Enhanced Compressive Sensing of Dielectric Elastomer Sensor Using a Novel Structure

2015 ◽  
Vol 82 (10) ◽  
Author(s):  
Junjie Liu ◽  
Guoyong Mao ◽  
Xiaoqiang Huang ◽  
Zhanan Zou ◽  
Shaoxing Qu

Dielectric elastomer (DE) can undergo large deformation when subjected to external forces or voltage, leading to the variation of the capacitance. A novel DE sensor is proposed to detect compressive force. This sensor consists of a series of elements made of DE membrane with out-of-plane deformation. Each element experiences highly inhomogeneous large deformation to obtain high sensitivity. Both experimental and theoretical studies are conducted to optimize the performance of the sensor element, and the effects of the prestretches and the aspect ratios on the sensitivity are achieved. Results from the theoretical analysis based on continuum mechanics agree well with the experimental data. Furthermore, the reliability of the sensor element is illustrated by additional experimental investigation on the operation after 2000 cyclic loadings. This study provides guidance for the design and performance analysis of soft sensors.

2014 ◽  
Vol 912-914 ◽  
pp. 981-988
Author(s):  
Lei Lei Cui ◽  
Li Li

Due to the capability of high strain, dielectric elastomers are promising for applications as transducers in cameras, robots, valves, pumps, energy harvesters and so on. This paper focuses on the large deformation analysis of a dielectric elastomer membrane.The membrane is initially flat and attached to a disk in the inner circle and to a rigid ring in the outer circle, then a weight is applied to the disk and the membrane deforms into an axisymmetric shape, undergoing large out-of-plane deformation. The membrane is assumed to behave elastically in accordance with the ogden law. The governing equations are derived by combining kinematics and thermodynamics and a set of ordinary differential equations (ODEs) are obtained finally. The ODEs are solved by using shooting method. The obtained results show that the deformation field in the membrane is very inhomogeneous.


2020 ◽  
Vol 39 (1) ◽  
pp. 209-221
Author(s):  
Jiafeng Wan ◽  
Xiaoyuan Zhang ◽  
Kai Zhang ◽  
Zhiqiang Su

Abstract In recent years, nanomaterials have attracted lots of attention from researchers due to their unique properties. Nanometer fluorescent materials, such as organic dyes, semiconductor quantum dots (QDs), metal nano-clusters (MNCs), carbon dots (CDs), etc., are widely used in biological imaging due to their high sensitivity, short response time, and excellent accuracy. Nanometer fluorescent probes can not only perform in vitro imaging of organisms but also achieve in vivo imaging. This provides medical staff with great convenience in cancer treatment. Combined with contemporary medical methods, faster and more effective treatment of cancer is achievable. This article explains the response mechanism of three-nanometer fluorescent probes: the principle of induced electron transfer (PET), the principle of fluorescence resonance energy transfer (FRET), and the principle of intramolecular charge transfer (ICT), showing the semiconductor QDs, precious MNCs, and CDs. The excellent performance of the three kinds of nano fluorescent materials in biological imaging is highlighted, and the application of these three kinds of nano fluorescent probes in targeted biological imaging is also introduced. Nanometer fluorescent materials will show their significance in the field of biomedicine.


2017 ◽  
Vol 20 (2) ◽  
pp. 85
Author(s):  
Pawan Whig ◽  
Syed Naseem Ahmad ◽  
Surinder Kumar

In this paper, a novel circuit is presented which overcome a serious limitation found in case of multiple sensors system. In this novel system design only one reference electrode and few active components used that makes the implementation of a low-cost system for the supervision of water quality. Photo Catalytic Sensor (PCS) estimates the parameter BOD (Biological Oxygen Demand) which is generally used to estimate quality of water. The system proposed in this paper involves a balanced bridge approach using few electronic components that provides a correlation in the input-output signals of low-cost sensors. The main reason of employing a readout circuit to PCS circuitry, is the fact that the fluctuation of O2 influences the threshold voltage, which is internal parameter of the FET and can manifest itself as a voltage signal at output but as a function of the trans conductance gain. The trans-conductance is a passive parameter and in order to derive voltage or current signal from its fluctuations the sensor has to be attached to readout circuit. This circuit provides high sensitivity to the changes in percentage of O2 in the solution.


1996 ◽  
Vol 199 (10) ◽  
pp. 2243-2252 ◽  
Author(s):  
E Drucker ◽  
J Jensen

In this study, we report the first allometric equations relating gait parameters and swimming speed to body size for fish employing pectoral fin locomotion. Comparisons of locomotor kinematics and performance among striped surfperch (Teleostei: Embiotocidae) are made at the pectoral­caudal gait transition speed (Up-c). Up-c is considered to elicit physiologically equivalent levels of exercise in animals varying over 100-fold in body mass (Mb) by virtue of dynamically similar pectoral fin movements (constant duty factor, length-specific stride length and fin-beat amplitude) and size-independent propulsive efficiency. At Up-c, pectoral fin-beat frequency scales in proportion to Mb-0.12±0.03, a size-dependence consistent with that observed for stride frequency in fishes swimming by axial undulatory propulsion and in many running tetrapods. It is proposed that the similarity in the scaling of frequency in these vertebrate groups reflects an underlying similarity in the allometry of the maximal velocity of muscle shortening. Absolute Up-c (m s-1) generally increases with body size, but the fastest speeds are not exhibited by the largest animals. A pattern of declining performance in fish 23 cm in standard length and longer may be related to their disproportionately small fin areas and aspect ratios. The pronounced negative allometry of Up-c expressed as standard body lengths per second indicates that a given length-specific speed does not induce comparable levels of activity in large and small fish. Thus, normalization of swimming speed to body length may not be a sufficient correction for kinematic comparisons across size.


2021 ◽  
Vol 15 (4) ◽  
pp. 118-131
Author(s):  
Sadiq A. Mehdi

In this paper, a novel four-dimensional chaotic system has been created, which has characteristics such as high sensitivity to the initial conditions and parameters. It also has two a positive Lyapunov exponents. This means the system is hyper chaotic. In addition, a new algorithm was suggested based on which they constructed an image cryptosystem. In the permutation stage, the pixel positions are scrambled via a chaotic sequence sorting. In the substitution stage, pixel values are mixed with a pseudorandom sequence generated from the 4D chaotic system using XOR operation. A simulation has been conducted to evaluate the algorithm, using the standardized tests such as information entropy, histogram, number of pixel change rate, unified average change intensity, and key space. Experimental results and performance analyses demonstrate that the proposed encryption algorithm achieves high security and efficiency.


2021 ◽  
Vol 21 (8) ◽  
pp. 4400-4405
Author(s):  
Junyeop Lee ◽  
Nam Gon Do ◽  
Dong Hyuk Jeong ◽  
Sae-Wan Kim ◽  
Maeum Han ◽  
...  

Carbon monoxide (CO) is an odorless, colorless, tasteless, extremely flammable, and highly toxic gas. It is produced when there is insufficient oxygen supply during the combustion of carbon to produce carbon dioxide (CO2). CO is produced from operating engines, stoves, or furnaces. CO poisoning occurs when CO accumulates in the bloodstream and can result in severe tissue damage or even death. Many types of CO sensors have been reported, including electrochemical, semiconductor metal-oxide, catalytic combustion, thermal conductivity, and infrared absorption-type for the detection of CO. However, despite their excellent selectivity and sensitivity, issues such as complexity, power consumption, and calibration limit their applications. In this study, a fabricbased colorimetric CO sensor is proposed to address these issues. Potassium disulfitopalladate (II) (K2Pd(SO3)2) is dyed on a polyester fabric as a sensing material for selective CO detection. The sensing characteristics and performance are investigated using optical instruments such as RGB sensor and spectrometer. The sensor shows immediate color change when exposed to CO at a concentration that is even lower than 20 ppm before 2 min. The fast response time of the sensor is attributed to its high porosity to react with CO. This easy-to-fabricate and cost-effective sensor can detect and prevent the leakage of CO simultaneously with high sensitivity and selectivity toward CO.


Micromachines ◽  
2020 ◽  
Vol 11 (2) ◽  
pp. 148 ◽  
Author(s):  
Francisco J. Romero ◽  
Almudena Rivadeneyra ◽  
Markus Becherer ◽  
Diego P. Morales ◽  
Noel Rodríguez

In this paper, we present a simple, fast, and cost-effective method for the large-scale fabrication of high-sensitivity humidity sensors on flexible substrates. These sensors consist of a micro screen-printed capacitive structure upon which a sensitive layer is deposited. We studied two different structures and three different sensing materials by modifying the concentration of poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT:PSS) in a graphene oxide (GO) solution. The results show that the aggregation of the PEDOT:PSS to the GO can modify its electrical properties, boosting the performance of the capacitive sensors in terms of both resistive losses and sensitivity to relative humidity (RH) changes. Thus, in an area less than 30 mm2, the GO/PEDOT:PSS-based sensors can achieve a sensitivity much higher (1.22 nF/%RH at 1 kHz) than other similar sensors presented in the literature which, together with their good thermal stability, time response, and performance over bending, demonstrates that the manufacturing approach described in this work paves the way for the mass production of flexible humidity sensors in an inexpensive way.


Sensor Review ◽  
2019 ◽  
Vol 39 (3) ◽  
pp. 417-432 ◽  
Author(s):  
A. Vivek ◽  
K. Shambavi ◽  
Zachariah C. Alex

Purpose This paper aims to focus on research work related to metamaterial-based sensors for material characterization that have been developed for past ten years. A decade of research on metamaterial for sensing application has led to the advancement of compact and improved sensors. Design/methodology/approach In this study, relevant research papers on metamaterial sensors for material characterization published in reputed journals during the period 2007-2018 were reviewed, particularly focusing on shape, size and nature of materials characterized. Each sensor with its design and performance parameters have been summarized and discussed here. Findings As metamaterial structures are excited by electromagnetic wave interaction, sensing application throughout electromagnetic spectrum is possible. Recent advancement in fabrication techniques and improvement in metamaterial structures have led to the development of compact, label free and reversible sensors with high sensitivity. Originality/value The paper provides useful information on the development of metamaterial sensors for material characterization.


2019 ◽  
Vol 803 ◽  
pp. 120-123
Author(s):  
Xiong Bang Wei ◽  
Guo Dong Lv ◽  
Xiao Hui Yang ◽  
Tao Wu ◽  
Dong Shi ◽  
...  

In this paper, a kind of novel TiO2 nanotube arrays (TNTs) hybrid structure was presented to improve the performance of hydrogen sensors. In this novel structure, palladium functionalized TNTs hybrid nanostructure supported on titanium wire. TNTs arrays was prepared by anodizing Ti wire using a standard electrochemical procedure. Pd nanomaterials were deposited on TNTs. Optimized experiments showed the hydrogen sensor supported on titanium wire showed a good response time of 8 s and high sensitivity of 94.8% at 1.9 vol% H2 at room temperature (25 °C). The research work revealed potential good hydrogen sensitivity of this kind of hybrid nanostructure.


Sign in / Sign up

Export Citation Format

Share Document