Numerical Analysis of a Single Minichannel Within a High-Temperature Hydrogen Heat Exchanger for Beamed Energy Propulsion Applications

Author(s):  
Daniel W. Gould ◽  
Brad W. Hoff ◽  
Marcus P. Young ◽  
Rebecca N. Webb

The requirement that the propellants used in launch vehicle systems must also provide the thermal energy to be converted to kinetic energy in the rocket nozzle has plagued rocket designers since the dawn of the space age. Beamed propulsion systems, however, avoid this constraint by placing the energy source on the ground and transmitting the energy to the spacecraft via microwaves. This computational work evaluates three different heat exchanger channel designs for use in a beam propulsion spacecraft. The working fluid was hydrogen and the input energy was 1.3 kW. The increase in axial temperature along the 0.1 m long channel was as high as 2000 K. In addition, it was found that despite the very small diameter of the minichannels, 1 mm, each design produced extreme temperature gradients across the channel cross section. These temperature gradients affected the velocity profile; the maximum velocity was not located at the channel center.

2021 ◽  
Vol 9 (1) ◽  
Author(s):  
Hannah R. Doran ◽  
Theo Renaud ◽  
Gioia Falcone ◽  
Lehua Pan ◽  
Patrick G. Verdin

AbstractAlternative (unconventional) deep geothermal designs are needed to provide a secure and efficient geothermal energy supply. An in-depth sensitivity analysis was investigated considering a deep borehole closed-loop heat exchanger (DBHE) to overcome the current limitations of deep EGS. A T2Well/EOS1 model previously calibrated on an experimental DBHE in Hawaii was adapted to the current NWG 55-29 well at the Newberry volcano site in Central Oregon. A sensitivity analysis was carried out, including parameters such as the working fluid mass flow rate, the casing and cement thermal properties, and the wellbore radii dimensions. The results conclude the highest energy flow rate to be 1.5 MW, after an annulus radii increase and an imposed mass flow rate of 5 kg/s. At 3 kg/s, the DBHE yielded an energy flow rate a factor of 3.5 lower than the NWG 55-29 conventional design. Despite this loss, the sensitivity analysis allows an assessment of the key thermodynamics within the wellbore and provides a valuable insight into how heat is lost/gained throughout the system. This analysis was performed under the assumption of subcritical conditions, and could aid the development of unconventional designs within future EGS work like the Newberry Deep Drilling Project (NDDP). Requirements for further software development are briefly discussed, which would facilitate the modelling of unconventional geothermal wells in supercritical systems to support EGS projects that could extend to deeper depths.


2013 ◽  
Vol 2013 ◽  
pp. 1-10 ◽  
Author(s):  
R. Mazón-Hernández ◽  
J. R. García-Cascales ◽  
F. Vera-García ◽  
A. S. Káiser ◽  
B. Zamora

The main priority in photovoltaic (PV) panels is the production of electricity. The transformation of solar energy into electricity depends on the operating temperature in such a way that the performance increases with the decreasing temperatures. In the existing literature, different cooling techniques can be found. The purpose of most of them is to use air or water as thermal energy carriers. This work is focused on the use of air as a working fluid whose movement is either induced by natural convection or forced by means of a fan. The aim of this study is to characterise the electrical behaviour of the solar panels in order to improve the design of photovoltaic installations placed in roof applications ensuring low operating temperatures which will correct and reverse the effects produced on efficiency by high temperature. To do this, a test installation has been constructed at the Universidad Politécnica de Cartagena in Spain. In this paper, the results of the tests carried out on two identical solar panels are included. One of them has been modified and mounted on different channels through which air flows. The different studies conducted show the effects of the air channel cross-section, the air velocity, and the panel temperature on the electrical parameters of the solar panels, such as the voltage, current, power, and performance. The results conclude that the air space between the photovoltaic panels and a steel roof must be high enough to allow the panel to be cooled and consequently to achieve higher efficiency.


2021 ◽  
Author(s):  
Anthony Clark ◽  
Tiziana Vanorio ◽  
Andrey Radostin ◽  
Vladimir Zaitsev

<p>An understanding of micro- and macrofracture behavior in low porosity rocks is pertinent to several areas of energy and environmental science such as petroleum production, carbon sequestration, and enhancement of technologies based on geothermal energy, etc. For example, the carbonate reservoirs in dolomitic or micritic formations with matrix porosities below 6% suggest the importance of fracture-augmented permeability in production. Similarly, hydrocarbons have been found on nearly every continent in tight basement rocks, all of which have little matrix porosity and their permeability therefore rely solely on hydraulic connectivity from fractures. For geothermal energy, various igneous and sedimentary rocks (granites, basalts, and limestones) are being exploited across the globe, with some of the lowest porosity and permeability. In all these cases, fractures are necessary to improve rock permeability and thermal exchange between the rock and working fluid, which can be enabled by hydraulic stimulation, as well as by secondary cracking due to extreme temperature gradients from the injection of cold water. The fracture geometry, density, and distribution all together control not only fluid and thermal transport in the rocks, but also their seismic attributes that can be used to extract information about the fractures. <br>In order to accurately interpret the seismo-acoustic data (usually, the velocities of compression and shear waves) reliable rock physics models are required. Here, we report the results of interpretation of such experimental data for both as-cored rock samples and those subjected to thermo-hydro-chemo-mechanical damage (THCMD) in the laboratory. For interpretation, we use a convenient model of fractured rock in which fractures are represented as planar defects with decoupled shear and normal compliances. The application of such an approach makes it possible to assess and compare the elastic properties of fractures in the rocks before and after application of THCMD procedures. For the analyzed samples of granites, basalts, and limestones it has been found that for a significant portion of rocks, the ratio of normal-to-shear compliances of cracks significantly differ from the value typical of conventionally assumed penny-shape cracks. Furthermore, for some samples, this ratio appears to be noticeably different for fractures existing in the as-cored rock and arising in the same rock after THCMD procedures. These results indicate that damage to a rock typically changes its compliance ratio since the old and new cracks are likely to have different elastic properties. Our results are also consistent with the notion that a specific damage process occurring for a given microstructure will consistently create cracks with a particular set of elastic properties. The proposed methodology for assessment of elastic properties of cracks in rock samples subjected to thermo-hydro-chemo-mechanical damage has given previously inaccessible useful information about the elastic properties of fractures and can be extended to interpretation of seismic attributes of rocks for a broad range of other applications.</p>


Author(s):  
Hyungki Shin ◽  
Junhyun Cho ◽  
Young-Jin Baik ◽  
Jongjae Cho ◽  
Chulwoo Roh ◽  
...  

Power generation cycle — typically Brayton cycle — to use CO2 at supercritical state as working fluid have been researched many years because this cycle increase thermal efficiency of cycle and decrease turbomachinery size. But small turbomachinery make it difficult to develop proto type Supercritical Carbon dioxide (S-CO2) cycle equipment of lab scale size. KIER (Korea Institute of Energy Research) have been researched S-CO2 cycle since 2013. This paper is about 60kWe scale and sub-kWe class turbo generator development for applying to this S-CO2 cycle at the lab scale. A design concept of this turbo-generator is to use commercially available components so as to reduce development time and increase reliability. Major problem of SCO2 turbine is small volume flow rate and huge axial force. High density S-CO2 was referred as advantage of S-CO2 cycle because it make small turbomachinery possible. But this advantage was not valid in lab-scale cycles under 100kW because small amount volume flow rate means high rotating speed and too small diameter of turbine to manufacture it. Also, high inlet and outlet pressure make huge axial force. To solve these problem, KIER have attempt various turbines. In this paper, these attempts and results are presented and discussed.


Author(s):  
Masahiro Osakabe

The most part of energy losses in power system such as fuel cells is due to the heat released by the exhaust gas to atmosphere. The exhaust gas consists of non-condensable gas and steam with sensible and latent heat. As a lot of latent heat is included in the exhaust gas, its recovery is very important to improve the power system efficiency. Based on the previous basic studies, a thermal hydraulic prediction method for latent heat recovery exchangers was proposed. For the condensation of steam on heat transfer tubes, the modified Sherwood number taking account of the mass absorption effect on the wall was used. Two kinds of compact heat exchanger with staggered banks of bare tubes of 10.5 or 4mm in outer diameter was designed with the prediction method. The more compactness was obtained with the smaller tubes at a designed heat recovery. The thermal hydraulic behavior in the compact heat exchangers was experimentally studied with air-steam mixture gas. In the parametric experiments varying the steam mass concentration, the temperature distributions of cooling water and mixture gas were measured. The experimental results agreed well with the prediction proposed in this study and the more compactness with the smaller tubes was proved.


2015 ◽  
Vol 76 (11) ◽  
Author(s):  
Muhammad Nuriyadi ◽  
Sumeru Sumeru ◽  
Henry Nasution

This study presents the effect of liquid-suction heat exchangers (LSHX) sub-cooler in a freezer. The LSHX sub-cooler is a method to increase the cooling capacity of the evaporator by lowering temperature at the condenser outlet. The decrease in temperature of the condenser outlet will cause a decrease in the quality refrigerant entering the evaporator. The lower the quality of the refrigerant entering the evaporator, the higher the cooling capacity produced by the evaporator. The LSHX sub-cooler utilizes a heat exchanger to transfer heat from the outlet of the condenser (liquid line) to the suction of the compressor. In the present study, three different LSHX sub-coolers in the freezer with cabin temperature settings of 0, -10 and -20oC were investigated. The results showed that the lowest and the highest of effectiveness of the heat exchanger were 0.28 and 0.58, respectively. The experimental results also showed that EER reduction is occurred at the cabin temperature setting of 0oC and -10oC, whereas the EER improvements were always occurred at the cabin temperature settings of -20oC.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.


2020 ◽  
pp. 1-34
Author(s):  
Matthew Carlson ◽  
Francisco Alvarez

Abstract A new generation of Concentrating Solar Power (CSP) technologies is under development to provide dispatchable renewable power generation and reduce the levelized cost of electricity (LCOE) to 6 cents/kWh by leveraging heat transfer fluids (HTF) capable of operation at higher temperatures and coupling with higher efficiency power conversion cycles. The U.S. Department of Energy (DOE) has funded three pathways for Generation 3 CSP (Gen3CSP) technology development to leverage solid, liquid, and gaseous HTFs to transfer heat to a supercritical carbon dioxide (sCO2) Brayton cycle. This paper presents the design and off-design capabilities of a 1 MWth sCO2 test system that can provide sCO2 coolant to the primary heat exchangers (PHX) coupling the high-temperature HTFs to the sCO2 working fluid of the power cycle. This system will demonstrate design, performance, lifetime, and operability at a scale relevant to commercial CSP. A dense-phase high pressure canned motor pump is used to supply up to 5.3 kg/s of sCO2 flow to the primary heat exchanger at pressures up to 250 bar and temperatures up to 715 °C with ambient air as the ultimate heat sink. Key component requirements for this system are presented in this paper.


Coatings ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 1051
Author(s):  
Kun Liu ◽  
Xi Chen ◽  
Kangping Du ◽  
Yu Wang ◽  
Jinguang Du ◽  
...  

The purpose of this paper is to study the thermal shock resistance and failure mechanism of La2Ce2O7/8YSZ double-ceramic-layer thermal barrier coatings (LC/8YSZ DCL TBCs) under extreme temperature gradients. At high surface temperatures, thermal shock and infrared temperature measuring modules were used to determine the thermal cycling life and insulation temperature of LC/8YSZ DCL TBCs under extreme temperature gradients by an oxygen–acetylene gas flame testing machine. A viscoelastic model was used to obtain the stress and strain law of solid phase sintering of a coating system using the finite element method. Results and Conclusion: (1) Thermal cycling life was affected by the surface temperature of LC/8YSZ DCL TBCs and decreased sharply with the increase of surface temperature. (2) The LC ceramic surface of the failure coating was sintered, and the higher the temperature, the faster the sintering process. (3) Accelerated life test results showed that high temperature thermal cycling life is not only related to thermal fatigue of ceramic layer, but is also related to the sintering degree of the coating. (4) Although the high temperature thermal stress had great influence on the coating, great sintering stress was produced with sintering of the LC ceramic layer, which is the main cause of LC/8YSZ DCL TBC failure. The above results indicate that for new TBC ceramic materials, especially those for engines above class F, their sinterability should be fully considered. Sintering affects the thermal shock properties at high temperature. Our research results can provide reference for material selection and high temperature performance research.


Sign in / Sign up

Export Citation Format

Share Document