Study of the Effect of Turbulence Promoters in Circular Cooling Channels

Author(s):  
N. Cristobal Uzarraga-Rodriguez ◽  
Armando Gallegos-Mun˜oz ◽  
J. Cuauhtemoc Rubio-Arana ◽  
Alfonso Campos-Amezcua ◽  
Mazur Zdzislaw

A numerical analysis of a gas turbine first stage bucket with internal cooling (model MS7001E) is presented. The internal cooling system consists of 13 cylindrical channels with turbulent promoters (ribs), which are implemented in order to achieve temperature decrements inside the body blade. Three different geometrics (square, triangular and semi-circular cross-section) are studied. Each configuration is analyzed having full or half ribs. These are placed inside the cooling channels. The effects generated by the aspect ratio variation between rib pitch and rib height (P/e), for a constant aspect ratio given by ribs height and hydraulic diameter (e/Dh) are considered. The numerical simulation was developed using finite volume method, by means of commercial software based on computational fluid dynamics (CFD). Each one of the models generated for each study case was built in a 3D model, including the platform and airfoil of the blade. The models consider the effects generated by the hot combustion gases are flowing around the blade and the coolant flow is flowing inside the cooling channels. The study includes the solution of the conjugate heat transfer. The results show that the cooling channels with squared and triangular full-ribs present better cooling effects inside the body blade, reducing the temperature until 10°C at some point in the blade. However, these configurations produce a pressure drop from 3 to 4 times higher than cooling channels without ribs. The half ribs produce lesser temperature decrement, having smaller pressure drop. On other hand, the aspect ratio (P/e) has only effects on the pressure drop.

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3954
Author(s):  
Liang Xu ◽  
Qicheng Ruan ◽  
Qingyun Shen ◽  
Lei Xi ◽  
Jianmin Gao ◽  
...  

Traditional cooling structures in gas turbines greatly improve the high temperature resistance of turbine blades; however, few cooling structures concern both heat transfer and mechanical performances. A lattice structure (LS) can solve this issue because of its advantages of being lightweight and having high porosity and strength. Although the topology of LS is complex, it can be manufactured with metal 3D printing technology in the future. In this study, an integral optimization model concerning both heat transfer and mechanical performances was presented to design the LS cooling channel with a variable aspect ratio in gas turbine blades. Firstly, some internal cooling channels with the thin walls were built up and a simple raw of five LS cores was taken as an insert or a turbulator in these cooling channels. Secondly, relations between geometric variables (height (H), diameter (D) and inclination angle(ω)) and objectives/functions of this research, including the first-order natural frequency (freq1), equivalent elastic modulus (E), relative density (ρ¯) and Nusselt number (Nu), were established for a pyramid-type lattice structure (PLS) and Kagome-type lattice structure (KLS). Finally, the ISIGHT platform was introduced to construct the frame of the integral optimization model. Two selected optimization problems (Op-I and Op-II) were solved based on the third-order response model with an accuracy of more than 0.97, and optimization results were analyzed. The results showed that the change of Nu and freq1 had the highest overall sensitivity Op-I and Op-II, respectively, and the change of D and H had the highest single sensitivity for Nu and freq1, respectively. Compared to the initial LS, the LS of Op-I increased Nu and E by 24.1% and 29.8%, respectively, and decreased ρ¯ by 71%; the LS of Op-II increased Nu and E by 30.8% and 45.2%, respectively, and slightly increased ρ¯; the LS of both Op-I and Op-II decreased freq1 by 27.9% and 19.3%, respectively. These results suggested that the heat transfer, load bearing and lightweight performances of the LS were greatly improved by the optimization model (except for the lightweight performance for the optimal LS of Op-II, which became slightly worse), while it failed to improve vibration performance of the optimal LS.


Author(s):  
Daniel Lo¨rstad

The main parts of the annular combustor liner walls of the Siemens gas turbine SGT-800 are convectively cooled using rib turbulated cooling. Due to the serial system of cooling and combustion air there is a potential of further reduction of total combustor pressure drop by improvements of the cooling system. Apart from the rib cooling, also the cooling channel bypass entrance is related to a significant part of the total cooling system pressure drop. In this study, an investigation is performed for a rib cooled channel which is related to the considered combustor liner and where empirical correlations are available in order to evaluate the methodology used. The study includes an assessment of the Reynolds Averaged Navier-Stokes (RANS) and Large Eddy Simulation (LES) models available within commercial Computational Fluid Dynamics (CFD) codes and includes also an investigation of model size when using periodic boundaries for LES simulations. It is well known that a small geometrical distance in the direction of the periodic boundaries may have a strong effect on the flow field but is often neglected in practice in order to speed up LES calculations. Here the effect is assessed in order to show what size is required for accurate results, both for time averaged and transient results. In addition too small domains may be affected by spurious low frequencies originating from the periodic boundaries requiring additional simulation time for time converged statistics, but also the averages may be significantly affected. In addition the simulation period for time converged statistics is evaluated in order to show that larger model size in the periodic direction does not necessarily require longer practical simulation time, due to the fact that larger volumes may be used for the combined time and space averaging. The aim is to obtain practical guidelines for LES calculations for internal cooling flows. Then the study is extended step by step to investigate the importance due to high Reynolds number, variable fluid properties and large temperature gradients in order to cover the ranges and specifics required for SGT-800 engine conditions.


Author(s):  
Shinjan Ghosh ◽  
Jayanta S. Kapat

Abstract Gas Turbine blade cooling is an important topic of research, as a high turbine inlet temperature (TIT) essentially means an increase in efficiency of gas turbine cycles. Internal cooling channels in gas turbine blades are key to the cooling and prevention of thermal failure of the material. Serpentine channels are a common feature in internal blade cooling. Optimization methods are often employed in the design of blade internal cooling channels to improve heat-transfer and reduce pressure drop. Topology optimization uses a variable porosity approach to manipulate flow geometries by adding or removing material. Such a method has been employed in the current work to modify the geometric configuration of a serpentine channel to improve total heat transferred and reduce the pressure drop. An in-house OpenFOAM solver has been used to create non-traditional geometries from two generic designs. Geometry-1 is a 2-D serpentine passage with an inlet and 4 bleeding holes as outlets for ejection into the trailing edge. Geometry-2 is a 3-D serpentine passage with an aspect ratio of 3:1 and consists of two 180-degree bends. The inlet velocity for both the geometries was used as 20 m/s. The governing equations employ a “Brinkman porosity parameter” to account for the porous cells in the flow domain. Results have shown a change in shape of the channel walls to enhance heat-transfer in the passage. Additive manufacturing can be employed to make such unconventional shapes.


Author(s):  
Izzet Sahin ◽  
Andrew F. Chen ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han ◽  
Robert Krewinkel

Abstract The internal cooling passages of gas turbine blades mostly have varying aspect ratios from one passage to another. However, there are limited data available in the open literature that used a reduced cross-section and aspect ratio, AR, after the tip turn. Therefore, the current study presents heat transfer and pressure drop of three different α = 45° profiled rib orientations, typical parallel (usual), reversed parallel (unusual), and criss-cross patterns in a rotating two-pass rectangular channel with AR = 4:1 and 2:1 in the first radially outward flow and second radially inward flow passages respectively. For each rib orientation, regional averaged heat transfer results are obtained for both the flow passages with the Reynolds number ranging from 10,000 to 70,000 for the first passage and 16000 to 114000 for the second passage with a rotational speed range of 0 rpm to 400 rpm. This results in the highest rotation number of 0.39 and 0.16 for the first and second passage respectively. The effects of rib orientation, aspect ratio variation, 180° tip turn, and rotation number on the heat transfer and pressure drop will be addressed. According to the results, for usual, unusual and criss-cross rib patterns, increasing rotation number causes the heat transfer to decrease on the leading surface and increase on the trailing surface for the first passage and vice versa for the second passage. Overall heat transfer enhancement of the usual and unusual rib patterns is higher than criss-cross one. In terms of the pressure losses, the criss-cross rib pattern has the lowest and the usual rib pattern has the highest-pressure loss coefficients. When pressure loss and heat transfer enhancement are both taken into account together, the criss-cross or unusual rib pattern might be an option to use in the internal cooling method. Therefore, the results can be useful for turbine blade internal cooling design and heat transfer analysis.


Author(s):  
Metapun Nuntakulamarat ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

Abstract This paper focuses on the measurements of heat transfer enhancement and pressure drop of different pin or fin configurations in a high aspect ratio (AR = 9.57/1.2) channel. Two different pin-fin shapes including circular pins and strip fins were studied. Different pin-fin spacings for circular pins (S/D = 2, 4) and strip fins (S/W = 8, 16) were investigated, respectively. In addition, the thickness effect of the strip fin was included in this study. The regionally averaged heat transfer measurement method was used to acquire the heat transfer coefficients on two opposite featured surfaces within the test channel. For each configuration, the tested Reynolds number was ranging from 20,000 to 80,000. The results indicate that the channel with circular pins has better heat transfer enhancement and higher pressure loss than their strip fins counterparts. However, the strip fins are considered better designs in terms of thermal performance. For the gas turbine designers aim at developing an improved internal cooling feature, this work demonstrates the great potential of the strip fins as a novel and effective cooling design compared with the conventional circular pins.


2020 ◽  
Vol 142 (7) ◽  
Author(s):  
Izzet Sahin ◽  
Andrew F Chen ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han ◽  
Robert Krewinkel

Abstract The internal cooling passages of gas turbine blades mostly have varying aspect ratios from one passage to another. However, there are limited data available in the open literature that used a reduced cross section and aspect ratio (AR), after the tip turn. Therefore, the current study presents heat transfer and pressure drop of three different α = 45 deg profiled rib orientations, typical parallel (usual), reversed parallel (unusual), and crisscross patterns in a rotating two-pass rectangular channel with AR = 4:1 and 2:1 in the first radially outward flow and second radially inward flow passages, respectively. For each rib orientation, regional averaged heat transfer results are obtained for both the flow passages with the Reynolds number ranging from 10,000 to 70,000 for the first passage and 16,000 to 114,000 for the second passage with a rotational speed range of 0–400 rpm. This results in the highest rotation number of 0.39 and 0.16 for the first and second passage respectively. The effects of rib orientation, aspect ratio variation, 180-deg tip turn, and rotation number on the heat transfer and pressure drop will be addressed. According to the results, for usual, unusual and crisscross rib patterns, increasing rotation number causes the heat transfer to decrease on the leading surface and increase on the trailing surface for the first passage and vice versa for the second passage. The overall heat transfer enhancement of the usual and unusual rib patterns is higher than the crisscross one. In terms of the pressure losses, the crisscross rib pattern has the lowest and the usual rib pattern has the highest-pressure loss coefficients. When pressure loss and heat transfer enhancement are both taken into account together, the crisscross or unusual rib pattern might be an option to use in the internal cooling method. Therefore, the results can be useful for the turbine blade internal cooling design and heat transfer analysis.


Author(s):  
Hans-Jörg Dennig ◽  
Livia Zumofen ◽  
Daniel Stierli ◽  
Andreas Kirchheim ◽  
Simon Winterberg

AbstractThe layer-by-layer principle of the additive manufacturing (AM) technology of Laser-Powder-Bed-Fusion (LPBF) creates new opportunities in the design and manufacturing of efficient gear components. For example, integrating a cooling system can increase the safety against scuffing or reduce the amount of required lubrication and thus the splashing losses. Quenched and tempered steels or case-hardened steels are commonly used in the fabrication of gear components. However, the availability of these alloys for LPBF processing is still limited. The development of suitable LPBF metal gears (with a Gear Research Centre (FZG) type A geometry) out of quenched and tempered 30CrNiMo8 steel with internal cooling channels shows the possibility of significantly increasing the safety factor against scuffing. This work includes the development of a suitable cooling strategy, material development, the setup of a suitable test infrastructure and the analysis of the LPBF gears tested for scuffing.


Author(s):  
Tom Verstraete ◽  
Filippo Coletti ◽  
Je´re´my Bulle ◽  
Timothe´e Vanderwielen ◽  
Tony Arts

This two-parts paper addresses the design of a U-bend for serpentine internal cooling channels optimized for minimal pressure loss. The total pressure loss for the flow in a U-bend is a critical design parameter as it augments the pressure required at the inlet of the cooling system, resulting in a lower global efficiency. In this first part of the paper the design methodology of the cooling channel is presented. The minimization of the total pressure loss is achieved by means of a numerical optimization method that uses a metamodel assisted differential evolution algorithm in combination with an incompressible Navier-Stokes solver. The profiles of the internal and external side of the bend are parameterized using piece-wise Bezier curves. This allows for a wide variety of shapes, respecting the manufacturability constraints of the design. The pressure loss is computed by the Navier-Stokes solver, which is based on a two-equation turbulence model and is available from the open source software OpenFOAM. The numerical method predicts an improvement of 36% in total pressure drop with respect to a circular U-bend, mainly due to the reduction of the separated flow region along the internal side of the bend. The resulting design is subjected to experimental validation, presented in Part II of the paper.


2000 ◽  
Author(s):  
Snezana Konecni ◽  
Nathan K. Bultman

Abstract Water flow in cooling channels was simulated using the computational fluid dynamics (CFD) code CFX4. Pressure drop in the cooling channels of the coupled-cavity linac (CCL) cavity was calculated. The effects of the manifold on the pressure drop were studied also. Reducing the pressure drop was a primary goal of this exercise that led to changing the cooling channel entrance regions. Results of this analysis were used in sizing pumps required for the cooling system. For the validation of the simplified numerical model, an experiment was performed to measure the pressure drop in the cooling channels for variable flow rate, using a flow loop. Deionized water was circulated through the test section with a pump and its flow rate was monitored with a turbine flow meter. Pressure was monitored with pressure transducers at five locations including a differential pressure transducer across the test section, and water temperature was taken at the exit of the pump. Pressure drop across the inlet and outlet of the test section was measured and recorded for different flow rates. Flow rate was also monitored and stored simultaneously. From the recorded data, an empirical correlation was derived to describe the pressure drop, dp, as a function of flow rate through the four cooling channels.