An Experimental Performance Evaluation of a Cold-Region Photovoltaic System With Tracking

2017 ◽  
Vol 139 (3) ◽  
Author(s):  
Wongyu Choi ◽  
Michael B. Pate ◽  
Ryan D. Warren ◽  
Ron M. Nelson

A grid-connected dual-axis tracking photovoltaic (PV) system was installed in the Upper Midwest of the U.S., defined as a cold region, and then evaluated and monitored for a 1 year period. This system serves as a real-world application of PV for electricity generation in a region long overlooked for PV research studies. Additionally, the system provides an opportunity for research, demonstration, and education of dual-axis tracking PV, again not commonly studied in cold regions. In this regard, experimental data for the system were collected and analyzed over a 1year period. During the year of operation, the PV system collected a total of 2173 kWh/m2, which equates to 5.95 kWh/m2 on average per day, of solar insolation and generated a total of 1815 kWh, which equates to an energy to rated power ratio of 1779 kWh/kWp of usable AC electrical energy. The system operated at an annual average conversion efficiency and performance ratio of 11% and 0.82%, respectively, while the annual-average conversion efficiency of the inverter was 92%. The tracking system performance is also compared to a stationary PV system, which is located in close proximity to the tracking PV system. The tracking system's conversion efficiency was 0.3% higher than the stationary system while the energy generation per capacity was 40% higher although the PV module conversion efficiencies were not significantly different for the two systems.

2018 ◽  
Vol 7 (2.25) ◽  
pp. 143
Author(s):  
Bhuvaneswari C ◽  
Vijay B ◽  
Natarajan P

The primary and most universal measure of all kinds of work by nature is the energy. Coal, Natural gas, Oil and Nuclear energy are net energy yielders and primary sources of energy. The intent of this paper is to assess the performance of 15KW solar power plant installed in Priyadarshini Engineering College (PEC) campus, Vaniyambadi, Vellore District, Tamil Nadu. A 15 kW solar PV plant has been installed to supply electricity to the internet laboratory and library (lighting load). The results obtained from monitoring a 15 KW Solar Photovoltaic system installed on a library roofing of 10m height building. The system was monitored between (July-Sep2016) from 9.30AM to 4.30PM for three days in a week from Monday to Wednesday. The results can be used to provide manufacturers to develop their products and enhance the knowledge in the future in order to improve the design of the off-grid solar photovoltaic system, return of investment during these years. This work focuses on the performance of the solar photovoltaic plant (July-Sep2016) monthly average demand and annual performance parameters, Efficiency, fill factor,capacity Utilisation factor and the characteristics have been plotted in a graph. The graph is drawn between Generated power vs consumed power. The annual yield of the solar photovoltaic plant ranged from 6500-7000 Kwh and performance ratio of 78%. It has capacity Utilisation factor with 6.97%. 


2022 ◽  
Vol 14 (2) ◽  
pp. 627
Author(s):  
Muhammad Tamoor ◽  
Salman Habib ◽  
Abdul Rauf Bhatti ◽  
Arslan Dawood Butt ◽  
Ahmed Bilal Awan ◽  
...  

The focus of this research is to design a ground-mounted photovoltaic system at optimal tilt angle and interrow space to meet high demand of electrical energy. The Department of Electrical Engineering and Technology, GC University Faisalabad has been considered to perform the simulation test. This study is conducted using Meteonorm software for solar resource assessment. Furthermore, HelioScope software is used for modeling of a ground-mounted photovoltaic system, study of PV system’s performance in terms of annual generation, system losses and performance ratio and analysis of photovoltaic module’s performance, current-voltage and power-voltage curves for different irradiance levels. From SLD, it is seen that 11 strings are connected to each inverter and inverters output power are combined by using 20.0 A circuit interconnects. The performance of photovoltaic systems is impacted by tilt angle and interrow spacing. From simulation results of all cases, it is concluded that the PV system installed at 15° tilt angle with 4 feet interrow spacing are more efficient than the other installed PV systems, because total collector irradiance is maximum (1725.0 kWh/m2) as compared to other tilt angles. At 15° tilt angle, the annual production of photovoltaic system is 2.265 GWh and performance ratio of PV system is 82.0%. It is envisioned that this work will provide the guidance to energy system designers, planners and investors to formulate strategies for the installation of photovoltaic energy systems in Pakistan and all over the world.


2019 ◽  
Author(s):  
Rishal Asri

Sunlight is energy that can be converted into electrical energy. One of the uses is by applying it to the roof ofthe building. The application in this building has restrictions such as the placement of the PV moduleshorizontally and vertically. In the study comparing the results of energy obtained from the PV system withhorizontal and vertical positions with a standard degree angle in the direction of azimuth sunlight. Positionusing the horizontal produces more energy and reaches a performance ratio of more than 80%.


2019 ◽  
Vol 9 (1) ◽  
pp. 141 ◽  
Author(s):  
Slawomir Gulkowski ◽  
Agata Zdyb ◽  
Piotr Dragan

This study presents a comparative analysis of energy production over the year 2015 by the grid connected experimental photovoltaic (PV) system composed by different technology modules, which operates under temperate climate meteorological conditions of Eastern Poland. Two thin film technologies have been taken into account: cadmium telluride (CdTe) and copper indium gallium diselenide (CIGS). Rated power of each system is approximately equal to 3.5 kWp. In addition, the performance of a polycrystalline silicon technology system has been analyzed in order to provide comprehensive comparison of the efficiency of thin film and crystalline technologies in the same environmental conditions. The total size of the pc-Si system is equal to 17 kWp. Adequate sensors have been installed at the location of the PV system to measure solar irradiance and temperature of the modules. In real external conditions all kinds of modules exhibit lower efficiency than the values provided by manufacturers. The study reveals that CIGS technology is characterized by the highest energy production and performance ratio. The observed temperature related losses are of the lowest degree in case of CIGS modules.


2012 ◽  
Vol 517 ◽  
pp. 791-796
Author(s):  
Cheng Yao Wang ◽  
Yin Xu ◽  
Yao Ming Zhang ◽  
Yong Ming Hua

In this paper, a concentrating photovoltaic (CPV) system with low ratio was successfully developed. In the design of CPV concentrator, a quasi-parabolic reflector was adopted. With the research of basic optical mechanisms, a mathematic model was built with the corresponding program. In addition, the width of light spot was analyzed with considering the symmetry of tracking errors and glass deformation in manufacture to identify reasonable values. The system was designed with a reflector of 10 flat mirrors, which has a geometrical concentration ratio of 8.18 and a flux concentration ratio of 5. The concentrating photovoltaic system was investigated experimentally under the various weather conditions. The output voltage profile and the output power of the flat PV system and the CPV system were presented to analyze the concentration ratio and the electric power. And the influence of soiling was also discussed. The results showed that the performance of tracking system was good in a clear day. Compared to the flat cell with the same system, the electric power was nearly increased by 4-5 times.


2021 ◽  
Author(s):  
Williams S. Ebhota ◽  
Pavel Y. Tabakov

Abstract A rooftop solar photovoltaic (PV) system is an alternative electricity source that is increasingly being used for households. The potential of solar PV is location dependent that needs to be assessed before installation. This study focuses on the assessment of a solar PV potential of a site on coordinates − 29.853762°, 031.00634°, at Glenmore Crescent, Durban North, South Africa. In addition, it evaluates the performance of a 6 kW installed capacity grid-connected rooftop solar PV system to supply electricity to a household. The results, obtained from PV design and simulation tools – PV*SOL, Solargis prospect and pvPlanner, were used to analyse and establish the site and PV system technical viability. The system’s configuration is as follows: load profile - a 2-Person household with 2-children, energy consumption − 3500 kWh, system size − 6 kWp, installation type - roof mount, PV module type - c-Si - monocrystalline silicon, efficiency − 18.9%, orientation of PV modules -Azimuth 0° and Tilt 30°, inverter 95.9% (Euro efficiency), and no transformer. The results show: meteorological parameters - global horizontal irradiation (GHI) 1659.3 kWh/m2, direct normal irradiation (DNI) 1610.6 kWh/m2, air temperature 20.6°C; performance parameters - annual PV energy 8639 kWh, Specific annual yield 1403 kWh/kWp, performance ratio (PR) 74.9%, avoided CO₂ emissions 5662 kg/year, and solar fraction 42.5 %. The analysis and benchmarking of the results show that the proposed solar PV system under the current conditions is technically viable for household electrification in Durban North, South Africa.


Author(s):  
Saminathan S & Dr. Ranjithkumar K

In this work, a new modular multilevel inverter topology is introduced for a single phase grid connected Photovoltaic system. This multilevel inverter use less number of switches to generate seven levels compared to other conventional multilevel inverters. This requires only one isolated dc source to operate. So it is suitable for renewable energy application. This inverter is designed by submodule configuration; each sub module contains two switches and one DC link capacitor. The sub modules will be added to the inverter depending on number of levels. The voltage balancing of DC link capacitor is carried out by Y matrix PWM technique. Because of Y matrix PWM technique, the inverter gets a self capacitor voltage balancing ability. So there is no need of external devices required for balancing the voltage of capacitor. A PLL for grid integration and LCL filter are designed and integrated with this inverter. The simulation of proposed system is carried out by MATLAB/SIMULINK and performance of THD is monitored as per standards


2021 ◽  
Vol 302 ◽  
pp. 01006
Author(s):  
Sukkhi Buakaew ◽  
Prayut Jiamrittiwong ◽  
Nutdechatorn Puangngernmak

Renewable energy as a solar photovoltaic system represents an essential role in improving and promoting energy sustainability in agricultural/aquaculture-related activities. The “Crab Bank” is the program on practicing the caught gravid females of Blue Swimming Crab (BSC) in supporting conditions, allowing them to spawn and then release the zoea and young crabs back to the sea where are in the Eastern Economic Corridor (EEC). Onward with the project, many scientific studies assess the BSC stocks condition, evaluate the fishing habitat, and other relevant issues as the energy used in a micro-indoor system as Recirculating Aquaculture Systems (RAS). The off-grid solar photovoltaic system is used in the system cause the installed location was near the seaside area. The system’s large size was operating, including solar panels, inverter, charger, and batteries to maintain the AC motor pump, affecting much energy loss in the system. The off-grid solar system design for modular systems is represented in this paper to describe the new structure of the micro modular RAS that reduces cost and increases the solar system’s efficiency in modular concepts comparing the traditional system. The new structure model represents the calculation result in the term of electrical energy and experiment to scale for replacement in the aquaculture area in Rayong or Jantaburi in the EEC region. This research is a cooperation between KMUTNB Rayong and the Provincial Energy Office Of Rayong.


Author(s):  
Ashish Grover ◽  
Anita Khosla ◽  
Dheeraj Joshi

<p>This   paper deeply explains the analysis through simulation and sizing of grid connected photovoltaic plant of 20MW for the site Devdurga, Karnataka India with use of PV syst software tool. Primarily, the trajectories the behavior of grid tied photovoltaic system at a particular location. It gives results for the geographical position taken by maps for avoiding the oversizing or under sizing of the systems which projects the installation with very much realistic conditions. The projected area is of about 110 acres would generate 44854 MWh/year for a 20MW PV system, with a performance ratio of 76.28%.Loss fraction taken for simulation and sizing is 2%.The paper also includes the study and behavior of the system   with tilt and orientation of the PV Panel which gives better simulation results at similar latitudes for any feasible sizing.</p>


2018 ◽  
Vol 7 (3.15) ◽  
pp. 145
Author(s):  
S Z.Mohammad Noor ◽  
S Zaini ◽  
A M.Omar

This work presents a design of graphical user interface development environment (GUIDE) software for sizing of Grid Connected Photovoltaic (GCPV) system. The simulation model of the GCPV system design is developed by using GUIDE in MATLAB. The developed GUI display the performance of the PV system based on the three scenarios. The three scenarios are sizing based on architecture constraint, the energy required and budget constraint. The size of the GCPV system is from 4.6 kW to 60.0 kW. A GUIDE is developed to design and calculate the suitable size of photovoltaic (PV) module, analyses the optimum array configuration, selection of inverter, size of cable, determine the specific yield and performance ratio. The GUI be able to make a user’s job easier and beneficial in assisting the GCPV system design process compared to the manual calculation of the GCPV system.  


Sign in / Sign up

Export Citation Format

Share Document