5–0.65 T), the experiments on the magnetic field (MF) effects on water evaporation rate and surface tension were performed at room temperature (22–24 °C). In accordance with the literature data, the enhanced evaporation rates were observed in the experiments conducted in a period of several days or weeks. However, the evaporated amounts of water (up to 440 mg over 150 min) in particular experiments differed. The evaporated amounts depended partially on which pole of the ring magnet was directed up. The relatively strong MF (0.65 T) caused a slight decrease in surface tension (−2.11 mN/m) which lasted longer than 60 min and the memory effect vanished slowly. The surface tension data reduced by the MF action are reported in the literature, although contrary results can be also found. The observed effects can be explained based on literature data of molecular simulations and the suggestion that MF affects the hydrogen bonds of intra- and inter-clusters of water molecules, possibly even causing breakage some of them. The Lorentz force influence is also considered. These mechanisms are discussed in the paper.


Sign in / Sign up

Export Citation Format

Share Document