An Experimental Study of Local Heat Transfer Distribution Between Blockages With Holes in a Rectangular Channel

Author(s):  
S. W. Moon ◽  
S. C. Lau

Experiments have been conducted to study heat transfer between two blockages with holes and pressure drop across the blockages, for turbulent flow in a rectangular channel. Average heat transfer coefficient and local heat transfer distribution on one of the channel walls between two blockages, and overall pressure drop across the blockages were obtained, for nine different staggered arrays of holes in the blockages and Reynolds numbers of 10,000 and 30,000. For the hole configurations studied, the blockages enhanced heat transfer by 4.6 to 8.1 times, but significantly increased the pressure drop. Smaller holes in the blockages caused higher heat transfer enhancement, but larger increase of the pressure drop than larger holes. The heat transfer enhancement was lower in the higher Reynolds number cases. Because of the large pressure drop, the heat transfer per unit pumping power was lower with the blockages than without the blockages. The local heat transfer was lower nearer the upstream blockage, the highest near the downstream blockage, and also relatively high in regions of reattachment of the jets leaving the upstream holes. The local heat transfer distribution was strongly dependent on the configuration of the hole array in the blockages. A third upstream blockage lowered both the heat transfer and the pressure drop, and significantly changed the local heat transfer distribution.

2003 ◽  
Vol 125 (4) ◽  
pp. 587-594 ◽  
Author(s):  
S. W. Moon ◽  
S. C. Lau

Experiments have been conducted to study steady heat transfer between two blockages with holes and pressure drop across the blockages, for turbulent flow in a rectangular channel. Average heat transfer coefficient and local heat transfer distribution on one of the channel walls between two blockages, and overall pressure drop across the blockages were obtained, for nine different staggered arrays of holes in the blockages and Reynolds numbers of 10,000 and 30,000. For the hole configurations studied, the blockages enhanced heat transfer by 4.6 to 8.1 times, but significantly increased the pressure drop. Smaller holes in the blockages caused higher heat transfer enhancement, but larger increase of the pressure drop than larger holes. The heat transfer enhancement was lower in the higher Reynolds number cases. Because of the large pressure drop, the heat transfer per unit pumping power was lower with the blockages than without the blockages. The local heat transfer was lower nearer the upstream blockage, the highest near the downstream blockage, and also relatively high in regions of reattachment of the jets leaving the upstream holes. The local heat transfer distribution was strongly dependent on the configuration of the hole array in the blockages. A third upstream blockage lowered both the heat transfer and the pressure drop, and significantly changed the local heat transfer distribution.


Author(s):  
Jiansheng Wang ◽  
Zhiqin Yang

The heat transfer characteristic and flow structure of fluid in the rectangular channel with different height vortex generators in small scale are investigated with numerical simulation. Meantime, the properties of heat transfer and flow of fluid in the rectangular channel are compared with the channel which located small scale vortex generator. The variation law of local heat transfer and flow structure in channel is obtained. The mechanism of heat transfer enhancement of small scale vortex generators is discussed in detail. It is found that the influence of vortex generator on heat transfer is not in proportion to the size of vortex generator. What is more, turbulent flow structure near the wall, which influences the temperature distribution near the wall, induces the variety of local heat transfer. The fluid movement towards to the wall causes the heat transfer enhanced. On the contrary, the fluid movement away from the wall decreases the local heat transfer.


2004 ◽  
Vol 126 (1) ◽  
pp. 43-53 ◽  
Author(s):  
Mary V. Holloway ◽  
Heather L. McClusky ◽  
Donald E. Beasley ◽  
Michael E. Conner

Locally averaged heat transfer measurements in a rod bundle downstream of support grids with and without flow-enhancing features are investigated for Reynolds numbers of 28,000 and 42,000. Support grids with disk blockage flow-enhancing features and support grids with split-vane pair flow enhancing features are examined. Grid pressure loss coefficients and feature loss coefficients are determined based on pressure drop measurements for each support grid design. Results indicate the greatest heat transfer enhancement downstream of the support grid designs with disk blockages. In addition, the local heat transfer measurements downstream of the split-vane pair grid designs indicate a region of decreased heat transfer below that of the hydrodynamically fully developed value. This decreased region of heat transfer is more pronounced for the lower Reynolds number case. A correlation for the local Nusselt numbers downstream of the standard support grid designs is developed based on the blockage of the support grid. In addition, a correlation for the local Nusselt numbers downstream of support grids with flow-enhancing features is developed based on the blockage ratio of the grid straps and the normalized feature loss coefficients of the support grid designs. The correlations demonstrate the tradeoff between initial heat transfer enhancement downstream of the support grid and the pressure drop created by the support grid.


Author(s):  
Zheng Li ◽  
Zhaoqing Ke ◽  
Kuojiang Li ◽  
Xianchen Xu ◽  
Yangyang Chen ◽  
...  

In this article, longitudinal vortex generator (LVG) for heat transfer enhancement in rectangular channel is investigated numerically and experimentally. Two symmetrical delta shaped plates are placed vertically at the bottom of a rectangular channel and a pair of longitudinal vortices are generated and transferred downstream. These vortices were clockwise and counterclockwise, respectively. Correspondingly, the flow has the tendency to shoot to the surface opposite to the one with the LVG, then it separates into two steams and runs back to the LVG surface. Local heat transfer enhancement in the rectangular channel varies due to this fountain effect. Size effects were discussed for two types of LVG. With the same height, the wider LVG has better thermal performance within the rectangular geometry limit. One specific LVG was fabricated and tested experimentally and results show significant heat transfer enhancement. It indicated that the LVG can enhance the heat transfer significantly and the numerical results are reliable.


Author(s):  
Mary V. Holloway ◽  
Heather L. McClusky ◽  
Donald E. Beasley ◽  
Michael E. Conner

Local, average heat transfer measurements in a rod bundle downstream of support grids with and without flow-enhancing features are investigated for Reynolds numbers of 28,000 and 42,000. Support grids with disc blockage flow-enhancing features and support grids with split-vane pair flow enhancing features are examined. Grid pressure loss coefficients and feature loss coefficients are determined based on pressure drop measurements for each support grid design. Results indicate the highest heat transfer enhancement downstream of the support grid designs with disc blockages. In addition, the local heat transfer downstream of the split-vane pair grid designs indicates a region of decreased heat transfer below that of the hydrodynamically fully-developed value. This decreased region of heat transfer is more pronounced for the lower Reynolds number case. A correlation for the local Nusselt numbers downstream of the standard support grid designs is developed based on the blockage of the support grid. In addition, a correlation for the local Nusselt numbers downstream of support grids with flow-enhancing features is developed based on the blockage ratio of the grid straps and the normalized feature loss coefficients of the support grid designs. The correlations demonstrate the tradeoff between initial heat transfer enhancement downstream of the support grid and the pressure drop created by the support grid.


Author(s):  
J.-J. Hwang ◽  
C.-S. Cheng ◽  
Y.-P. Tsia

An experimental study has been performed to measure local heat transfer coefficients and static well pressure drops in leading-edge triangular ducts cooled by wall/impinged jets. Coolant provided by an array of equally spaced wall jets is aimed at the leading-edge apex and exits from the radial outlet. Detailed heat transfer coefficients are measured for the two walls forming the apex using transient liquid crystal technique. Secondary-flow structures are visualized to realize the mechanism of heat transfer enhancement by wall/impinged jets. Three right-triangular ducts of the same altitude and different apex angles of β = 30 deg (Duct A), 45 deg (Duct B) and 60 deg (Duct C) are tested for various jet Reynolds numbers (3000≦Rej≦12600) and jet spacings (s/d = 3.0 and 6.0). Results show that an increase in Rej increases the heat transfer on both walls. Local heat transfer on both walls gradually decreases downstream due to the crossflow effect. At the same Rej, the Duct C has the highest wall-averaged heat transfer because of the highest jet center velocity as well as the smallest jet inclined angle. Moreover, the distribution of static pressure drop based on the local through flow rate in the present triangular duct is similar to that that of developing straight pipe flows. Average jet Nusselt numbers on the both walls have been correlated with jet Reynolds number for three different duct shapes.


Author(s):  
Ken-Ichiro Takeishi ◽  
Robert Krewinkel ◽  
Yutaka Oda ◽  
Yuichi Ichikawa

In the near future, when designing and using Double Wall Airfoils, which will be manufactured by 3D printers, the positional relationship between the impingement cooling nozzle and the heat transfer enhancement ribs on the target plate naturally becomes more accurate. Taking these circumstances into account, an experimental study was conducted to enhance the heat transfer of the wall jet region of a round impingement jet cooling system. This was done by installing circular ribs or vortex generators (VGs) in the impingement cooling wall jet region. The local heat transfer coefficient was measured using the naphthalene sublimation method, which utilizes the analogy between heat and mass transfer. As a result, it was clarified that, within the ranges of geometries and Reynolds numbers at which the experiments were conducted, it is possible to improve the averaged Nusselt number Nu up to 21% for circular ribs and up to 51% for VGs.


Author(s):  
Ken Kuwahara ◽  
Shigeru Koyama ◽  
Kengo Kazari

In the present study, the local heat transfer and pressure drop characteristics are investigated experimentally for the flow boiling of refrigerant HFC134a in a multi-port extruded tube of 1.06mm in hydraulic diameter. The test tube is 865mm in total length made of aluminum. The pressure drop is measured at an interval of 191 mm, and the local heat transfer coefficient is measured in every subsection of 75mm in effective heating length. Experimental ranges are as follows: the mass velocity of G = 100–700 kg/m2s, the inlet temperature of Tin = 5.9–11.4 °C and inlet pressure of about 0.5 MPa. The data of pressure drop are compared with a few previous correlations for small diameter tubes, and the correlations can predict the data relatively good agreement. The data of heat transfer coefficient is compared with the correlations of Yu et al. proposed for relatively large diameter tubes. It is found that there are some differences about two phase multiplier factor of convective heat transfer between the circular channel and rectangular channel.