The Impact of Casing Groove Location on Stall Margin and Tip Clearance Flow in a Low-Speed Axial Compressor

2016 ◽  
Vol 138 (12) ◽  
Author(s):  
Du Juan ◽  
Li Jichao ◽  
Gao Lipeng ◽  
Lin Feng ◽  
Chen Jingyi

In this study, the impact of single grooves at different locations on compressor stability and tip clearance flow are numerically and experimentally investigated. Initially, the numerical stall margin improvement (SMI) curve is examined using experimental data. Then, the evolution of the interface between the tip leakage flow (TLF) and the incoming main flow (MF) in the prestall and stall inception processes for two typical grooves, i.e., the worst and the optimal grooves in terms of their SMI, are compared with the smooth casing. The results show two different interface behaviors throughout the throttling process. The compressor with the worst single groove casing first experiences a long-length-scale disturbance after the interface near the blade suction side spills in front of the rotor leading-edge plane, and then goes through spikes after the whole interface spills. With the smooth casing and the optimal single groove near midchord, the interface reaches the rotor leading edge at the last stable operating point and spikes appear once the whole interface spills over the rotor leading edge. A model that illustrates the spillage patterns of the interface for the two stall precursors is thus proposed accordingly and used to explain their effectiveness in terms of the SMI. At last, the relevance of these results to the preliminary selection of groove locations for multigroove casing treatments (CTs) is verified by test data and discussed.

Author(s):  
Matthew A. Bennington ◽  
Mark H. Ross ◽  
Joshua D. Cameron ◽  
Scott C. Morris ◽  
Juan Du ◽  
...  

A numerical and experimental study was conducted to investigate the tip clearance flow and its relationship to stall in a transonic axial compressor. The CFD results were used to identify the existence of an interface between incoming axial flow and the reverse tip clearance flow. A surface streaking method was used to experimentally identify this interface as a line of zero axial shear stress at the casing. The position of this line, denoted xzs, moved upstream with decreasing flow coefficient in both the experiments and computations. The line was found to be at the rotor leading edge plane when the compressor stalled. Further measurements using rotor offset and inlet distortion further corroborated these results, and demonstrated that the movement of the interface upstream of the leading edge leads to the generation of rotating (“spike”) disturbances. Stall was therefore interpreted to occur as a result of a critical momentum balance between the approach fluid and the tip-leakage flow.


Author(s):  
Chunill Hah

Effects of axial casing grooves (ACGs) on the stall margin and efficiency of a one and a half stage low-speed axial compressor with a large rotor tip gap are investigated in detail. The primary focus of the current paper is to identify the flow mechanisms behind the changes in stall margin and on the efficiency of the compressor stage with a large rotor tip gap. Semicircular axial grooves installed in the rotor’s leading edge area are investigated. A large eddy simulation (LES) is applied to calculate the unsteady flow field in a compressor stage with ACGs. The calculated flow fields are first validated with previously reported flow visualizations and stereo PIV (SPIV) measurements. An in-depth examination of the calculated flow field indicates that the primary mechanism of the ACG is the prevention of full tip leakage vortex (TLV) formation when the rotor blade passes under the axial grooves periodically. The TLV is formed when the incoming main flow boundary layer collides with the tip clearance flow boundary layer coming from the opposite direction near the casing and rolls up around the rotor tip vortex. When the rotor passes directly under the axial groove, the tip clearance flow boundary layer on the casing moves into the ACGs and no roll-up of the incoming main flow boundary layer can occur. Consequently, the full TLV is not formed periodically as the rotor passes under the open casing of the axial grooves. Axial grooves prevent the formation of the full TLV. This periodic prevention of the full TLV generation is the main mechanism explaining how the ACGs extend the compressor stall margin by reducing the total blockage near the rotor tip area. Flows coming out from the front of the grooves affect the overall performance as it increases the flow incidence near the leading edge and the blade loading with the current ACGs. The primary flow mechanism of the ACGs is periodic prevention of the full TLV formation. Lower efficiency and reduced pressure rise at higher flow rates for the current casing groove configuration are due to additional mixing between the main passage flow and the flow from the grooves. At higher flow rates, blockage generation due to this additional mixing is larger than any removal of the flow blockage by the grooves. Furthermore, stronger double-leakage tip clearance flow is generated with this additional mixing with the ACGs at a higher flow rate than that of the smooth wall.


2008 ◽  
Vol 130 (1) ◽  
Author(s):  
Huu Duc Vo ◽  
Choon S. Tan ◽  
Edward M. Greitzer

A computational study to define the phenomena that lead to the onset of short length-scale (spike) rotating stall disturbances has been carried out. Based on unsteady simulations, we hypothesize there are two conditions necessary for the formation of spike disturbances, both of which are linked to the tip clearance flow. One is that the interface between the tip clearance and oncoming flows becomes parallel to the leading-edge plane. The second is the initiation of backflow, stemming from the fluid in adjacent passages, at the trailing-edge plane. The two criteria also imply a circumferential length scale for spike disturbances. The hypothesis and scenario developed are consistent with numerical simulations and experimental observations of axial compressor stall inception. A comparison of calculations for multiple blades with those for single passages also allows statements to be made about the utility of single passage computations as a descriptor of compressor stall.


2018 ◽  
Vol 141 (1) ◽  
Author(s):  
Chunill Hah

Effects of axial casing grooves (ACGs) on the stall margin and efficiency of a one and a half stage low-speed axial compressor with a large rotor tip gap are investigated in detail. The primary focus of the current paper is to identify the flow mechanisms behind the changes in stall margin and on the efficiency of the compressor stage with a large rotor tip gap. Semicircular axial grooves installed in the rotor's leading edge area are investigated. A large eddy simulation (LES) is applied to calculate the unsteady flow field in a compressor stage with ACGs. The calculated flow fields are first validated with previously reported flow visualizations and stereo particle image velocimetry (SPIV) measurements. An in-depth examination of the calculated flow field indicates that the primary mechanism of the ACG is the prevention of full tip leakage vortex (TLV) formation when the rotor blade passes under the axial grooves periodically. The TLV is formed when the incoming main flow boundary layer collides with the tip clearance flow boundary layer coming from the opposite direction near the casing and rolls up around the rotor tip vortex. When the rotor passes directly under the axial groove, the tip clearance flow boundary layer on the casing moves into the ACGs and no roll-up of the incoming main flow boundary layer can occur. Consequently, the full TLV is not formed periodically as the rotor passes under the open casing of the axial grooves. Axial grooves prevent the formation of the full TLV. This periodic prevention of the full TLV generation is the main mechanism explaining how the ACGs extend the compressor stall margin by reducing the total blockage near the rotor tip area. Flows coming out from the front of the grooves affect the overall performance as it increases the flow incidence near the leading edge and the blade loading with the current ACGs. The primary flow mechanism of the ACGs is periodic prevention of the full TLV formation. Lower efficiency and reduced pressure rise at higher flow rates for the current casing groove configuration are due to additional mixing between the main passage flow and the flow from the grooves. At higher flow rates, blockage generation due to this additional mixing is larger than any removal of the flow blockage by the grooves. Furthermore, stronger double-leakage tip clearance flow is generated with this additional mixing with the ACGs at a higher flow rate than that of the smooth wall.


Author(s):  
Huu Duc Vo ◽  
Choon S. Tan ◽  
Edward M. Greitzer

A computational study to define the phenomena that lead to the onset of short length-scale (spike) rotating stall disturbances has been carried out. Unsteady simulations show there are two conditions necessary for the formation of spike disturbances, both of which are linked to the tip clearance flow. One is that the interface between the tip clearance and oncoming flows becomes parallel to the leading edge plane. The second is the initiation of backflow, stemming from the fluid in adjacent passages, at the trailing edge plane. The two criteria also imply a length scale circumferential extent of spike disturbances. The scenario developed is consistent with numerical simulations as well as with experimental observations of axial compressor stall inception. A comparison of calculations for multiple blades with those for single passages also allows statements to be made about the utility of single passage computations as a descriptor of compressor stall.


Author(s):  
Hong-Sik Im ◽  
Ge-Cheng Zha

This paper investigates non-synchronous vibration (NSV) mechanism of a high-speed axial compressor with three different rotor tip clearances. Numerical simulations for 1/7th annulus periodic sector are performed using an unsteady Reynolds-averaged Navier-Stokes(URANS) solver with a fully conservative sliding boundary condition to capture wake unsteadiness between the rotor and stator blades. The simulated NSV shows that the frequency and amplitude are strongly influenced by the tip clearance size and shape. The predicted NSV frequency is in good agreement with the experiment. The maximum amplitude of the NSV occurs at about 78% span of the rotor suction leading edge regardless of tip clearance due to a strong interaction of incoming flow, tip leakage flow and tip vortex. The instability of tornado like tip vortex oscillating in streamwise direction appears to be the main cause of the NSV observed in this study.


Author(s):  
N. A. Cumpsty

Results are presented and discussed from an axial compressor rotor operated with an axial skewed slot casing treatment over part of the circumference. The compressor was one for which stall was initiated in the tip region and for this type there is some potential for stall margin improvement with lower loss using this. The main significance of the experiments is, however, the possibility of looking at aspects of stall inception. Normally stall inception is a brief transient with an unknown start time and is difficult to study but with the partial casing treatment it was possible to make the untreated section operate continuously in such a way that it underwent the processes normally leading to stall. For a tip stalling rotor the experiments identify the annulus boundary layer as the crucial region of the flow and spillage of the tip-clearance flow forward of the blades as a process leading to the rapid build up of blockage prior to instability and stall.


Author(s):  
Wei Li ◽  
Wei-Yang Qiao ◽  
Kai-Fu Xu ◽  
Hua-Ling Luo

The tip leakage flow has significant effects on turbine in loss production, aerodynamic efficiency, etc. Then it’s important to minimize these effects for a better performance by adopting corresponding flow control. The active turbine tip clearance flow control with injection from the tip platform is given in Part-1 of this paper. This paper is Part-2 of the two-part papers focusing on the effect of five different passive turbine tip clearance flow control methods on the tip clearance flow physics, which consists of a partial suction side squealer tip (Partial SS Squealer), a double squealer tip (Double Side Squealer), a pressure side tip shelf with inclined squealer tip on a double squealer tip (Improved PS Squealer), a tip platform extension edge in pressure side (PS Extension) and in suction side (SS Extension) respectively. Combined with the turbine rotor and the numerical method mentioned in Part 1, the effects of passive turbine tip clearance flow controls on the tip clearance flow were sequentially simulated. The detailed tip clearance flow fields with different squealer rims were described with the streamline and the velocity vector in various planes parallel to the tip platform or normal to the tip leakage vortex core. Accordingly, the mechanisms of five passive controls were put in evidence; the effects of the passive controls on the turbine efficiency and the tip clearance flow field were highlighted. The results show that the secondary flow loss near the outer casing including the tip leakage flow and the casing boundary layer can be reduced in all the five passive control methods. Comparing the active control with the passive control, the effect brought by the active injection control on the tip leakage flow is evident. The turbine rotor efficiency could be increased via the rational passive turbine tip clearance flow control. The Improved PS Squealer had the best effect on turbine rotor efficiency, and it increased by 0.215%.


Author(s):  
José Ramón Serrano ◽  
Roberto Navarro ◽  
Luis Miguel García-Cuevas ◽  
Lukas Benjamin Inhestern

Tip leakage loss characterization and modeling plays an important role in small size radial turbine research. The momentum of the flow passing through the tip gap is highly related with the tip leakage losses. The ratio of fluid momentum driven by the pressure gradient between suction side and pressure side and the fluid momentum caused by the shroud friction has been widely used to analyze and to compare different sized tip clearances. However, the commonly used number for building this momentum ratio lacks some variables, as the blade tip geometry data and the viscosity of the used fluid. To allow the comparison between different sized turbocharger turbine tip gaps, work has been put into finding a consistent characterization of radial tip clearance flow. Therefore, a non-dimensional number has been derived from the Navier Stokes Equation. This number can be calculated like the original ratio over the chord length. Using the results of wide range CFD data, the novel tip leakage number has been compared with the traditional and widely used ratio. Furthermore, the novel tip leakage number can be separated into three different non-dimensional factors. First, a factor dependent on the radial dimensions of the tip gap has been found. Second, a factor defined by the viscosity, the blade loading, and the tip width has been identified. Finally, a factor that defines the coupling between both flow phenomena. These factors can further be used to filter the tip gap flow, obtained by CFD, with the influence of friction driven and pressure driven momentum flow.


Author(s):  
Wei Zhu ◽  
Songtao Wang ◽  
Longxin Zhang ◽  
Jun Ding ◽  
Zhongqi Wang

This study aimed to enhance the understanding of flow phenomena in low-reaction aspirated compressors. Three-dimensional, multi-passage steady and unsteady numerical simulations are performed to investigate the performance sensitivity to tip clearance variation on the first-stage rotor of a multistage low-reaction aspirated compressor. Three kinds of tip clearance sizes including 1.0τ, 2.0τ and 3.0τ are modeled, in which 1.0τ corresponds to the designed tip clearance size of 0.2 mm. The steady numerical simulations show that the overall performance of the rotor moves toward lower mass flow rate when the tip clearance size is increased. Moreover, energy losses, efficiency reduction and stall margin decrease are also observed with increasing tip clearance size. This can be mostly attributed to the damaging impact of intense tip clearance flow. For unsteady simulation, the result shows periodical oscillation of the tip leakage vortex and a “two-passage periodic structure” in the tip region at the near-stall point. The occurrence of the periodical oscillation is due to the severe interaction between the tip clearance flow and the shock wave. However, the rotor operating state is still stable at this working point because a dynamic balance is established between the tip clearance flow and incoming flow.


Sign in / Sign up

Export Citation Format

Share Document