Effects of Rotor Tip Clearance on Tip Clearance Flow Potentially Leading to NSV in an Axial Compressor

Author(s):  
Hong-Sik Im ◽  
Ge-Cheng Zha

This paper investigates non-synchronous vibration (NSV) mechanism of a high-speed axial compressor with three different rotor tip clearances. Numerical simulations for 1/7th annulus periodic sector are performed using an unsteady Reynolds-averaged Navier-Stokes(URANS) solver with a fully conservative sliding boundary condition to capture wake unsteadiness between the rotor and stator blades. The simulated NSV shows that the frequency and amplitude are strongly influenced by the tip clearance size and shape. The predicted NSV frequency is in good agreement with the experiment. The maximum amplitude of the NSV occurs at about 78% span of the rotor suction leading edge regardless of tip clearance due to a strong interaction of incoming flow, tip leakage flow and tip vortex. The instability of tornado like tip vortex oscillating in streamwise direction appears to be the main cause of the NSV observed in this study.

Author(s):  
Matthew A. Bennington ◽  
Mark H. Ross ◽  
Joshua D. Cameron ◽  
Scott C. Morris ◽  
Juan Du ◽  
...  

A numerical and experimental study was conducted to investigate the tip clearance flow and its relationship to stall in a transonic axial compressor. The CFD results were used to identify the existence of an interface between incoming axial flow and the reverse tip clearance flow. A surface streaking method was used to experimentally identify this interface as a line of zero axial shear stress at the casing. The position of this line, denoted xzs, moved upstream with decreasing flow coefficient in both the experiments and computations. The line was found to be at the rotor leading edge plane when the compressor stalled. Further measurements using rotor offset and inlet distortion further corroborated these results, and demonstrated that the movement of the interface upstream of the leading edge leads to the generation of rotating (“spike”) disturbances. Stall was therefore interpreted to occur as a result of a critical momentum balance between the approach fluid and the tip-leakage flow.


2016 ◽  
Vol 138 (12) ◽  
Author(s):  
Du Juan ◽  
Li Jichao ◽  
Gao Lipeng ◽  
Lin Feng ◽  
Chen Jingyi

In this study, the impact of single grooves at different locations on compressor stability and tip clearance flow are numerically and experimentally investigated. Initially, the numerical stall margin improvement (SMI) curve is examined using experimental data. Then, the evolution of the interface between the tip leakage flow (TLF) and the incoming main flow (MF) in the prestall and stall inception processes for two typical grooves, i.e., the worst and the optimal grooves in terms of their SMI, are compared with the smooth casing. The results show two different interface behaviors throughout the throttling process. The compressor with the worst single groove casing first experiences a long-length-scale disturbance after the interface near the blade suction side spills in front of the rotor leading-edge plane, and then goes through spikes after the whole interface spills. With the smooth casing and the optimal single groove near midchord, the interface reaches the rotor leading edge at the last stable operating point and spikes appear once the whole interface spills over the rotor leading edge. A model that illustrates the spillage patterns of the interface for the two stall precursors is thus proposed accordingly and used to explain their effectiveness in terms of the SMI. At last, the relevance of these results to the preliminary selection of groove locations for multigroove casing treatments (CTs) is verified by test data and discussed.


Author(s):  
José Ramón Serrano ◽  
Roberto Navarro ◽  
Luis Miguel García-Cuevas ◽  
Lukas Benjamin Inhestern

Tip leakage loss characterization and modeling plays an important role in small size radial turbine research. The momentum of the flow passing through the tip gap is highly related with the tip leakage losses. The ratio of fluid momentum driven by the pressure gradient between suction side and pressure side and the fluid momentum caused by the shroud friction has been widely used to analyze and to compare different sized tip clearances. However, the commonly used number for building this momentum ratio lacks some variables, as the blade tip geometry data and the viscosity of the used fluid. To allow the comparison between different sized turbocharger turbine tip gaps, work has been put into finding a consistent characterization of radial tip clearance flow. Therefore, a non-dimensional number has been derived from the Navier Stokes Equation. This number can be calculated like the original ratio over the chord length. Using the results of wide range CFD data, the novel tip leakage number has been compared with the traditional and widely used ratio. Furthermore, the novel tip leakage number can be separated into three different non-dimensional factors. First, a factor dependent on the radial dimensions of the tip gap has been found. Second, a factor defined by the viscosity, the blade loading, and the tip width has been identified. Finally, a factor that defines the coupling between both flow phenomena. These factors can further be used to filter the tip gap flow, obtained by CFD, with the influence of friction driven and pressure driven momentum flow.


Author(s):  
Chunill Hah

Effects of axial casing grooves (ACGs) on the stall margin and efficiency of a one and a half stage low-speed axial compressor with a large rotor tip gap are investigated in detail. The primary focus of the current paper is to identify the flow mechanisms behind the changes in stall margin and on the efficiency of the compressor stage with a large rotor tip gap. Semicircular axial grooves installed in the rotor’s leading edge area are investigated. A large eddy simulation (LES) is applied to calculate the unsteady flow field in a compressor stage with ACGs. The calculated flow fields are first validated with previously reported flow visualizations and stereo PIV (SPIV) measurements. An in-depth examination of the calculated flow field indicates that the primary mechanism of the ACG is the prevention of full tip leakage vortex (TLV) formation when the rotor blade passes under the axial grooves periodically. The TLV is formed when the incoming main flow boundary layer collides with the tip clearance flow boundary layer coming from the opposite direction near the casing and rolls up around the rotor tip vortex. When the rotor passes directly under the axial groove, the tip clearance flow boundary layer on the casing moves into the ACGs and no roll-up of the incoming main flow boundary layer can occur. Consequently, the full TLV is not formed periodically as the rotor passes under the open casing of the axial grooves. Axial grooves prevent the formation of the full TLV. This periodic prevention of the full TLV generation is the main mechanism explaining how the ACGs extend the compressor stall margin by reducing the total blockage near the rotor tip area. Flows coming out from the front of the grooves affect the overall performance as it increases the flow incidence near the leading edge and the blade loading with the current ACGs. The primary flow mechanism of the ACGs is periodic prevention of the full TLV formation. Lower efficiency and reduced pressure rise at higher flow rates for the current casing groove configuration are due to additional mixing between the main passage flow and the flow from the grooves. At higher flow rates, blockage generation due to this additional mixing is larger than any removal of the flow blockage by the grooves. Furthermore, stronger double-leakage tip clearance flow is generated with this additional mixing with the ACGs at a higher flow rate than that of the smooth wall.


Author(s):  
Chunill Hah ◽  
Michael Hathaway ◽  
Joseph Katz

The primary focus of this paper is to investigate the effect of rotor tip gap size on how the rotor unsteady tip clearance flow structure changes in a low speed one and half stage axial compressor at near stall operation (for example, where maximum pressure rise is obtained). A Large Eddy Simulation (LES) is applied to calculate the unsteady flow field at this flow condition with both a small and a large tip gaps. The numerically obtained flow fields at the small clearance matches fairly well with the available initial measurements obtained at the Johns Hopkins University with 3-D unsteady PIV in an index-matched test facility which renders the compressor blades and casing optically transparent. With this setup, the unsteady velocity field in the entire flow domain, including the flow inside the tip gap, can be measured. The numerical results are also compared with previously published measurements in a low speed single stage compressor (Maerz et al. [2002]). The current study shows that, with the smaller rotor tip gap, the tip clearance vortex moves to the leading edge plane at near stall operating condition, creating a nearly circumferentially aligned vortex that persists around the entire rotor. On the other hand, with a large tip gap, the clearance vortex stays inside the blade passage at near stall operation. With the large tip gap, flow instability and related large pressure fluctuation at the leading edge are observed in this one and a half stage compressor. Detailed examination of the unsteady flow structure in this compressor stage reveals that the flow instability is due to shed vortices near the leading edge, and not due to a three-dimensional separation vortex originating from the suction side of the blade, which is commonly referred to during a spike-type stall inception. The entire tip clearance flow is highly unsteady. Many vortex structures in the tip clearance flow, including the sheet vortex system near the casing, interact with each other. The core tip clearance vortex, which is formed with the rotor tip gap flows near the leading edge, is also highly unsteady or intermittent due to pressure oscillations near the leading edge and varies from passage to passage. For the current compressor stage, the evidence does not seem to support that a classical vortex breakup occurs in any organized way, even with the large tip gap. Although wakes from the IGV influence the tip clearance flow in the rotor, the major characteristics of rotor tip clearance flows in isolated or single stage rotors are observed in this one and a half stage axial compressor.


1998 ◽  
Author(s):  
E. S. Politis ◽  
K. C. Giannakoglou ◽  
K. D. Papailiou

Innovative measurements of tip-clearance flow for the 3rd stage rotor embedded in a four stage Low-Speed Research Compressor are presented in the companion ASME paper. Here, in Part 2, the rotor flow is numerically simulated through a Navier-Stokes solver implementing the k-ε turbulence model. The 3rd stage rows are considered as discrete parts of the same computational domain and the flow in each one of them is treated as steady in the corresponding system of reference. An iterative, though loose, coupling between the rotor exit and the stator inlet is established by artificially increasing the inter-row distance. To model tip-clearance flow effects with sufficient accuracy, a two-block grid system per row is used. Comparisons with measurements published in Part 1 for the average flow quantities at the exit of both rows are presented. Row patterns close to the rotor tip-clearance region are illustrated.


2013 ◽  
Vol 135 (5) ◽  
Author(s):  
Joshua D. Cameron ◽  
Matthew A. Bennington ◽  
Mark H. Ross ◽  
Scott C. Morris ◽  
Juan Du ◽  
...  

Experimental and numerical studies were conducted to investigate tip-leakage flow and its relationship to stall in a transonic axial compressor. The computational fluid dynamics (CFD) results were used to identify the existence of an interface between the approach flow and the tip-leakage flow. The experiments used a surface-streaking visualization method to identify the time-averaged location of this interface as a line of zero axial shear stress at the casing. The axial position of this line, denoted xzs, moved upstream with decreasing flow coefficient in both the experiments and computations. The line was consistently located at the rotor leading edge plane at the stalling flow coefficient, regardless of inflow boundary condition. These results were successfully modeled using a control volume approach that balanced the reverse axial momentum flux of the tip-leakage flow with the momentum flux of the approach fluid. Nonuniform tip clearance measurements demonstrated that movement of the interface upstream of the rotor leading edge plane leads to the generation of short length scale rotating disturbances. Therefore, stall was interpreted as a critical point in the momentum flux balance of the approach flow and the reverse axial momentum flux of the tip-leakage flow.


Author(s):  
Yu-Tai Lee ◽  
Chunill Hah ◽  
James Loellbach

This paper summarizes a numerical investigation of the fundamental structure of the rotor tip-clearance vortex and its interaction with a passage trailing-edge vortex in a single-stage stator-rotor pump. The flow field of a highly-loaded rotor measured in a high Reynolds number pump facility (HIREP) is used for comparison. The numerical solution was obtained by solving the three-dimensional Reynolds averaged Navier-Stokes equations. The calculated results are visualized in order to understand the details of the tip-vortex structure. The study shows that the tip geometry should be accurately represented to predict the tip-vortex structure correctly.


2008 ◽  
Vol 130 (1) ◽  
Author(s):  
Huu Duc Vo ◽  
Choon S. Tan ◽  
Edward M. Greitzer

A computational study to define the phenomena that lead to the onset of short length-scale (spike) rotating stall disturbances has been carried out. Based on unsteady simulations, we hypothesize there are two conditions necessary for the formation of spike disturbances, both of which are linked to the tip clearance flow. One is that the interface between the tip clearance and oncoming flows becomes parallel to the leading-edge plane. The second is the initiation of backflow, stemming from the fluid in adjacent passages, at the trailing-edge plane. The two criteria also imply a circumferential length scale for spike disturbances. The hypothesis and scenario developed are consistent with numerical simulations and experimental observations of axial compressor stall inception. A comparison of calculations for multiple blades with those for single passages also allows statements to be made about the utility of single passage computations as a descriptor of compressor stall.


Author(s):  
P. C. Ivey ◽  
M. Swoboda

This paper describes work conducted as part of an experimental and numerical study of leakage effects by numerous Research and Industrial partners. For clarity it is presented in two parts. Part 1 presents measurements of tip-clearance flow for a 3rd stage rotor embedded in a four stage low-speed research compressor. The measurements are innovative and comprise measurements in the rotor relative frame of reference and 3D Laser time-of-flight Anemometry. Both techniques are relevant for improved understanding of multistage compressor flow dynamics and consequently, validated multistage CFD simulations. In part 2 of this paper (see Politis et al 1997b) it is shown that downstream of the rotor passage the location and size of a tip-clearance vortex, identified from both independent measurement techniques in Part 1, is in good agreement with 3D solutions of the Navier-Stokes equations modelling this compressor. These 3D numerical solutions reveal the tip-clearance flow structure using a multiblock grid technique.


Sign in / Sign up

Export Citation Format

Share Document