Absorption-Compression Heat Pump for Space Heating and Cooling Using Organic Fluids

2000 ◽  
Author(s):  
M. Nogues ◽  
M. Valles ◽  
M. Bourouis ◽  
D. Boer ◽  
A. Coronas

Abstract The combination of compression and absorption technologies can provide heat pumps with high efficiency and a wide operating range. The aim of this research project lies in the development and testing of a gas-fired double effect absorption-compression heat pump working with organic pairs for space heating and cooling. For these applications, the use of suitable organic working pairs makes possible heat pump operation at higher temperature lifts than that of conventional water-lithium bromide systems. In our research, the combination Methanol and Tetraethylenglycoldimethylether (TEGDME) has been selected as working pair. The heat pump is targeted to operate in both cooling and heating modes. Therefore, the basic structure of the heat pump is an absorption-compression double effect cycle for cooling mode, that can be switched to a single effect cycle, in order to achieve the required higher temperature lift for the heating operation. The nominal working conditions for cooling are 5°C at the evaporator and 35 to 45°C at me absorber-condenser. These conditions can be achieved with a double effect absorption-compression cycle. Different solution circuit flow configurations as serial, parallel and reverse flow have been considered. The heating operation of the heat pump aims at a temperature of the useful delivered heat between 45 and 60°C for an evaporator temperature of 0°C. In order to achieve the required temperature lift with an attractive performance (COP in the heating mode higher than unity), the unit should operate as a single effect absorption-compression heat pump. The performance analysis was based on a thermodynamic model considering the equilibrium properties of the working pair and energy and mass balances in the different components. Results in both operating modes have been evaluated in terms of the solution flow rate, the coefficient of performance COP and the primary energy ratio PER. Very interesting performances are found even for high temperature lifts. The serial flow configuration has been selected due to its good performance and technological aspects. This work forms part of the project CLIMABGAS. A prototype of this heat pump is under construction for a cooling power of 20 kW and a heating power of 24.5 kW.

Author(s):  
Giovanni Nurzia ◽  
Giuseppe Franchini ◽  
Antonio Perdichizzi

The deployment of solar driven air conditioning is a feasible target in all countries where high solar irradiation matches high cooling loads in buildings: the goal is to gradually replace compression chillers and reduce peak electricity demand during summer. Moreover, as solar thermal collectors are installed, solar cooling systems can be profitably employed during winter. In the present work a code has been implemented for the simulation and the design optimization of combined solar heating and cooling systems. The following system layout has been considered: in warm months the cooling demand is satisfied by means of an absorption chiller — driven by a solar collector field — and a reversible heat pump operating in series. A hot storage matches the variability of solar radiation, while a cold storage smoothes the non-stationarity of cooling demand. During winter, the reversible compression heat pump operates for space heating. Solar collectors are used as thermal source at the evaporator of the heat pump, increasing its coefficient of performance. The code, based on TRNSYS platform, is able to simulate the system throughout a year. Besides TRNSYS standard components a detailed model of the absorption chiller has been included, in order to accurately simulate its off-design operation. Using an optimization tool the size of each component is identified for a given space heating and cooling demand. The minimization of life cycle costs of the system has been chosen as the objective of the optimization. Results of a case study are presented and discussed for a solar heating and cooling plant in an office building. The optimization procedure has been carried out with simulations for a typical Northern Italy town (Alpine climate) and a typical Southern Italy town (Mediterranean climate).


2018 ◽  
Vol 22 (5) ◽  
pp. 2151-2162
Author(s):  
Jose Marcos ◽  
Raquel Lizarte ◽  
Fernando Varela ◽  
Maria Palacios-Lorenzo ◽  
Ana Blanco-Marigorta

A solar cooling system with an optimized air-cooled double-effect water/LiBr absorption machine is proposed as a sustainable alternative to meet cooling demands in dry hot climates. This system allows eliminating the cooling towers in those regions of the planet where water is scarce. This work analyses the environmental benefits of this air-cooled system, as well as its environmental foot-prints, compared to a solar water-cooled single effect. In this regard, a methodology has been applied to calculate the annual saving in water consumption produced in a case study: a hospital located in Almer?a, in South of Spain. Further-more, the reduction in energy consumption and CO2 emissions is also quantified since this machine can be driven by solar energy and with higher efficiency than those of single effect.


Author(s):  
Mohammad Omar Temori ◽  
František Vranay

In this work, a mini review of heat pumps is presented. The work is intended to introduce a technology that can be used to income energy from the natural environment and thus reduce electricity consumption for heating and cooling. A heat pump is a mechanical device that transfers heat from one environmental compartment to another, typically against a temperature gradient (i.e. from cool to hot). In order to do this, an energy input is required: this may be mechanical, electrical or thermal energy. In most modern heat pumps, electrical energy powers a compressor, which drives a compression - expansion cycle of refrigerant fluid between two heat exchanges: a cold evaporator and a warm condenser. The efficiency or coefficient of performance (COP), of a heat pump is defined as the thermal output divided by the primary energy (electricity) input. The COP decreases as the temperature difference between the cool heat source and the warm heat sink increases. An efficient ground source heat pump (GSHP) may achieve a COP of around 4. Heat pumps are ideal for exploiting low-temperature environmental heat sources: the air, surface waters or the ground. They can deliver significant environmental (CO2) and cost savings.


2011 ◽  
Vol 374-377 ◽  
pp. 398-404 ◽  
Author(s):  
Ying Ning Hu ◽  
Ban Jun Peng ◽  
Shan Shan Hu ◽  
Jun Lin

A hot-water and air-conditioning (HWAC) combined ground sourse heat pump(GSHP) system with horizontal ground heat exchanger self-designed and actualized was presented in this paper. The heat transfer performance for the heat exchanger of two different pipe arrangements, three layers and four layers, respectively, was compared. It showed that the heat exchange quantity per pipe length for the pipe arrangement of three layers and four layers are 18.0 W/m and 15.0 W/m. The coefficient of performance (COP) of unit and system could remain 4.8 and 4.2 as GSHP system for heating water, and the COP of heating and cooling combination are up to 8.5 and 7.5, respectively. The power consumption of hot-water in a whole year is 9.0 kwh/t. The economy and feasibility analysis on vertical and horizontal ground heat exchanger were made, which showed that the investment cost per heat exchange quantity of horizontal ground heat exchanger is 51.4% lower than that of the vertical ground heat exchanger, but the occupied area of the former is 7 times larger than the latter's.


Author(s):  
G. Anand ◽  
C. B. Panchal ◽  
D. C. Erickson

The gas-fired Generator-Absorber heat eXchanger (GAX) heat pump is being considered for space conditioning in residential and light commercial applications. In order to meet the national building codes for ammonia absorption heat pumps, a secondary fluid is used to interface with the air-coils. Proper choice of a secondary fluid maximizes the economic advantage of the GAX heat pump. The secondary fluid transfers the heating and cooling loads from the absorption heat pump to and from outdoor and indoor air-coils. The physical properties of secondary fluids influence the heat transfer performance in the heat-exchange equipment and hence the effective lift, thereby determining the cycle coefficient of performance (COP). Additionally, the pumping power for each fluid varies depending on the density and viscosity at operating temperatures. The variation in cycle COP and pumping power as a result of fluid properties is ultimately manifested as changes in electric and natural-gas cost. An analysis was carried out to evaluate six secondary fluids for a GAX absorption heat pump. A performance model was developed to simulate the secondary-fluid flow loops and the absorption heat pump. The utility costs for heating and cooling were determined for a typical building. The effects of ambient conditions and local utility rates were determined by modeling the annual utility costs in four cities: Atlanta, Chicago, Los Angeles, and New York. These four cities provided wide variations in heating and cooling requirements, and utility rates for natural gas and electricity. The results from this study provide a basis for selecting secondary fluids for heat pumping in different locations.


2012 ◽  
Vol 238 ◽  
pp. 478-481
Author(s):  
Zhen Qing Wang ◽  
Yan Chen ◽  
Hai Xia Wang

An air source heat pump system (ASHPS) was set up, which provided space heating and cooling, as well as hot water for an office building in Tianjin. Its operating performance in winter was evaluated based on test data. Considering the local abundant solar radiation and the way to provide energy in an office building, a simulation study was carried out on the combsystem of ASHP and flat plate air collector (FPAC). The effects of collector area and its outlet parameters on the heating performance of ASHP were studied, and the favorable operating and matching mode were recommended. The results indicate that ASHPS is a technically viable method in Tianjin in winter, but not economically, and the air-solar combsystem should be taken into account for its massive replacement for conventional energy.


Author(s):  
Jenny Chu ◽  
Cynthia A. Cruickshank

Heat pumps are commonly used for space-heating and cooling requirements. The combination of solar thermal and heat pump systems as a single solar-assisted heat pump (SAHP) system is a promising technology for offsetting domestic hot water, space-heating and cooling loads more efficiently. Task 44 of the Solar Heating and Cooling Programme of the International Energy Agency is currently investigating ways to optimize SAHP systems for residential use. This paper presents a review of past and current work conducted on SAHP systems. Specifically, the key performance data from many studies are highlighted and different system configurations are compared in order to establish insight towards which system configurations are suitable for the Canadian residential sector. It was found that the most suitable configuration for Canadian residential buildings depend on a combination of factors which may include occupant behavior, building characteristics, operation parameters, system components, the performance criteria of interest and climate. A large variety of configurations and parameters exist for SAHP systems and this made analyzing a specific system, comparing differing systems and establishing an optimal design fairly difficult. It was found that different authors used various different performance criterions and this inconsistency also added to the difficulty of comparing the studies of different systems. Overall, a standard performance criterion needs to be established for SAHP systems in order to meaningfully compare different configurations and determine optimal configurations for certain requirements.


2021 ◽  
pp. 1-32
Author(s):  
Bismark Addo-Binney ◽  
Wahid Besada ◽  
Martin Agelin-Chaab

Abstract This paper performed analyses on a proposed direct wind-powered heat pump integrated with a pond which serves as an evaporator for space heating in cold regions. The analysis was conducted using environmental data for selected locations in Canada and the Engineering Equation Solver. Three different pairings of heat pumps and wind turbines were studied (a wind-powered heat pump with a pond as an evaporator, a wind-powered heat pump without a pond, and an electricity-powered heat pump). Energy and exergy analyses were performed on the systems. The novelty in the present study is in the use of a wind turbine to directly power the heat pump and using a pond as the evaporator. The results show that the proposed system has the highest coefficient of performance compared to the others. The average coefficient of performance for the selected locations is 2.7, which is at least 67% better than the others. Similarly, the overall exergy for the proposed system is 16.9%, which is at least 40% better than the others. The average heating capacity of the selected locations for the proposed system is 4.5 kW, which is from 29% to 300% better than the others. Additionally, the sustainability index for the proposed system is the highest for the proposed system. The results have shown that the proposed system has superior overall performance for space heating in cold regions.