A New Energy Optimization Strategy for Pumping Operation in Water Distribution Systems

Author(s):  
Dhafar Al-Ani ◽  
Saeid Habibi

As time goes on, more and more operating-modes based on changing demand profiles will be compiled to enrich the range of feasible solutions for a water distribution system. This implies the conservation of energy consumed by a water pumping station and improves the ability for energy optimization. Another important goal was improving safety, reliability, and maintenance cost. In this paper, three important goals were addressed: cost-effectives, safety, and self-sustainability operations of water distribution systems. In this work, the objective functions to optimize were total electrical energy cost, maintenance costs, and reservoir water level variation while preserving the service provided to water clients. To accomplish these goals, an effective Energy Optimization Strategy (EOS) that manages trade-off among operational cost, system safety, and reliability was proposed. Moreover, the EOS aims at improving the operating conditions (i.e., pumping schedule) of an existing network system (i.e., with given capacities of tanks) and without physical changes in the infrastructure of the distribution systems. The new strategy consisted of a new Parallel Multi-objective Particle Swarm optimization with Adaptive Search-space Boundaries (P-MOPSO-ASB) and a modified EPANET. This has several advantages: obtaining a Pareto-front with solutions that are quantitatively equally good and providing the decision maker with the opportunity to qualitatively compare the solutions before their implementation into practice. The multi-objective optimization approach developed in this paper follows modern applications that combine an optimization algorithm with a network simulation model by using full hydraulic simulations and distributed demand models. The proposed EOS was successfully applied to a rural water distribution system, namely Saskatoon West. The results showed that a potential for considerable cost reductions in total energy cost was achieved (approximately % 7.5). Furthermore, the safety and the reliability of the system are preserved by using the new optimal pump schedules.

Water ◽  
2019 ◽  
Vol 11 (3) ◽  
pp. 553 ◽  
Author(s):  
Young Choi ◽  
Joong Kim

This study proposes a multi-objective optimal design approach for water distribution systems, considering mechanical system redundancy under multiple pipe failure. Mechanical redundancy is applied to the system’s hydraulic ability, based on the pressure deficit between the pressure requirements under abnormal conditions. The developed design approach shows the relationships between multiple pipe failure states and system redundancy, for different numbers of pipe-failure conditions (e.g., first, second, third, …, tenth). Furthermore, to consider extreme demand modeling, the threshold of the demand quantity is investigated simultaneously with multiple pipe failure modeling. The design performance is evaluated using the mechanical redundancy deficit under extreme demand conditions. To verify the proposed design approach, an expanded version of the well-known benchmark network is used, configured as an ideal grid-shape, and the multi-objective harmony search algorithm is used as the optimal design approach, considering construction cost and system mechanical redundancy. This optimal design technique could be used to propose a standard for pipe failure, based on factors such as the number of broken pipes, during failure condition analysis for redundancy-based designs of water distribution systems.


2013 ◽  
Vol 353-356 ◽  
pp. 2957-2960
Author(s):  
Jia Sun ◽  
Guo Ping Yu

In study of a series of damages to water distribution systems caused by urban land subsidence, risk assessment modeling is necessary for risk management especially in Mega-cities. First of all, the Catastrophe Theory was employed to analyze the Catastrophe mechanism, and a function catastrophe simulation model was established accordingly to get the vulnerability index of water distribution system. Secondly, risk entropy model was used to analyze the risk of pipe network suffering the land subsidence with the disorder and uncertainty features according to risk theory. Finally, to get the risk index the water distribution system of Guangzhou city was taken to the risk assessment model utilizing the level of land subsidence identified by the dimensional analytical method. The results showed that the risk of land subsidence under the city water distribution system security upgrade is feasible to provide a risk assessment of the strategic decision-making model.


2021 ◽  
Vol 6 (2) ◽  
pp. 107-120
Author(s):  
Kiki Rizky Fauziah ◽  
Nora Pandjaitan ◽  
Titiek Ujianti Karunia

Water distribution systems are often problematic in terms of quantity, pressure, continuity and quality. The research aimed to analyze water distribution system of PDAM Tirta Kahuripan Kabupaten Bogor in Ciomas Permai Residence. The research was conducted by collecting primary and secondary data. Analysis of clean water distribution system was carried out using the EPANET 2.0. Ciomas Permai Residence was located in zone 6 of PDAM Tirta Kahuripan servive areas. The result showed that the quality of the distributed water was in accordance with the applicable standard and continuous for 24 hours even though there were significant discharge differences during peak hours. Based on the measurement on Sunday and Monday, the minimum discharge were 14.4 l/sec and 13.8 l/sec respectively, higher than customer requirements of 7.34 l/sec, The water distribution pressure ranged from 0.7 - 1.35 bar. The result of clean water distribution simulation using EPANET 2.0 showed that the velocity of water and headloss were not accordance with the applicable standards.


Mathematics ◽  
2020 ◽  
Vol 8 (6) ◽  
pp. 887 ◽  
Author(s):  
Alexandru Predescu ◽  
Ciprian-Octavian Truică ◽  
Elena-Simona Apostol ◽  
Mariana Mocanu ◽  
Ciprian Lupu

Water distribution is fundamental to modern society, and there are many associated challenges in the context of large metropolitan areas. A multi-domain approach is required for designing modern solutions for the existing infrastructure, including control and monitoring systems, data science and Machine Learning. Considering the large scale water distribution networks in metropolitan areas, machine and deep learning algorithms can provide improved adaptability for control applications. This paper presents a monitoring and control machine learning-based architecture for a smart water distribution system. Automated test scenarios and learning methods are proposed and designed to predict the network configuration for a modern implementation of a multiple model control supervisor with increased adaptability to changing operating conditions. The high-level processing and components for smart water distribution systems are supported by the smart meters, providing real-time data, push-based and decoupled software architectures and reactive programming.


2015 ◽  
Vol 17 (6) ◽  
pp. 891-916 ◽  
Author(s):  
Helena Mala-Jetmarova ◽  
Andrew Barton ◽  
Adil Bagirov

This paper presents an extensive analysis of the sensitivity of multi-objective algorithm parameters and objective function scaling tested on a large number of parameter setting combinations for a water distribution system optimisation problem. The optimisation model comprises two operational objectives minimised concurrently, the pump energy costs and deviations of constituent concentrations as a water quality measure. This optimisation model is applied to a regional non-drinking water distribution system, and solved using the optimisation software GANetXL incorporating the NSGA-II linked with the network analysis software EPANet. The sensitivity analysis employs a set of performance metrics, which were designed to capture the overall quality of the computed Pareto fronts. The performance and sensitivity of NSGA-II parameters using those metrics is evaluated. The results demonstrate that NSGA-II is sensitive to different parameter settings, and unlike in the single-objective problems, a range of parameter setting combinations appears to be required to reach a Pareto front of optimal solutions. Additionally, inadequately scaled objective functions cause the NSGA-II bias towards the second objective. Lastly, the methodology for performance and sensitivity analysis may be used for calibration of algorithm parameters.


2004 ◽  
Vol 6 (4) ◽  
pp. 281-294 ◽  
Author(s):  
Avi Ostfeld

Reliability is an integral part of all decisions regarding water distribution system layout, design, operation and maintenance. Providing reliability for water distribution systems is complicated due to the many factors that affect reliability, the inherent nonlinear behavior of the system and its consumers, and due to the different conflicting objectives facing a water distribution system utility. Although the reliability of water distribution systems has received considerable attention over the last two decades, there is still no common, acceptable, reliability measure or reliability assessment methodology. This paper describes the classification and reliability analysis methodologies of water distribution systems and compares two previously published algorithms for reliability evaluation of water distribution systems: a tailor-made ‘lumped supply–lumped demand’ approach used most commonly in regional water distribution systems and a general stochastic (Monte Carlo) framework suitable for any generic network.


Biofilms ◽  
2005 ◽  
Vol 2 (1) ◽  
pp. 19-25 ◽  
Author(s):  
J. Y. Hu ◽  
B. Yu ◽  
Y. Y. Feng ◽  
X. L. Tan ◽  
S. L. Ong ◽  
...  

Biofilm growth within a water distribution system could lead to operational problems such as pipe corrosion, water quality deterioration and other undesirable impacts in water distribution systems. With the high ambient temperatures experienced in Singapore, the operating environment in water distribution systems is expected to be more conducive to biofilm development. We have recently conducted a survey on biofilms potentially present in a local water distribution system.The survey results indicated that residual chlorine (±standard deviation) decreased from 1.49±0.61 mg/l (water plant outlets) to 0.82±0.21 mg/l (block pipes) or 0.18±0.06 mg/l (unit pipes), respectively. Consumed chlorine, instead of residual chlorine, was found to be correlated with biofilm bacterial population. Assimilable organic carbon (AOC) level was 160±66 μg acetate C/l, and AOC:PO4-P:NO3-N was about 8:13:1. Carbon source seemed to be the limiting nutrient for bacterial growth. The concentration of iron increased from <0.04 mg/l (water plant outlets) to 0.22±0.10 mg/l (all sites). All samples showed negative results in a coliform test. The average heterotrophic plate count (HPC) for the suspended bacteria was 20 colony-forming units (c.f.u.)/ml (2 days, 35 °C) or 290 c.f.u./ml (8 days, 35 °C). The average HPC for the biofilm bacteria was 6500 c.f.u./cm2 (2 days, 35 °C) or 29000 c.f.u./cm2 (8 days, 35 °C). High HPC values in samples B2a, B2b and B3a (representing biofilm samples at site 2 from block/unit pipes and biofilm samples at site 3 from block pipes, respectively) illustrated that the relevant sample sites had a higher probaboility of biofilm growth.


2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Gheorghe Grigoras

The problem of optimal management of a water distribution system includes the determination of the operation regime for each hydrophore station. The optimal operation of a water distribution system means a maximum attention to assess the demands of the water, with minimum electrical energy consumption. The analysis of load profiles corresponding to a water distribution system can be the first step that water companies must make to assess the electrical energy consumption. This paper presents a new method to assess the electrical load in water distribution systems, taking into account the time-dependent evolution of loads from the hydrophore stations. The proposed method is tested on a real urban water distribution system, showing its effectiveness in obtaining the electrical energy consumption with a relatively low computational burden.


2020 ◽  
Vol 17 (4) ◽  
pp. 113-117
Author(s):  
Rajanbir Kaur ◽  
Rajinder Kaur

Microbes are ubiquitous in surface as well as in ground water and some of them can make their way into potable water distribution systems. Contaminated soil with human and animal fecal matter, ill-maintained water and sewage pipelines, poor sanitation and personal hygiene are the main factors responsible for the presence of microbial pathogens in the drinking water. The presence of water-borne microbes in the potable drinking water systems determines its quality. Common microbes present in contaminated water are Shigella, Escherichia coli, Vibrio cholerae, Pseudomonas sp, Salmonella sp etc. The water-borne pathogens that reside and reproduce in water distribution system causes infection of gastrointestinal tract, urinary tract, skin, and lymph nodes. When these pathogens enter into the water distribution system pipelines they form biofilms. The formation of biofilm is a key component in microbial studies. Biofilm is the sessile aggregation of bacterial cells that adhere to each other on living or non-living surfaces and forms extracellular polymeric substances (EPS). The surface physico-chemical properties of both bacteria and substratum were important for the establishment of bacterial adhesion. Bacteria forming biofilms possesses different growth patterns, responds to specific micro-environmental conditions for the formation of structurally complex mature biofilms. In water distribution systems, adhesion of microbes to the water pipelines initiate biofilm formation which in return reduces the quality of potable water and increases the corrosion of pipes.


2021 ◽  
Vol 900 (1) ◽  
pp. 012034
Author(s):  
K Pietrucha-Urbanik ◽  
B Tchórzewska-Cieślak

Abstract Water distribution systems should have a high level of reliability and availability. Water distribution system failures should be diagnosed and categorised, according to their consequences, causes, frequency, and other important factors. A failure analysis of the water distribution system is considered in this study, as well as a method for establishing a failure susceptibility index and evaluating the risk of failures within a defined area, based on categories and zonal characteristics. A risk scale, such as tolerable, controlled, and unacceptable, will be used to assess the risk of failure. The methodology is provided to help in the performance and risk assessments of water distribution systems, as well as decision-making.


Sign in / Sign up

Export Citation Format

Share Document