scholarly journals A New Sensor for Measurement of Dynamic Contact Stress in the Hip

2014 ◽  
Vol 136 (3) ◽  
Author(s):  
M. J. Rudert ◽  
B. J. Ellis ◽  
C. R. Henak ◽  
N. J. Stroud ◽  
D. R. Pederson ◽  
...  

Various techniques exist for quantifying articular contact stress distributions, an important class of measurements in the field of orthopaedic biomechanics. In situations where the need for dynamic recording has been paramount, the approach of preference has involved thin-sheet multiplexed grid-array transducers. To date, these sensors have been used to study contact stresses in the knee, shoulder, ankle, wrist, and spinal facet joints. Until now, however, no such sensor had been available for the human hip joint due to difficulties posed by the deep, bi-curvilinear geometry of the acetabulum. We report here the design and development of a novel sensor capable of measuring dynamic contact stress in human cadaveric hip joints (maximum contact stress of 20 MPa and maximum sampling rate 100 readings/s). Particular emphasis is placed on issues concerning calibration, and on the effect of joint curvature on the sensor's performance. The active pressure-sensing regions of the sensors have the shape of a segment of an annulus with a 150-deg circumferential span, and employ a polar/circumferential “ring-and-spoke” sensel grid layout. There are two sensor sizes, having outside radii of 44 and 48 mm, respectively. The new design was evaluated in human cadaver hip joints using two methods. The stress magnitudes and spatial distribution measured by the sensor were compared to contact stresses measured by pressure sensitive film during static loading conditions that simulated heel strike during walking and stair climbing. Additionally, the forces obtained by spatial integration of the sensor contact stresses were compared to the forces measured by load cells during the static simulations and for loading applied by a dynamic hip simulator. Stress magnitudes and spatial distribution patterns obtained from the sensor versus from pressure sensitive film exhibited good agreement. The joint forces obtained during both static and dynamic loading were within ±10% and ±26%, respectively, of the forces measured by the load cells. These results provide confidence in the measurements obtained by the sensor. The new sensor's real-time output and dynamic measurement capabilities hold significant advantages over static measurements from pressure sensitive film.

2015 ◽  
Vol 138 (1) ◽  
Author(s):  
Sunghwan Kim ◽  
Mark Carl Miller

A finite element (FE) elbow model was developed to predict the contact stress and contact area of the native humeroradial joint. The model was validated using Fuji pressure sensitive film with cadaveric elbows for which axial loads of 50, 100, and 200 N were applied through the radial head. Maximum contact stresses ranged from 1.7 to 4.32 MPa by FE predictions and from 1.34 to 3.84 MPa by pressure sensitive film measurement while contact areas extended from 39.33 to 77.86 mm2 and 29.73 to 83.34 mm2 by FE prediction and experimental measurement, respectively. Measurements from cadaveric testing and FE predictions showed the same patterns in both the maximum contact stress and contact area, as another demonstration of agreement. While measured contact pressures and contact areas validated the FE predictions, computed maximum stresses and contact area tended to overestimate the maximum contact stress and contact area.


Author(s):  
G A Matricali ◽  
L Labey ◽  
W Bartels ◽  
G Dereymaeker ◽  
F P Luyten ◽  
...  

Sealed pressure-sensitive film is frequently used to record contact characteristics in physiological joints. However, the effect on the pressure-recording characteristics of sealing the film when used in these circumstances has never been studied. This study compares the coefficient of variation, the standardized coefficient of variation, the tangent and secant contact stress gradients, and the actual pressures between unsealed and sealed Fuji film, in a simplified physiological joint model with a full-thickness surface defect. Unsealed film and sealed film were loaded through a range of nominal loads and the resulting stains were analysed by use of custom-made macros for the ImageJ image-processing program. The coefficient of variation did not exceed 5.7 per cent (sealed film), and the standardized coefficient of variation did not exceed 1.8 per cent (unsealed and sealed film). Contact stress gradients did not differ significantly. The recorded pressure at the level of surface defects was always about 0.2 MPa higher in the case of sealed film, and therefore predictable. It is concluded that sealing the film will not change the pressure-recording characteristics.


2020 ◽  
Vol 16 (3) ◽  
pp. 189-193
Author(s):  
David H. Wei ◽  
Peter Tang

The study of contact biomechanics of the wrist is a challenge. This is partly due to the relatively small size of the joint as well as the lack of space in the radiocarpal joint which makes the delivery of investigative materials such as pressure sensitive film without causing artifact, difficult. Fortunately, a number of authors have studied the intact wrist, the scapholunate ligament injured wrist, the proximal row carpectomy and the scaphoid excision, four bone fusion. Despite some contrasting findings, there are some general concepts that we understand about wrist mechanics.


Foot & Ankle ◽  
1992 ◽  
Vol 13 (4) ◽  
pp. 220-223 ◽  
Author(s):  
Alan S. Tuckman ◽  
Frederick W. Werner ◽  
Maria D. Fortino ◽  
Joseph A. Spadaro

Although a number of pathologies of the forefoot in ballet dancers on pointe have been described, pressures and deforming forces have not been adequately measured. To evaluate the possible use of pressure-sensitive film (PSF) in measuring the pressures on the external soft tissues in such a confined space as the dancer's toe shoe, it was tested and calibrated with 20 cadaver toes. Each cadaver toe was internally stabilized and loaded longitudinally against PSF on a flat surface. The resultant films were analyzed with a video imaging system and the pressures and total forces were determined. Results showed that the linearity of the PSF to pressure had a regression value of 0.98. By using two sensitivity ranges of films, the total force measured by the PSF was found to be within 10% of the known applied force on each toe. The PSF, therefore, may very well be a useful and accurate method of measuring external soft tissue pressures on the forefoot.


2009 ◽  
Vol 35 (1) ◽  
pp. 43-45 ◽  
Author(s):  
Y.-L. Zhu ◽  
Y.-Q. Xu ◽  
J. Ding ◽  
J. Li ◽  
B. Chen ◽  
...  

We investigated the biomechanics of the radiocapitate joint after a proximal row carpectomy in six fresh-frozen cadaver wrists using super-low-pressure-sensitive film on a material testing system. The average pressure within the lunate fossa increased significantly from 23.2 to 136.4 N/cm2 with a sharp decrease in the contact area from 2.08 to 0.30 cm2 after a proximal row carpectomy. The cartilage of the proximal capitate had four sub-facets and therefore was not as smooth as the normal proximal lunate. We found that the wrist was overloaded after a proximal row carpectomy and the main cause was the anatomical mismatch of the radiocapitate articulation.


2020 ◽  
Vol 142 (5) ◽  
Author(s):  
Adam R. Brink ◽  
Robert J. Kuether ◽  
Matthew D. Fronk ◽  
Bryan L. Witt ◽  
Brendan L. Nation

Abstract The member stiffness and pressure distribution in a bolted joint is significantly influenced by the contact area of the mechanical interface under a prescribed preload force. This research explores the influence of as-built surface profiles for nominally flat interfaces of a C-Beam assembly with two well-defined contact regions. A high-fidelity finite element model is created such that the model uncertainty is minimized by updating and calibrating the piece parts prior to the preload assembly procedure. The model is then assembled and preloaded to evaluate the contact stresses and contact area for both nominally flat and perturbed non-flat surfaces based on three-dimensional surface topography measurements. The predicted pressures are validated with digitized pressure-sensitive film measurements. The high-fidelity modeling reveals how the compliance and thickness of the pressure-sensitive film alter the measured pressures, leading to incorrect evaluations of the stresses and contact area in the joint. The resulting low-level dynamic behavior of the preloaded assembly is shown to be sensitive to the true contact area by linearizing the nonlinear finite element model about the preloaded equilibrium and performing a computational modal analysis. The resonant frequencies are validated with experimental measurements to demonstrate the effect of the contact area on the modal characteristics of the bolted assembly. Vibration modes and loading patterns exhibit varying levels of sensitivity to the contact area in the joint, leading to an improved physical understanding of the influence of contact mechanics on the low-level linear vibration modes of jointed assemblies.