scholarly journals Isotropic Failure Criteria Are Not Appropriate for Anisotropic Fibrous Biological Tissues

2017 ◽  
Vol 139 (7) ◽  
Author(s):  
Christopher E. Korenczuk ◽  
Lauren E. Votava ◽  
Rohit Y. Dhume ◽  
Shannen B. Kizilski ◽  
George E. Brown ◽  
...  

The von Mises (VM) stress is a common stress measure for finite element models of tissue mechanics. The VM failure criterion, however, is inherently isotropic, and therefore may yield incorrect results for anisotropic tissues, and the relevance of the VM stress to anisotropic materials is not clear. We explored the application of a well-studied anisotropic failure criterion, the Tsai–Hill (TH) theory, to the mechanically anisotropic porcine aorta. Uniaxial dogbones were cut at different angles and stretched to failure. The tissue was anisotropic, with the circumferential failure stress nearly twice the axial (2.67 ± 0.67 MPa compared to 1.46 ± 0.59 MPa). The VM failure criterion did not capture the anisotropic tissue response, but the TH criterion fit the data well (R2 = 0.986). Shear lap samples were also tested to study the efficacy of each criterion in predicting tissue failure. Two-dimensional failure propagation simulations showed that the VM failure criterion did not capture the failure type, location, or propagation direction nearly as well as the TH criterion. Over the range of loading conditions and tissue geometries studied, we found that problematic results that arise when applying the VM failure criterion to an anisotropic tissue. In contrast, the TH failure criterion, though simplistic and clearly unable to capture all aspects of tissue failure, performed much better. Ultimately, isotropic failure criteria are not appropriate for anisotropic tissues, and the use of the VM stress as a metric of mechanical state should be reconsidered when dealing with anisotropic tissues.

Author(s):  
Haolei Mou ◽  
Zhenyu Feng ◽  
Jiang Xie ◽  
Jun Zou ◽  
Kun Zhou

AbstractTo analysis the failure and energy absorption of carbon fiber reinforced polymer (CFRP) thin-walled square tube, the quasi-static axial compression loading tests are conducted for [±45]3s square tube, and the square tube after test is scanned to further investigate the failure mechanism. Three different finite element models, i.e. single-layer shell model, multi-layer shell model and stacked shell mode, are developed by using the Puck 2000 matrix failure criterion and Yamada Sun fiber failure criterion, and three models are verified and compared according to the experimental energy absorption metrics. The experimental and simulation results show that the failure mode of [±45]3s square tube is the local buckling failure mode, and the energy are absorbed mainly by intralaminar and interlaminar delamination, fiber elastic deformation, fiber debonding and fracture, matrix deformation cracking and longitudinal crack propagation. Three different finite element models can reproduce the collapse behaviours of [±45]3s square tube to some extent, but the stacked shell model can better reproduce the failure mode, and the difference of specific energy absorption (SEA) is minimum, which shows the numerical simulation results are in better agreement with the test results.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Pranav Lanka ◽  
Kalloor Joseph Francis ◽  
Hindrik Kruit ◽  
Andrea Farina ◽  
Rinaldo Cubeddu ◽  
...  

AbstractAccurate monitoring of treatment is crucial in minimally-invasive radiofrequency ablation in oncology and cardiovascular disease. We investigated alterations in optical properties of ex-vivo bovine tissues of the liver, heart, muscle, and brain, undergoing the treatment. Time-domain diffuse optical spectroscopy was used, which enabled us to disentangle and quantify absorption and reduced scattering spectra. In addition to the well-known global (1) decrease in absorption, and (2) increase in reduced scattering, we uncovered new features based on sensitive detection of spectral changes. These absorption spectrum features are: (3) emergence of a peak around 840 nm, (4) redshift of the 760 nm deoxyhemoglobin peak, and (5) blueshift of the 970 nm water peak. Treatment temperatures above 100 °C led to (6) increased absorption at shorter wavelengths, and (7) further decrease in reduced scattering. This optical behavior provides new insights into tissue response to thermal treatment and sets the stage for optical monitoring of radiofrequency ablation.


2014 ◽  
Vol 1648 ◽  
Author(s):  
Michael Culler ◽  
Keri A. Ledford ◽  
Jason H. Nadler

ABSTRACTRemora fish are capable of fast, reversible and reliable adhesion to a wide variety of both natural and artificial marine hosts through a uniquely evolved dorsal pad. This adhesion is partially attributed to suction, which requires a robust seal between the pad interior and the ambient environment. Understanding the behavior of remora adhesion based on measurable surface parameters and material properties is a critical step when creating artificial, bio-inspired devices. In this work, structural and fluid finite element models (FEM) based on a simplified “unit cell” geometry were developed to predict the behavior of the seal with respect to host/remora surface topology and tissue material properties.


Author(s):  
R. Villavicencio ◽  
Bin Liu ◽  
Kun Liu

The paper summarises observations of the fracture response of small-scale double hull specimens subjected to quasi-static impact loads by means of simulations of the respective experiments. The collision scenarios are used to evaluate the discretisation of the finite element models, and the energy-responses given by various failure criteria commonly selected for collision assessments. Nine double hull specimens are considered in the analysis so that to discuss the advantages and disadvantages of the different failure criterion selected for the comparison. Since a large scatter is observed from the numerical results, a discussion on the reliability of finite element analysis is also provided based on the present study and other research works found in the literature.


1969 ◽  
Vol 20 (1) ◽  
pp. 57-60 ◽  
Author(s):  
R. E. Little

SummaryNishihara’s combined bending and torsion out-of-phase fatigue limit data are analysed. The Tresca shear stress failure criterion predicts strengths up to 30 per cent higher than observed. It thus appears that renewed attention should be given to the basic problem of developing reliable combined stress failure criteria. It is suggested that new test methods will be required for this purpose.


2015 ◽  
Vol 2015 ◽  
pp. 1-13 ◽  
Author(s):  
Changxing Zhu ◽  
Hongbo Zhao ◽  
Zhongliang Ru

A rock failure criterion is very important for the prediction of the failure of rocks or rock masses in rock mechanics and engineering. Least squares support vector machines (LSSVM) are a powerful tool for addressing complex nonlinear problems. This paper describes a LSSVM-based rock failure criterion for analyzing the deformation of a circular tunnel under differentin situstresses without assuming a function form. First, LSSVM was used to represent the nonlinear relationship between the mechanical properties of rock and the failure behavior of the rock in order to construct a rock failure criterion based on experimental data. Then, this was used in a hypothetical numerical analysis of a circular tunnel to analyze the mechanical behavior of the rock mass surrounding the tunnel. The Mohr-Coulomb and Hoek-Brown failure criteria were also used to analyze the same case, and the results were compared; these clearly indicate that LSSVM can be used to establish a rock failure criterion and to predict the failure of a rock mass during excavation of a circular tunnel.


1999 ◽  
Author(s):  
B. R. Simon ◽  
S. K. Williams ◽  
J. Liu ◽  
J. W. Nichol ◽  
P. H. Rigby ◽  
...  

Abstract A soft hydrated tissue structure can be viewed as a “PETS” (poroelastic-transport-swelling) model, i.e., as a continuum composed of an incompressible porous solid (fibrous matrix with fixed charge density, FCD) that is saturated by a mobile incompressible fluid (water) containing mobile positively (p) and negatively (m) charged species. Previously, we described two PETS models — a “semi-mixed” porohyperelastic PHETS model (Simon et al. 1998) and a “fully mixed” MPHETS model (Simon et al. 1999) using FEMs (finite element models) that included geometric and material nonlinearity and coupled electrical/chemical/mechanical transport of the fluid and charged species. Here, we demonstrate the equivalence of the PHETS and MPHETS formulations that are useful when the solid and fluid materials are incompressible and the electrical-chemical potential and mechanical-osmotic pressure fields are discontinuous at material interfaces.


2012 ◽  
Vol 2012 (1) ◽  
pp. 000066-000072
Author(s):  
Erin Kimura ◽  
Jianbiao Pan

The appropriate selection of failure criterion for solder joint studies is necessary to correctly estimate reliability life. The objective of this study is to compare the effect of different failure criteria on the reliability life estimation. The four failure criteria in this study are a 20% resistance increase defined in the IPC-9701A standard, a resistance beyond 500Ω, an infinite resistance (hard open), and a failure criterion based on X̄ and R control charts. Accelerated thermal cycling conditions of a low-silver BGA study included 0°C to 100 °C with ten minute dwell times and −40°C to 125°C with ten minute dwell times. The results show that the life estimation based on X̄ and R failure criterion is very similar to the life estimation when a 20% resistance increase defined in the IPC-9701A failure criterion is used. The results also show that the reliability life would be overestimated if the failure criterion of a resistance threshold of 500Ω or an infinite resistance (hard open) is used.


2014 ◽  
Vol 670-671 ◽  
pp. 445-448
Author(s):  
Guo Jun Liu

In the civil engineering structures, when concrete structure withstand external loads, internal defects such as micro-cracks gradually developed, eventually will lead to the destruction of the concrete. Currently, there are two types of strength failure criterion of concrete, strength failure criterion based on stress-space and strength failure criterion based on strain-space, both of which have advantages and disadvantages, this paper introduces the research status of the two strength failure criteria of concrete, and the problems need further study in the future. It plays a strong practical significance in scientific research.


Sign in / Sign up

Export Citation Format

Share Document