Evaluation of Two-Phase Frictional Pressure Drop Correlations Against Experimental Data

Author(s):  
Wei Li ◽  
Kunrong Shen ◽  
Boren Zheng ◽  
Xiang Ma ◽  
S. A. Sherif ◽  
...  

Abstract Results are presented here from an experimental investigation on tube side two-phase characteristics that took place in four tested tubes—the 1EHT-1, 1EHT-2, 4LB, and smooth tubes. The equivalent outer diameter of the tube was 9.52 mm and the inner diameter was 8.32 mm. Condensation tests were conducted using refrigerant R410A at a saturation temperature of 318 K, over a mass flow range of 150–450 kg m−2 s−1, with inlet and outlet vapor qualities of 0.8 and 0.2, respectively. Evaporation tests were performed at a saturation temperature of 279 K, over a mass flow range of 150–380 kg m−2 s−1, with inlet and outlet vapor qualities of 0.2 and 0.8, respectively. Pressure drop data of the four tested tubes were collected to evaluate five identified prediction correlations based on the separated flow model and the homogeneous flow model. The separated flow approaches presented predictions with average MAEs of 24.9% and 16.4% for condensation and evaporation data, respectively, while the average MAEs of the homogeneous flow model were 31.6% and 43.4%, respectively. Almost all the identified correlations underestimated the frictional pressure drop of the 4LB tube with MAEs exceeding 30%. An earlier transition of different flow patterns was expected to occur in the EHT tubes while developing a new diabatic flow pattern map is needed for the 4LB tube. A new correlation was presented based on the two-phase multiplier Φ and the Martinelli parameter Xtt, which exhibited excellent predictive results for the experimental data.

Author(s):  
Kunrong Shen ◽  
Zhichuan Sun ◽  
Wei Li ◽  
Xiang Ma ◽  
Yan He ◽  
...  

Abstract Results are presented here from an experimental investigation on tube side condensation characteristics that took place in four tested tubes — 1EHT-1, 1EHT-2, 4LB and a smooth tube. The equivalent outer diameter of the tubes was 9.52 mm and the inner diameter was 8.32 mm. Condensation tests were conducted using refrigerant R410A at a saturation temperature of 318K, over a mass flow range of 150–450 kgm−2s−1, with inlet and outlet vapor quality of 0.8 and 0.2, respectively. Pressure drop data of the four tested tubes were collected to evaluate five identified prediction correlations based on the separated flow model and the homogeneous flow model. For 1EHT-2 and the smooth tube, all the listed correlations manage to present predictions with the Mean Absolute Relative Deviation (MARD) less than 30%, while they underestimate the frictional pressure drop of the 4LB tube with MARD exceeding 40% averagely. Regarding the experimental data, it is found that the Muller-Steinhagen and Heck correlation presents the most accurate and stable prediction for the 4 tested tubes. The listed homogeneous flow correlations can provide acceptable predictions with MARD ranging from 25% to 40% under a few conditions, but their average predictive accuracies are inferior to that of the separated flow correlations. Consequently, the separated flow approach performs better than the homogeneous flow model in the prediction of frictional pressure drop for our experimental data.


Micromachines ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 510
Author(s):  
Yan Huang ◽  
Bifen Shu ◽  
Shengnan Zhou ◽  
Qi Shi

In this paper, two-phase pressure drop data were obtained for boiling in horizontal rectangular microchannels with a hydraulic diameter of 0.55 mm for R-134a over mass velocities from 790 to 1122, heat fluxes from 0 to 31.08 kW/m2 and vapor qualities from 0 to 0.25. The experimental results show that the Chisholm parameter in the separated flow model relies heavily on the vapor quality, especially in the low vapor quality region (from 0 to 0.1), where the two-phase flow pattern is mainly bubbly and slug flow. Then, the measured pressure drop data are compared with those from six separated flow models. Based on the comparison result, the superficial gas flux is introduced in this paper to consider the comprehensive influence of mass velocity and vapor quality on two-phase flow pressure drop, and a new equation for the Chisholm parameter in the separated flow model is proposed as a function of the superficial gas flux . The mean absolute error (MAE ) of the new flow correlation is 16.82%, which is significantly lower than the other correlations. Moreover, the applicability of the new expression has been verified by the experimental data in other literatures.


2004 ◽  
Vol 126 (4) ◽  
pp. 546-552 ◽  
Author(s):  
Peter M.-Y. Chung ◽  
Masahiro Kawaji ◽  
Akimaro Kawahara ◽  
Yuichi Shibata

An adiabatic experiment was conducted to investigate the effect of channel geometry on gas-liquid two-phase flow characteristics in horizontal microchannels. A water-nitrogen gas mixture was pumped through a 96 μm square microchannel and the resulting flow pattern, void fraction and frictional pressure drop data were compared with those previously reported by the authors for a 100 μm circular microchannel. The pressure drop data were best estimated using a separated-flow model and the void fraction increased non-linearly with volumetric quality, regardless of the channel shape. However, the flow maps exhibited transition boundaries that were shifted depending on the channel shape.


Author(s):  
I˙smail Teke ◽  
O¨zden Ag˘ra ◽  
Hakan Demir ◽  
S¸. O¨zgu¨r Atayılmaz

In this study, the several well known two-phase viscosity models were used for predicting two-phase flow pressure drop in a smooth tube using Computational Fluid Dynamics (CFD) software at homogenous flow conditions. Pressure drop for two different mass flux values (300 and 650 kg/m2s) for R134a with a saturation temperature of 45 °C in a smooth tube has been modeled according to the homogenous flow model and the results have been compared with the analytical formulas and experimental data from the literature. Three different average viscosity correlations were used. It is seen that the numerical results are in a good agreement with the homogenous flow model and fall in ± 30% band. Also, the results derived from the average viscosity expression are in a good agreement with the results calculated using separated two-phase flow correlations. In addition to this, Artificial Neural Networks (ANNs) were employed for predicting the pressure drop in a horizontal smooth pipe. The trained network gives the best values over the correlations with less than 1% mean relative error.


1961 ◽  
Vol 83 (4) ◽  
pp. 613-618 ◽  
Author(s):  
E. S. Kordyban

The paper presents a construction of a simplified model approximating the actual observed flow pattern. The resulting expressions for frictional pressure drop are found to agree fairly well with the author’s data for steam and water and the data for air and water of other investigators. The similarity with a portion of the Chenoweth-Martin correlation appears to present a logical explanation for the applicability of that correlation to slug flow.


Author(s):  
Chaoxing Yan ◽  
Changqi Yan ◽  
Licheng Sun ◽  
Yang Wang

Experimental study on resistance of air-water two-phase flow in a vertical 3 × 3 rod bundle was carried out under normal temperature and pressure. The rod diameter and pitch were 8 mm and 11 mm, respectively. The ranges of gas and liquid superficial velocity were 0.013∼3.763 m/s and 0.076∼1.792 m/s, respectively. The result indicated that the existing correlations for calculating frictional coefficient in the rod bundle and local resistance coefficient could not give favorable predictions on the single-phase experimental data. For the case of two-phase flow, eight correlations for calculating two-phase equivalent viscosity poorly predicted the frictional pressure drop, with the mean absolute errors around 60%. Meanwhile, the eight classical two-phase viscosity formulae were evaluated against the local pressure drop at spacer grid. It is shown that Dukler model predicted the experimental data well in the range of Rel<9000 while McAdams correlation was the best for Rel⩾9000. For all the experimental data, Dukler model provided the best prediction with MRE of 29.03%. Furthermore, approaches to calculate two-phase frictional pressure drop and local resistance were proposed by considering mass quality, two-phase Reynolds number and densities in homogenous flow model, resulting in a good agreement with the experimental data.


Author(s):  
Zong-bao Gu ◽  
Yu Guo ◽  
Xiang Ma ◽  
Yan He ◽  
Wei Li

Abstract An experimental investigation for evaporation frictional pressure drop in horizontal enhanced tubes with an outer diameter of 12.7 mm was studied using R410A as the working fluid. The experiment was conducted: the mass flux in the range of 100 kg/(m2s) to 200 kg/(m2s), over a vapor quality range of 0.2 to 0.8, an average saturation temperature at 279 K. The inner tubes were the tested tubes, which included a smooth tube, a three-dimensional enhanced tube (a tube enhanced by protrusions and petal arrays background patterns), respectively. The results show that the frictional pressure drop increases with the mass flux increasing. Moreover, the frictional pressure drop of the enhanced tube is 1.6∼2.4 times than that of the smooth tube. This is mainly due to the increase of the flow resistance inside the enhanced tube, which is caused by the increased interfacial turbulence, flow separation and secondary flow. It is also observed that the pressure drop increases with vapor quality increasing. In addition, some existing correlations are used to compare with our experimental data and verify their accuracy. A new modified correlation is proposed to predict the frictional pressure drop of EHT-1 tube.


2019 ◽  
Vol 27 (04) ◽  
pp. 1950037
Author(s):  
Qais Abid Yousif ◽  
Normah Mohd-Ghazali ◽  
Agus Sunjarianto Pamitran ◽  
Yushazaziah Mohd-Yunos

Accurate prediction of the friction factor and consequently the pressure drop of two-phase flow in small channels is still an issue. Many correlations exist for the determination of the viscosity and the friction factor that appear in the frictional pressure drop and their combination often determined the degree of disagreements between the experimental data and predicted outcomes. Demands for environmentally friendly refrigerants have further posed a challenge to find compatible alternatives with as good a performance as the current coolants. Despite the many available correlations developed to date, many more are studied in effort to reduce the discrepancies. This paper presents the outcomes of a study comparing the optimized conditions when three different viscosity equations are paired with eight different friction factor correlations to minimize the frictional pressure drop. The approach used multi-objective genetic algorithm (MOGA) to assist in selecting the best pairing. Comparison is then completed with available experimental data. The study showed that the Blasius friction factor paired with the Dukler viscosity produced the least percentage difference for R22, while when paired with the McAdams viscosity produced a lower difference for R290, an environmentally friendly refrigerant being considered to replace R22.


Author(s):  
Xia-Xin Cao ◽  
Chang-Qi Yan ◽  
Pu-Zhen Gao ◽  
Zhong-Ning Sun

A series of experimental studies of frictional pressure drop for single phase and two-phase bubble flow in smooth rolling tubes were carried out. The tube inside diameters were 15mm, 25mm and 34.5mm respectively, the rolling angles of tubes could be set as 10° and 20°, and the rolling periods could be set as 5s, 10s and 15s. Combining with the analysis of single-phase water motion, it was found that the traditional correlations for calculating single-phase frictional coefficient were not suitable for the rolling condition. Based on the experimental data, a new correlation for calculating single-phase frictional coefficient under rolling condition was presented, and the calculations not only agreed well with the experimental data, but also could display the periodically dynamic characteristics of frictional coefficients. Applying the new correlation to homogeneous flow model, two-phase frictional pressure drop of bubble flow in rolling tubes could be calculated, the results showed that the relative error between calculation and experimental data was less than ± 25%.


Author(s):  
Clement C. Tang ◽  
Sanjib Tiwari ◽  
Afshin J. Ghajar

Experimental data for the void fraction and two-phase frictional pressure drop from various sources has been compiled and analyzed. The experimental data revealed that at the lower range of superficial gas velocity and void fraction, the variations of the two-phase frictional pressure drop with superficial gas velocity and void fraction are relatively flat. However, as the superficial gas velocity and void fraction increase to higher values, the frictional pressure drop became significantly sensitive to the two parameters. In a situation when the two-phase pressure drop is sensitive to the variation of the void fraction, it is then that the proper and accurate characterization of the void fraction becomes significant. From the experimental data, regions where the pressure drop is sensitive to the variation of the void fraction are identified and evaluated.