scholarly journals Three-Dimensional Simulation of Wind-Driven Ventilation Through a Windcatcher With Different Inlet Designs

Author(s):  
Peter Abdo ◽  
Rahil Taghipour ◽  
B. Phuoc Huynh

Abstract Windcatcher is an effective natural ventilation system, and its performance depends on several factors including wind speed and wind direction. It provides a comfortable and healthy indoor environment since the introduced fresh air decreases the moisture content and reduces the pollutant concentration. Since the wind speed and its direction are generally unpredictable, it is important to use special inlet forms and exits to increase the efficiency of a windcatcher. In this study, computational fluid dynamics (CFD) modeling is implemented using ansys fluent to investigate the airflow entering a three-dimensional room through a windcatcher with different inlet designs. Three designs are studied which are a uniform inlet, a divergent inlet, and a bulging-convergent inlet. The airflow pattern with all inlets provided adequate ventilation through the room. With all the applied wind velocities (1, 2, 3, and 6 m/s) at the domain's inlet, the divergent inlet shape has captured the highest airflow through the room and provided higher average velocity at 1.2 m high enhancing the thermal comfort where most of the human occupancy occurs. With 6 m/s wind velocity, the divergent inlet has captured 2.55% more flow rate compared to the uniform inlet and 4.70% compared to the bulging-convergent inlet, and it has also provided an average velocity at 1.2 m high in the room of 7.16% higher than the uniform inlet and 8.44% higher than the bulging-convergent inlet.

Author(s):  
Peter Abdo ◽  
Rahil Taghipour ◽  
B. P. Huynh

Abstract Windcatcher has been used over centuries for providing natural ventilation using wind power, it is an effective passive method to provide healthy and comfortable indoor environment. The windcatcher’s function is based on the wind and on the stack effect resulting from temperature differences. Generally, it is difficult for wind to change its direction, and enter a room through usual openings, the windcatcher is designed to overcome such problems since they have vertical columns to help channel wind down to the inside of a building. The efficiency of a windcatcher is maximized by applying special forms of opening and exit. The openings depend on the windcatcher’s location and on its cross sectional area and shape such as square, rectangular, hexagonal or circular. In this study the effect of the inlet design is investigated to achieve better air flow and increase the efficiency of windcatchers. To achieve this, CFD (computational fluid dynamics) tool is used to simulate the air flow in a three dimensional room fitted with a windcatcher based on the different inlet designs. The divergent inlet has captured the highest air flow with a difference of approximately 3% compared to the uniform inlet and 5% difference compared to the bulging-convergent inlet.


2018 ◽  
Vol 2018 ◽  
pp. 1-5
Author(s):  
Ming Li ◽  
Chao Wu ◽  
Zhi-yong Zhou ◽  
Wei-chun Lian ◽  
Zhi-xiong Chen

A set of dust collectors was designed with corrugated plate for an underground metal mine, which has low ventilation resistance, simple maintenance, and strong environmental adaptability. A three-dimensional simulation model was built based on ANSYS-Fluent software, and it was used to analyze the influence law of key parameters on the comprehensive dust removal efficiency; the angle of corrugated plate to the horizontal plane, the surface characteristics of plate, pressure loss and dust removal efficiency were discussed. The optimal design scheme of the dust collector was determined according to the simulation results. The dust collection was carried out in the Fankou lead-zinc underground metal mine in China, and the total dust removal efficiency was more than 95%, and for respiratory dust, it was more than 85%. This dust collector can be widely used in similar underground metal mines.


2018 ◽  
Vol 38 (3) ◽  
pp. 321-327
Author(s):  
Jingfu Jia ◽  
Manjin Hao ◽  
Jianhua Zhao

Forced or natural ventilation is the most common measure of frost heave protection for refrigerated warehouse floor. To optimize air velocity for the underfloor forced ventilation system of refrigerated warehouse, a steady state three-dimensional mathematical model of heat transfer is set up in this paper. The temperature fields of this system are simulated and calculated by CFD software PHOENICS under different air velocity, 1.5m/s, 2.5m/s or 3.5m/s. The results show that the optimized air velocity is 1.5m/s when the tube spacing is 1.5m.


Author(s):  
Peter Abdo ◽  
Rahil Taghipour ◽  
B. P. Huynh

Abstract Natural ventilation is the process of supplying and removing air through an indoor space by natural means. There are two types of natural ventilation occurring in buildings: winddriven ventilation and buoyancy driven or stack ventilation. The most efficient design for natural ventilation in buildings should implement both types of natural ventilation. Stack ventilation which is temperature induced is driven by buoyancy making it less dependent on wind and its direction. Heat emitted causes a temperature difference between two adjoining volumes of air, the warmer air will have lower density and be more buoyant thus will rise above the cold air creating an upward air stream. Combining the wind driven and the buoyancy driven ventilation will be investigated in this study through the use of a windcatcher natural ventilation system. Stack driven air rises as it leaves the windcatcher and it is replaced with fresh air from outside as it enters through the positively pressured windward side. To achieve this, CFD (computational fluid dynamics) tool is used to simulate the air flow in a three dimensional room fitted with a windcatcher based on the winddriven ventilation alone, buoyancy driven ventilation alone, and combined buoyancy and winddriven ventilation. Different wind speeds between 0 up to 2.5 m/s are applied and the total air flow rate through the windcatcher is investigated with and without temperature of 350 K applied at the windcatcher’s outlet wall. As the wind speed increased the efficiency of the solar windcatcher decreased.


SIMULATION ◽  
2019 ◽  
Vol 95 (12) ◽  
pp. 1229-1238 ◽  
Author(s):  
Yunhao Li ◽  
Juncheng Jiang ◽  
Yuan Yu ◽  
Qingwu Zhang

A three-dimensional computational fluid dynamics simulation model resolved by the unsteady Reynolds-Averaged Navier–Stokes equations was developed to predict hydrogen dispersion in an indoor environment. The effect of the height of the crossbeam (Hc) on hydrogen dispersion and distribution behaviors in a four-car garage was numerically investigated under fully confined and natural ventilation conditions. For the fully confined condition, the garage was almost completely filled with a flammable hydrogen cloud at t=600 s. In addition, the volumetric ratio of the flammable region, thickness of the hydrogen stratification, and hydrogen mole fraction all increased as Hc increased. When two symmetric ventilation openings were set up, the volumetric ratio of the flammable region decreased by 50% at t=600 s. Moreover, Hc had evident influence on the vertical distribution of hydrogen mole fraction. In addition, there existed little explosion hazard under the height of 1.6 m. The results show that Hc was a non-negligible factor for the safety design of hydrogen in the garage and Hc=0.12 m was the optimal height of the crossbeam. Furthermore, the ventilation system in the present study cannot completely eliminate the risk of hydrogen explosion. The present risk assessment results can be useful to analyze safety issues in automotive applications of hydrogen.


2018 ◽  
Vol 49 ◽  
pp. 00025 ◽  
Author(s):  
Tomasz Gaczoł

In the following article the author proposes the solution for a properly functioning natural ventilation system based on the use of supply and exhaust ducts, i.e. by designing a natural balanced ventilation system. The paper is devoted to test results of air flow through natural ventilation supply-exhaust ducts in the rooms located on the lower floor of the building. The simulations conducted in ANSYS Fluent software relate to such issues as: pressure system inside the room and in the exhaust duct, distribution of air temperatures in the room, vector direction of airflow through supplyexhaust ducts and in the analysed room. Three types of solutions were selected for the tests: air inflow into the room through the air intake located at the basement level, air inflow through the window ventilator (although no longer used, this solution can be found in many existing residential buildings) and the natural ventilation system supported with the so-called “solar chimney”. All simulations were conducted with an outdoor temperature of +3 degrees C. The indoor temperature is + 20 degrees C, considered to be the minimum thermal comfort level. In the era of common building sealing, the presented ventilation system may be a good solution that guarantees proper functioning of natural ventilation. In all cases presented, it meets the normative regulations and requirements for the ventilation air stream and the air exchange rate in the room. The paper (first part) describes test results concerning the room located on the lower floor of the building, i.e. with a short supply duct and a 12-meter long exhaust duct.


Author(s):  
О. Симбирев ◽  
O. Simbirev

The main problem highlighted in the article is the deviation of the microclimate parameters from the standard values due to the improper organization of airflow in the residential rooms of apartment buildings. The objective is to obtain a working mathematical model of the natural ventilation system, its study for optimization or modernization. The analysis of the normative literature, scientific works of domestic and foreign scientists, developments in the field of natural ventilation and ventilation of residential buildings is carried out. A mathematical model of air exchange of a residential room with convection is presented and analyzed. The flow rate and air temperature, the temperature on the surface of the heater are set as boundary conditions when creating a mathematical model. The features and regularities of airflow distribution in the room obtained as a result of mathematical modeling are revealed. The distributions of air velocity in the room are given. Difficulties of the organization of effective natural inflow of air and the problems with design of valves of infiltration are designated. Technical solutions aimed at improving the quality of indoor microclimate and energy saving are proposed.


Catalysts ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 606
Author(s):  
Valeria Di Sarli ◽  
Marco Trofa ◽  
Almerinda Di Benedetto

A three-dimensional CFD model of a novel configuration of catalytic micro-combustor inspired by the nasal geometry of reindeer was developed using the commercial code ANSYS Fluent 19.0. The thermal behavior of this nature-inspired (NI) configuration was investigated through simulations of lean propane/air combustion performed at different values of residence time (i.e., inlet gas velocity) and (external convective) heat transfer coefficient. Simulations at the same conditions were also run for a standard parallel-channel (PC) configuration of equivalent dimensions. Numerical results show that the operating window of stable combustion is wider in the case of the NI configuration. In particular, the blow-out behavior is substantially the same for the two configurations. Conversely, the extinction behavior, which is dominated by competition between the heat losses towards the external environment and the heat produced by combustion, differs. The NI configuration exhibits a greater ability than the PC configuration to keep the heat generated by combustion trapped inside the micro-reactor. As a consequence, extinction occurs at higher values of residence time and heat transfer coefficient for this novel configuration.


Atmosphere ◽  
2021 ◽  
Vol 12 (10) ◽  
pp. 1284
Author(s):  
Zhao-Yu Chen ◽  
Yen-Hsyang Chu ◽  
Ching-Lun Su

Concurrent measurements of three-dimensional wind velocities made with three co-located wind profilers operated at frequencies of 52 MHz, 449 MHz, and 1.29 GHz for the period 12–16 September 2017 are compared for the first time in this study. The velocity–azimuth display (VAD) method is employed to estimate the wind velocities. The result shows that, in the absence of precipitation, the root mean square difference (RMSD) in the horizontal wind speed velocities U and wind directions D between different pairs of wind profilers are, respectively, in the range of 0.94–0.99 ms−1 and 7.7–8.3°, and those of zonal wind component u and meridional wind component v are in the respective ranges of 0.91–1.02 ms−1 and 1.1–1.24 ms−1. However, the RMSDs between wind profilers and rawinsonde are in the range of 2.89–3.26 ms−1 for horizontal wind speed velocity and 11.17–14.48° for the wind direction, which are around 2–3 factors greater than those between the wind profilers on average. In addition to the RMSDs, MDs between wind profilers and radiosonde are around one order of magnitude larger than those between wind profilers. These results show that the RMSDs, MDs, and Stdds between radars are highly consistent with each other, and they are much smaller than those between radar and rawinsonde. This therefore suggests that the wind profiler-measured horizontal wind velocities are much more reliable, precise, and accurate than the rawinsonde measurement.


Author(s):  
Luis D Mendoza ◽  
Luis E Vera ◽  
Luis E Vera

  Se realizó un análisis computacional, mediante la técnica del CFD, del perfil NACA 2415, con los modelos de turbulencia Realizable K-ε y el modelo de turbulencia K-ω SST para obtener sus curvas aerodinámicas. El software utilizado fue el ANSYS FLUENT V14. La simulación se realizó con mallas no estructuradas y bidimensionales, en un dominio computacional cuyas dimensiones corresponden al túnel de viento AF6109 de la Universidad Nacional Experimental del Táchira, Venezuela. Las curvas aerodinámicas se realizaron para diferentes ángulos de ataque, los cuales consistieron en 0°, 4°, 8°, 12° y 16° respectivamente. Las condiciones de borde usadas están basadas en el túnel de viento AF6109.  La simulación computacional se validó con las curvas aerodinámicas obtenidas mediante el diseño experimental realizado en el túnel de viento. Se concluye que el modelo de turbulencia K-ω SST predice mejor los gradientes adversos de presión. Palabras clave Dinámica de fluidos computacional (CFD), perfiles aerodinámicos


Sign in / Sign up

Export Citation Format

Share Document