Simplified Simulation Block Diagram of Twin-Shaft Gas Turbines

Author(s):  
Luca Bozzi ◽  
Giampaolo Crosa ◽  
Angela Trucco

This paper provides a simplified mathematical model of twin shaft gas turbine suitable for use in dynamic studies of both electric power generation plants and variable speed mechanical drive applications. The main purpose was to define a simulation block diagram, constituted by algebraic equations and simplified transfer functions, which can be easily derived from the gas plant design data utilising the suitable equations and nomographs presented in the paper. The 3 to 30 MW power range of twin shaft gas turbines is covered. The set-up parameters and details applicable to the model are listed, in the paper, for the various machine sizes and model series. The dynamic model has been developed by simplifying a more detailed one, also here presented, with relatively little loss in dynamic accuracy but considerable advantages in terms of computational time. In the proposed test case, the results of both models have been compared simulating the transient response of a twin shaft gas turbine powering a water-jet propulsor for high-speed ships. The accurate performance prediction capability of both models is verified, for a wide range of operating conditions, by comparison with test results from actual field installations.

Author(s):  
Dominik Ebi ◽  
Peter Jansohn

Abstract Operating stationary gas turbines on hydrogen-rich fuels offers a pathway to significantly reduce greenhouse gas emissions in the power generation sector. A key challenge in the design of lean-premixed burners, which are flexible in terms of the amount of hydrogen in the fuel across a wide range and still adhere to the required emissions levels, is to prevent flame flashback. However, systematic investigations on flashback at gas turbine relevant conditions to support combustor development are sparse. The current work addresses the need for an improved understanding with an experimental study on boundary layer flashback in a generic swirl burner up to 7.5 bar and 300° C preheat temperature. Methane-hydrogen-air flames with 50 to 85% hydrogen by volume were investigated. High-speed imaging was applied to reveal the flame propagation pathway during flashback events. Flashback limits are reported in terms of the equivalence ratio for a given pressure, preheat temperature, bulk flow velocity and hydrogen content. The wall temperature of the center body along which the flame propagated during flashback events has been controlled by an oil heating/cooling system. This way, the effect any of the control parameters, e.g. pressure, had on the flashback limit was de-coupled from the otherwise inherently associated change in heat load on the wall and thus change in wall temperature. The results show that the preheat temperature has a weaker effect on the flashback propensity than expected. Increasing the pressure from atmospheric conditions to 2.5 bar strongly increases the flashback risk, but hardly affects the flashback limit beyond 2.5 bar.


Author(s):  
R. Friso ◽  
N. Casari ◽  
M. Pinelli ◽  
A. Suman ◽  
F. Montomoli

Abstract Gas turbines (GT) are often forced to operate in harsh environmental conditions. Therefore, the presence of particles in their flow-path is expected. With this regard, deposition is a problem that severely affects gas turbine operation. Components’ lifetime and performance can dramatically vary as a consequence of this phenomenon. Unfortunately, the operating conditions of the machine can vary in a wide range, and they cannot be treated as deterministic. Their stochastic variations greatly affect the forecasting of life and performance of the components. In this work, the main parameters considered affected by the uncertainty are the circumferential hot core location and the turbulence level at the inlet of the domain. A stochastic analysis is used to predict the degradation of a high-pressure-turbine (HPT) nozzle due to particulate ingestion. The GT’s component analyzed as a reference is the HPT nozzle of the Energy-Efficient Engine (E3). The uncertainty quantification technique used is the probabilistic collocation method (PCM). This work shows the impact of the operating conditions uncertainties on the performance and lifetime reduction due to deposition. Sobol indices are used to identify the most important parameter and its contribution to life. The present analysis enables to build confidence intervals on the deposit profile and on the residual creep-life of the vane.


2021 ◽  
Author(s):  
Austin Matthews ◽  
Anna Cobb ◽  
Subodh Adhikari ◽  
David Wu ◽  
Tim Lieuwen ◽  
...  

Abstract Understanding thermoacoustic instabilities is essential for the reliable operation of gas turbine engines. To complicate this understanding, the extreme sensitivity of gas turbine combustors can lead to instability characteristics that differ across a fleet. The capability to monitor flame transfer functions in fielded engines would provide valuable data to improve this understanding and aid in gas turbine operability from R&D to field tuning. This paper presents a new experimental facility used to analyze performance of full-scale gas turbine fuel injector hardware at elevated pressure and temperature. It features a liquid cooled, fiber-coupled probe that provides direct optical access to the heat release zone for high-speed chemiluminescence measurements. The probe was designed with fielded applications in mind. In addition, the combustion chamber includes an acoustic sensor array and a large objective window for verification of the probe using high-speed chemiluminescence imaging. This work experimentally demonstrates the new setup under scaled engine conditions, with a focus on operational zones that yield interesting acoustic tones. Results include a demonstration of the probe, preliminary analysis of acoustic and high speed chemiluminescence data, and high speed chemiluminescence imaging. The novelty of this paper is the deployment of a new test platform that incorporates full-scale engine hardware and provides the ability to directly compare acoustic and heat release response in a high-temperature, high-pressure environment to determine the flame transfer functions. This work is a stepping-stone towards the development of an on-line flame transfer function measurement technique for production engines in the field.


Author(s):  
Marek Dzida ◽  
Krzysztof Kosowski

In bibliography we can find many methods of determining pressure drop in the combustion chambers of gas turbines, but there is only very few data of experimental results. This article presents the experimental investigations of pressure drop in the combustion chamber over a wide range of part-load performances (from minimal power up to take-off power). Our research was carried out on an aircraft gas turbine of small output. The experimental results have proved that relative pressure drop changes with respect to fuel flow over the whole range of operating conditions. The results were then compared with theoretical methods.


Author(s):  
M. S. N. Murthy ◽  
Subhash Kumar ◽  
Sheshadri Sreedhara

Abstract A gas turbine engine (GT) is very complex to design and manufacture considering the power density it offers. Development of a GT is also iterative, expensive and involves a long lead time. The components of a GT, viz compressor, combustor and turbine are strongly dependent on each other for the overall performance characteristics of the GT. The range of compressor operation is dependent on the functional and safe limits of surging and choking. The turbine operating speeds are required to be matched with that of compressor for wide range of operating conditions. Due to this constrain, design for optimum possible performance is often sacrificed. Further, once catered for a design point, gas turbines offer low part load efficiencies at conditions away from design point. As a more efficient option, a GT is practically achievable in a split configuration, where the compressor and turbine rotate on different shafts independently. The compressor is driven by a variable speed electric motor. The power developed in the combustor using the compressed air from the compressor and fuel, drives the turbine. The turbine provides mechanical shaft power through a gear box if required. A drive taken from the shaft rotates an electricity generator, which provides power for the compressor’s variable speed electric motor through a power bank. Despite introducing, two additional power conversions compared to a conventional GT, this split configuration named as ‘Part Electric Gas Turbine’, has a potential for new applications and to achieve overall better efficiencies from a GT considering the poor part load characteristics of a conventional GT.


Author(s):  
Riccardo Da Soghe ◽  
Bruno Facchini ◽  
Luca Innocenti ◽  
Mirko Micio

Reliable design of secondary air system is one of the main tasks for the safety, unfailing and performance of gas turbine engines. To meet the increasing demands of gas turbines design, improved tools in prediction of the secondary air system behavior over a wide range of operating conditions are needed. A real gas turbine secondary air system includes several components, therefore its analysis is not carried out through a complete CFD approach. Usually, that predictions are performed using codes, based on simplified approach which allows to evaluate the flow characteristics in each branch of the air system requiring very poor computational resources and few calculation time. Generally the available simplified commercial packages allow to correctly solve only some of the components of a real air system and often the elements with a more complex flow structure cannot be studied; among such elements, the analysis of rotating cavities is very hard. This paper deals with a design-tool developed at the University of Florence for the simulation of rotating cavities. This simplified in-house code solves the governing equations for steady one-dimensional axysimmetric flow using experimental correlations both to incorporate flow phenomena caused by multidimensional effects, like heat transfer and flow field losses, and to evaluate the circumferential component of velocity. Although this calculation approach does not enable a correct modeling of the turbulent flow within a wheel space cavity, the authors tried to create an accurate model taking into account the effects of inner and outer flow extraction, rotor and stator drag, leakages, injection momentum and, finally, the shroud/rim seal effects on cavity ingestion. The simplified calculation tool was designed to simulate the flow in a rotating cavity with radial outflow both with a Batchelor and/or Stewartson flow structures. A primary 1D-code testing campaign is available in the literature [1]. In the present paper the authors develop, using CFD tools, reliable correlations for both stator and rotor friction coefficients and provide a full 1D-code validation comparing, due to lack of experimental data, the in house design-code predictions with those evaluated by CFD.


Author(s):  
J. Zelina ◽  
D. T. Shouse ◽  
J. S. Stutrud ◽  
G. J. Sturgess ◽  
W. M. Roquemore

An aero gas turbine engine has been proposed that uses a near-constant-temperature (NCT) cycle and an Inter-Turbine Burner (ITB) to provide large amounts of power extraction from the low-pressure turbine. This level of energy is achieved with a modest temperature rise across the ITB. The additional energy can be used to power a large geared fan for an ultra-high bypass ratio transport aircraft, or to drive an alternator for large amounts of electrical power extraction. Conventional gas turbines engines cannot drive ultra-large diameter fans without causing excessively high turbine temperatures, and cannot meet high power extraction demands without a loss of engine thrust. Reducing the size of the combustion system is key to make use of a NCT gas turbine cycle. Ultra-compact combustor (UCC) concepts are being explored experimentally. These systems use high swirl in a circumferential cavity about the engine centerline to enhance reaction rates via high cavity g-loading on the order of 3000 g’s. Any increase in reaction rate can be exploited to reduce combustor volume. The UCC design integrates compressor and turbine features which will enable a shorter and potentially less complex gas turbine engine. This paper will present experimental data of the Ultra-Compact Combustor (UCC) performance in vitiated flow. Vitiation levels were varied from 12–20% oxygen levels to simulate exhaust from the high pressure turbine (HPT). Experimental results from the ITB at atmospheric pressure indicate that the combustion system operates at 97–99% combustion efficiency over a wide range of operating conditions burning JP-8 +100 fuel. Flame lengths were extremely short, at about 50% of those seen in conventional systems. A wide range of operation is possible with lean blowout fuel-air ratio limits at 25–50% below the value of current systems. These results are significant because the ITB only requires a small (300°F) temperature rise for optimal power extraction, leading to operation of the ITB at near-lean-blowout limits of conventional combustor designs. This data lays the foundation for the design space required for future engine designs.


1982 ◽  
Vol 104 (2) ◽  
pp. 429-438 ◽  
Author(s):  
M. B. Cutrone ◽  
M. B. Hilt ◽  
A. Goyal ◽  
E. E. Ekstedt ◽  
J. Notardonato

The work described in this paper is part of the DOE/LeRC Advanced Conversion-Technology Project (ACT). The program is a multiple contract effort with funding provided by the Department of Energy, and technical program management provided by NASA LeRC. Combustion tests are in progress to evaluate the potential of seven advanced combustor concepts for achieving low NOx emissions for utility gas turbine engines without the use of water injection. Emphasis was on the development of the required combustor aerothermodynamic features for burning high nitrogen fuels. Testing was conducted over a wide range of operating conditions for a 12:1 pressure ratio heavy-duty gas turbine. Combustors were evaluated with distillate fuel, SRC-II coal-derived fuel, residual fuel, and blends. Test results indicate that low levels of NOx and fuel-bound nitrogen conversion can be achieved with rich-lean combustors for fuels with high fuel-bound nitrogen. In addition, ultra-low levels of NOx can be achieved with lean-lean combustors for fuels with low fuel-bound nitrogen.


Author(s):  
Stefan Bauer ◽  
Balbina Hampel ◽  
Thomas Sattelmayer

Abstract Vortex generators are known to be effective in augmenting the mixing of fuel jets with air. The configuration investigated in this study is a tubular air passage with fuel injection from one single orifice placed in the side wall. In the range of typical gas turbine combustor inlet temperatures, the performance vortex generator premixers (VGPs) have already been investigated for natural gas as well as for blends of natural gas and hydrogen. However, for highly reactive fuels, the application of VGPs in recuperated gas turbines is particularly challenging because the high combustor inlet temperature leads to potential risk with regard to premature self-ignition and flame flashback. As the current knowledge does not cover the temperature range far above the self-ignition temperature, an experimental investigation of the operational limits of VGPs is currently being conducted at the Thermodynamics Institute of the Technical University of Munich, Garching, Germany, which is particularly focused on reactive fuels and the thermodynamic conditions present in recuperated gas turbines with pressure ratios of 4–5. For the study presented in this paper, an atmospheric combustion VGP test rig has been designed, which facilitates investigations in a wide range of operating conditions in order to comply with the situation in recuperated microgas turbines (MGT), namely, global equivalence ratios between 0.2 and 0.7, air preheating temperatures between 288 K and 1100 K, and air bulk flow rates between 6 and 16 g/s. Both the entire mixing zone in the VGP and the primary combustion zone of the test rig are optically accessible. High-speed OH* chemiluminescence imaging is used for the detection of the flashback and blow-off limits of the investigated VGPs. Flashback and blow-off limits of hydrogen in a wide temperature range covering the autoignition regime are presented, addressing the influences of equivalence ratio, air preheating temperature, and momentum ratio between air and hydrogen on the operational limits in terms of bulk flow velocity. It is shown that flashback and blow-off limits are increasingly influenced by autoignition in the ultrahigh temperature regime.


Author(s):  
Stefan Bauer ◽  
Balbina Hampel ◽  
Thomas Sattelmayer

Vortex generators are known to be effective in augmenting the mixing of fuel jets with air. The configuration investgated in this study is a tubular air passage with fuel injection from one single orifice placed in the side wall. In the range of typical gas turbine combustor inlet temperatures, the performance vortex generator premixers (VGPs) have already been investigated for natural gas as well as for blends of natural gas and hydrogen. However, for highly reactive fuels, the application of VGPs in recuperated gas turbines is particularly challenging because the high combustor inlet temperature leads to potential risk with regard to premature self-ignition and flame flashback. As the current knowledge does not cover the temperature range far above the self-ignition temperature, an experimental investigation of the operational limits of VGPs is currently being conducted at the Thermodynamics Institute of the Technical University of Munich, which is particularly focused on reactive fuels and the thermodynamic conditions present in recuperated gas turbines with pressure ratios of 4–5. For the study presented in the paper, an atmospheric combustion VGP test rig has been designed, which facilitates investigations in a wide range of operating conditions in order to comply with the situation in recuperated micro gas turbines, namely global equivalence ratios between 0.2 and 0.7, air preheating temperatures between 288K and 1100K, and air bulk flow rates between 6–16 g/s. Both the entire mixing zone in the VGP and the primary combustion zone of the test rig are optically accessible. High speed OH* chemiluminescence imaging is used for the detection of the flashback and blow-off limits of the investigated VGPs. Flashback and blow-off limits of hydrogen in a wide temperature range covering the auto-ignition regime are presented, addressing the influences of equivalence ratio, air preheating temperature and momentum ratio between air and hydrogen on the operational limits in terms of bulk flow velocity. It is shown that flashback and blow-off limits are increasingly influenced by auto-ignition in the ultra-high temperature regime.


Sign in / Sign up

Export Citation Format

Share Document