The Effect of Different Sterilization Methods on Polypropylene Syringes

2018 ◽  
Vol 12 (2) ◽  
Author(s):  
N. Selcan Turker ◽  
A. Yekta Özer ◽  
Burak Kutlu ◽  
Rahime Nohutcu ◽  
Seyda Colak ◽  
...  

This presents the influence of gamma irradiation on Pharmacopeia specifications, mechanical and flow parameters of polypropylene (PP) syringes. There has been significant progress in the terminal sterilization of single-use, disposable medical devices with gamma radiation sterilization due to the growing awareness of toxic residues during the ethylene oxide (EtO) sterilization. PP is a widely used polymer for the production of syringes because of its excellent mechanical and thermal properties and has expanded continuously over the last decade. Although 25 kGy was generally recommended for the gamma radiation sterilization of medical products, this radiation dose is high enough to produce substantial damage. Electron spin resonance (ESR) characteristics of irradiated syringes were also studied at normal (25 °C, 60% relative humidity) and accelerated (40 °C, 75% relative humidity) stability test conditions. It was found that the chemical and radiolytic changes and sterility assurance levels (SAL) after gamma radiation sterilization were different in PP syringes. It was shown that for two commercial syringes, E1 and E3, a SAL of 10−4 could be attained with only 10 kGy, with there being less detrimental radiation effects on E1. The differences in the radiosensitivity of the propylene syringes could be due to the different formulations and manufacturing processes. The results indicated that a commercial syringe, identified as E1 could be safely sterilized with gamma irradiation as the radicals decay over a period of days under normal conditions and quenched much faster under stability conditions. Furthermore, ESR technique could be used successfully in monitoring the radiosterilization of this material. Additionally, the confirmation and validation of the SAL doses which are below 25 kGy, will decrease the time and cost of the sterilization with less damaging effects of ionizing irradiation.

2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Dejan Nikolić ◽  
Koviljka Stanković ◽  
Ljubinko Timotijević ◽  
Zoran Rajović ◽  
Miloš Vujisić

This paper presents the behavior of various optoelectronic devices after gamma irradiation. A number of PIN photodiodes, phototransistors, and solar panels have been exposed to gamma irradiation. Several types of photodiodes and phototransistors were used in the experiment.I-Vcharacteristics (current dependance on voltage) of these devices have been measured before and after irradiation. The process of annealing has also been observed. A comparative analysis of measurement results has been performed in order to determine the reliability of optoelectronic devices in radiation environments.


Author(s):  
K. Cowden ◽  
B. Giammara ◽  
T. Devine ◽  
J. Hanker

Plaster of Paris (calcium sulfate hemihydrate, CaSO4. ½ H2O) has been used as a biomedical implant material since 1892. One of the primary limiting factors of these implants is their mechanical properties. These materials have low compressive and tensile strengths when compared to normal bone. These are important limiting factors where large biomechanical forces exist. Previous work has suggested that sterilization techniques could affect the implant’s strength. A study of plaster of Paris implant mechanical and physical properties to find optimum sterilization techniques therefore, could lead to a significant increase in their application and promise for future use as hard tissue prosthetic materials.USG Medical Grade Calcium Sulfate Hemihydrate Types A, A-1 and B, were sterilized by dry heat and by gamma radiation. Types A and B were additionally sterilized with and without the setting agent potassium sulfate (K2SO4). The plaster mixtures were then moistened with a minimum amount of water and formed into disks (.339 in. diameter x .053 in. deep) in polyethylene molds with a microspatula. After drying, the disks were fractured with a Stokes Hardness Tester. The compressive strengths of the disks were obtained directly from the hardness tester. Values for the maximum tensile strengths σo were then calculated: where (P = applied compression, D = disk diameter, and t = disk thickness). Plaster disks (types A and B) that contained no setting agent showed a significant loss in strength with either dry heat or gamma radiation sterilization. Those that contained potassium sulfate (K2SO4) did not show a significant loss in strength with either sterilization technique. In all comparisons (with and without K2SO4 and with either dry heat or gamma radiation sterilization) the type B plaster had higher compressive and tensile strengths than that of the type A plaster. The type A-1 plaster however, which is specially modified for accelerated setting, was comparable to that of type B with K2SO4 in both compressive and tensile strength (Table 1).


2018 ◽  
pp. 37-40
Author(s):  
Phuong Thao Tien Nguyen ◽  
Anh Hung Tran ◽  
Van Tam Le ◽  
Huu Thao Phung ◽  
Phan Quynh Anh Nguyen

Objective: To evaluate the effect of gamma sterilization and its effect on microscopic structure of deeply frozen dog skull. Subjects and methods: 50 pairs of dog skull fragments have the same size,which were taken symmetrically through the midline of the skull, were divided into two lots. Evident lot consisting of 50 pieces are just deeply frozen, not irradicated. Experimental lot which was composed of 50 pieces were deeply frozen and exposed to 25kGy of gamma radiation. Afterwards, to evaluate the effect of gamma sterilization and compare the alter of bone matrix between lot groups. Results: After gamma irradiation, all dog skull fragments were negative with bacteriological examination. In microscopic scale, no difference was found between the two lots and there was no structural change in the irradiated fragments of all dog skull. Conclusion: Gamma irradiation with 25 kGy: (i) It has the ability to kill bacteria completely in the type of bacteria commonly infected tissue. (ii) It does not alter the structure of dog skull in microstructures. Key words: dog skull, gamma, sterilize


2012 ◽  
Vol 60 (12) ◽  
pp. 3693-3698 ◽  
Author(s):  
Jincan Zhang ◽  
Yuming Zhang ◽  
Hongliang Lu ◽  
Yimen Zhang ◽  
Min Liu

1991 ◽  
Vol 178 (1-3) ◽  
pp. 11-14 ◽  
Author(s):  
L. Luo ◽  
Y.H. Zhang ◽  
S.H. Hu ◽  
W.H. Liu ◽  
G.L. Zhang ◽  
...  

2014 ◽  
Vol 95 ◽  
pp. 385-388 ◽  
Author(s):  
E.S. Ferreira ◽  
K.A. Gonçalves ◽  
J. Mitani ◽  
M. Yee ◽  
S.H. Tatumi

2014 ◽  
Vol 895 ◽  
pp. 567-570
Author(s):  
Azman Jalar ◽  
Wan Yusmawati Wan Yusoff ◽  
Norinsan Kamil Othman ◽  
Irman Abdul Rahman

Effect of gamma radiation (1.33 MeV) and high temperature storage of semiconductor package towards micromechanical properties has been investigated. The in-house fabricated Quad Flat No Lead was exposed to gamma radiation with the dose of 5 Gy. Afterwards, high temperature storage was performed at 150 °C for 10, 100 and 1000 hours. Subsequently, the three point bending technique was carried out to obtain the micromechanical properties of semiconductor package. The fracture of the packages caused by three point bending test was subjected to 3D CT scan to capture the image of the fracture. Irradiated package shows the decreasing in their strength with increasing doses of gamma radiation. However, the strength of the package was improved after high temperature storage for 10 hours and decreased as the storage period is extended. Further analysis exhibited that high temperature storage for 10 hours is reveal as good thermal treatment for package in radioactive environment application.


Sign in / Sign up

Export Citation Format

Share Document