Multi-Blade Row Interactions in a Low Pressure Ratio Centrifugal Compressor Stage With a Vaned Diffuser

Author(s):  
Kishore Ramakrishnan ◽  
Simon K. Richards ◽  
Franc¸ois Moyroud ◽  
Vittorio Michelassi

Previous experimental and CFD investigation of a GE Oil and Gas centrifugal compressor stage with a vaneless diffuser revealed a complex excitation mechanism caused by an aero-acoustic interaction between three blade rows. In stages with vaned diffusers, additional sources of aeromechanical excitation on the impeller can be expected. This unsteady CFD investigation is a follow-up from the previous vaneless diffuser study to identify any additional sources of excitation that arise in the presence of a vaned diffuser in preparation for aeromechanic tests to be conducted later. The study confirms that excitation from impeller-diffuser interaction generated acoustic modes can dominate the potential field excitation from the diffuser vanes. In addition, a significant aero-acoustic excitation to the impeller at a vane pass frequency corresponding to the sum of the vane counts in the two downstream vane rows is observed, and its origination is discussed. The latter excitation is different from that observed in the vaneless diffuser stage where the vane pass frequency observed by the impeller corresponds to the sum of the vane counts in the upstream and downstream vane rows.

Author(s):  
T. Ch. Siva Reddy ◽  
G. V. Ramana Murty ◽  
Prasad Mukkavilli ◽  
D. N. Reddy

Numerical simulation of impeller and low solidity vaned diffuser (LSD) of a centrifugal compressor stage is performed individually using CFX- BladeGen and BladeGenPlus codes. The tip mach number for the chosen study was 0.35. The same configuration was used for experimental investigation for a comparative study. The LSD vane is formed using standard NACA profile with marginal modification at trailing edge. The performance parameters obtained form numerical studies at the exit of impeller and the diffuser have been compared with the corresponding experimental data. These parameters are pressure ratio, polytropic efficiency and flow angle at the impeller exit where as the parameters those have been compared at the exit of diffuser are the static pressure recovery coefficient and the exit flow angle. In addition, the numerical prediction of the blade loading in terms of blade surface pressure distribution on LSD vane has been compared with the corresponding experimental results. Static pressure recovery coefficient and flow angle at diffuser exit is seen to match closely at higher flows. The difference at lower flows could be due to the effect of interaction between impeller and diffuser combinations, as the numerical analysis was done separately for impeller and diffuser and the effect of impeller diffuser interaction was not considered.


Author(s):  
Chaolei Zhang ◽  
Qinghua Deng ◽  
Zhenping Feng

This paper describes the aerodynamic redesign and optimization of a typical single stage centrifugal compressor, in which the total pressure ratio was improved from the original 4.0 to final 5.0 with the restrictions of keeping the impeller tip diameter, the design rotational speed and the design mass flow rate unchanged. Firstly the backsweep angle and the outlet blade height of the impeller were adjusted and the vaned diffuser was redesigned. Then a sensitivity analysis of the aerodynamic performance correlated to the primary redesign centrifugal compressor stage with respect to the chosen redesign variables was conducted, according to the parameterized results of the impeller and the vaned diffuser. Secondly the impeller and the vaned diffuser were optimized respectively under the stage environment at the design operation condition to improve the stage isentropic efficiency by using a global optimization method which coupled Evolutionary Algorithm (EA) and Artificial Neural Network (ANN), provided by the commercial software NUMECA DESIGN-3D. Subsequently the detailed performance maps of the centrifugal compressor stage corresponding to the primary redesign configuration and the optimum configuration were presented by Computational Fluid Dynamics (CFD) simulation. Finally the flow fields correlated to the centrifugal compressor configurations before and after optimization at the design operation condition were also compared and analyzed in detail. As a result the design target was achieved after the primary redesign, as a 2.7% gain in stage efficiency and a 3.6% increase in stage pressure ratio were obtained when compared with the primary redesign configuration after optimization. Moreover, the aerodynamic performance of the optimum configuration at the off-design operation conditions was also improved.


Author(s):  
James M. Sorokes ◽  
Jason A. Kopko

The paper addresses the use of a rib style (partial height) vaned diffuser to improve the flowfield downstream of a high flow coefficient centrifugal impeller. Empirical and analytical (3-D CFD) results are presented for both the original vaneless diffuser and the replacement rib configuration. Comparisons are made between the CFD results and the data obtained through single stage rig (SSTR) testing. Comments are offered regarding the qualitative and quantitative agreement between the empirical and analytical results.


2009 ◽  
Vol 131 (4) ◽  
Author(s):  
Isabelle Trébinjac ◽  
Pascale Kulisa ◽  
Nicolas Bulot ◽  
Nicolas Rochuon

Numerical and experimental investigations were conducted in a transonic centrifugal compressor stage composed of a backswept splittered unshrouded impeller and a vaned diffuser. The characteristic curves of the compressor stage resulting from the unsteady simulations and the experiments show a good agreement over the whole operating range. On the contrary, the total pressure ratio resulting from the steady simulations is clearly overestimated. A detailed analysis of the flow field at design operating point led to identify the physical mechanisms involved in the blade row interaction that underlie the observed shift in performance. Attention was focused on the deformation in shape of the vane bow shock wave due its interaction with the jet and wake flow structure emerging from the impeller. An analytical model is proposed to quantify the time-averaged effects of the associated entropy increase. The model is based on the calculation of the losses across a shock wave at various inlet Mach numbers corresponding to the moving of the jet and wake flow in front of the shock wave. The model was applied to the compressor stage performance calculated with the steady simulations. The resulting curve of the overall pressure ratio as a function of the mass flow is clearly shifted toward the unsteady results. The model, in particular, enhances the prediction of the choked mass flow.


Author(s):  
Isabelle Tre´binjac ◽  
Pascale Kulisa ◽  
Nicolas Bulot ◽  
Nicolas Rochuon

Numerical and experimental investigations were conducted in a transonic centrifugal compressor stage composed of a backswept splittered unshrouded impeller and a vaned diffuser. The characteristic curves of the compressor stage resulting from the unsteady simulations and the experiments show a good agreement over the whole operating range. On the contrary, the total pressure ratio resulting from the steady simulations is clearly overestimated. A detailed analysis of the flow field at design operating point led to identify the physical mechanisms involved in the blade row interaction that underlie the observed shift in performance. Attention was focused on the deformation in shape of the vane bow shock wave due its interaction with the jet and wake flow structure emerging from the impeller. An analytical model is proposed to quantify the time-averaged effects of the associated entropy increase. The model is based on the calculation of the losses across a shock wave at various inlet Mach numbers corresponding to the moving of the jet and wake flow in front of the shock wave. The model was applied to the compressor stage performance calculated with the steady simulations. The resulting curve of the overall pressure ratio as a function of the mass flow is clearly shifted towards the unsteady results. The model in particular enhances the prediction of the choked mass flow.


2013 ◽  
Vol 30 (2) ◽  
pp. 113-121 ◽  
Author(s):  
L. H. Jawad ◽  
S. Abdullah ◽  
R. Zulkifli ◽  
W. M. F. W. Mahmood

ABSTRACTThis paper is a numerical simulation that was made in the three-dimensional flow, carried out in a modified centrifugal compressor, having vaned diffuser stage, used as an auto-motive turbo charger. Moreover, the performance of the centrifugal compressor was dependent on the proper matching between compressor impeller and vaned diffuser, influencing significantly surge and the efficiency of centrifugal compressor stages. In addition, a modified compressor impeller, coupled with vane and vaneless diffuser, has been found to have similar internal flow patterns for both the vaneless and vaned diffuser design. The vaned diffuser effect has been paid particular attention in terms of better analysis where the diffuser was designed for high sub-sonic inlet conditions. Another aim of this research was to study and simulate the effect of vaned diffuser on the performance of a centrifugal compressor. The simulation was undertaken by using a commercial software, the so-called ANSYS CFX, to predict numerically the performance in terms of pressure ratio, poly tropic efficiency and mass flow rate for the centrifugal compressor stage. The results were generated from CFD and were analyzed for better understanding of the fluid flow through centrifugal compressor stage. Conclusively, it was observed that the effect of the vaned diffuser is to convert the kinetic energy into a high static pressure after analyzing the results of the simulation.


Author(s):  
Cathal Clancy ◽  
François Moyroud ◽  
Kishore Ramakrishnan

Previous experimental and CFD investigation on a GE Oil & Gas centrifugal compressor stage with a vaneless diffuser revealed a complex excitation mechanism caused by aero-acoustic interaction between three blade rows. Recent published studies have indicated that cavities enclosing shrouded impellers may strongly amplify the acoustic excitation of the impeller by Tyler-Sofrin modes. In this current research therefore, the previous CFD study is expanded to include a model of the disk and shroud cavities. A linearized Navier-Stokes frequency sweep in forced response mode shows a well-defined peak in cavity acoustic activity at a certain frequency. It also shows that the inclusion of cavities noticeably increases the modal forcing on the impeller, qualitatively confirming findings in existing literature. A significant difference in modal force magnitude is found between the shroud-disk out-of-phase mode and the in-phase mode, which is consistent with experimental measurements of vibratory response.


2017 ◽  
Vol 140 (1) ◽  
Author(s):  
Lee Galloway ◽  
Stephen Spence ◽  
Sung In Kim ◽  
Daniel Rusch ◽  
Klemens Vogel ◽  
...  

The stable operating range of a centrifugal compressor stage of an engine turbocharger is limited at low mass flow rates by aerodynamic instabilities which can lead to the onset of rotating stall or surge. There have been many techniques employed to increase the stable operating range of centrifugal compressor stages. The literature demonstrates that there are various possibilities for adding special treatments to the nominal diffuser vane geometry, or including injection or bleed flows to modify the diffuser flow field in order to influence diffuser stability. One such treatment is the porous throat diffuser (PTD). Although the benefits of this technique have been proven in the existing literature, a comprehensive understanding of how this technique operates is not yet available. This paper uses experimental measurements from a high pressure ratio (PR) compressor stage to acquire a sound understanding of the flow features within the vaned diffuser which affect the stability of the overall compression system and investigate the stabilizing mechanism of the porous throat diffuser. The nonuniform circumferential pressure imposed by the asymmetric volute is experimentally and numerically examined to understand if this provides a preferential location for stall inception in the diffuser. The following hypothesis is confirmed: linking of the diffuser throats via the side cavity equalizes the diffuser throat pressure, thus creating a more homogeneous circumferential pressure distribution, which delays stall inception to lower flow rates. The results of the porous throat diffuser configuration are compared to a standard vaned diffuser compressor stage in terms of overall compressor performance parameters, circumferential pressure nonuniformity at various locations through the compressor stage and diffuser subcomponent analysis. The diffuser inlet region was found to be the element most influenced by the porous throat diffuser, and the stability limit is mainly governed by this element.