scholarly journals Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film

Author(s):  
Gordon R. Plank ◽  
Daniel M. Estok ◽  
Orhun K. Muratoglu ◽  
Daniel O. O'Connor ◽  
Brian R. Burroughs ◽  
...  
Author(s):  
Ida Khosravipour ◽  
Shabnam Pejhan ◽  
Yunhua Luo ◽  
Urs P Wyss

Contact pressure and stresses on the articulating surface of the tibial component of a total knee replacement are directly related to the joint contact forces and the contact area. These stresses can result in wear and fatigue damage of the ultra-high-molecular-weight polyethylene. Therefore, conducting stress analysis on a newly designed surface-guided knee implant is necessary to evaluate the design with respect to the polyethylene wear. Finite element modeling is used to analyze the design’s performance in level walking, stair ascending and squatting. Two different constitutive material models have been used for the tibia component to evaluate the effect of material properties on the stress distribution. The contact pressure results of the finite element analysis are compared with the results of contact pressure using pressure-sensitive film tests. In both analyses, the average contact pressure remains below the material limits of ultra-high-molecular-weight polyethylene insert. The peak von Mises stresses in 90° of flexion and 120° of flexion (squatting) are 16.28 and 29.55 MPa, respectively. All the peak stresses are less than the fatigue failure limit of ultra-high-molecular-weight polyethylene which is 32 MPa. The average contact pressure during 90° and 120° of flexion in squatting are 5.51 and 5.46 MPa according to finite element analysis and 5.67 and 8.14 MPa according to pressure-sensitive film experiment. Surface-guided knee implants are aimed to resolve the limitations in activities of daily living after total knee replacement by providing close to normal kinematics. The proposed knee implant model provides patterns of motion much closer to the natural target, especially as the knee flexes to higher degrees during squatting.


2015 ◽  
Vol 138 (1) ◽  
Author(s):  
Sunghwan Kim ◽  
Mark Carl Miller

A finite element (FE) elbow model was developed to predict the contact stress and contact area of the native humeroradial joint. The model was validated using Fuji pressure sensitive film with cadaveric elbows for which axial loads of 50, 100, and 200 N were applied through the radial head. Maximum contact stresses ranged from 1.7 to 4.32 MPa by FE predictions and from 1.34 to 3.84 MPa by pressure sensitive film measurement while contact areas extended from 39.33 to 77.86 mm2 and 29.73 to 83.34 mm2 by FE prediction and experimental measurement, respectively. Measurements from cadaveric testing and FE predictions showed the same patterns in both the maximum contact stress and contact area, as another demonstration of agreement. While measured contact pressures and contact areas validated the FE predictions, computed maximum stresses and contact area tended to overestimate the maximum contact stress and contact area.


2011 ◽  
Vol 314-316 ◽  
pp. 1218-1221
Author(s):  
Hao Min Huang

Conventional methods of design to be completed ordinary hydraulic transmission gear gearbox design, but for such a non-planet-rule entity, and the deformation of the planet-gear contact stress will have a great impact on the planet gear, it will be very difficult According to conventional design. In this paper, ANSYS software to the situation finite element analysis, the planetary gear to simulate modeling study.


2014 ◽  
Vol 496-500 ◽  
pp. 1007-1011
Author(s):  
Jian Hua Fang ◽  
Wei Yan

The design of seal device that can be used in carbide actor is a real problems.This paper presents a kind of oblique-cone-slid-ring (OCSR) assembly seal device that can self-compensate the seal wear in application. The max contact stress on the seal surface and other contact face is far bigger than the work stress of sealed medium in carbide actor. That means the design satisfies the user demand . Keywords: oblique-cone-sliding-ring (OCSR) assembly seal; self-compensation to seal wear; finite element analysis; contact stress;


2001 ◽  
Author(s):  
Dorothy M. Murphy ◽  
Alan Kavanagh ◽  
Tim M. McGloughlin

Abstract Upon examination of failed total knee replacements, it has been concluded that it is the performance of the ultra high molecular weight polyethylene (UHMWPE) tibial component that governs the useful lifespan of such a joint. Severe wear of UHMWPE is associated more with tibial components of the knee than with the acetabular cups of total hip replacements. This is due to a notable lack of congruity between the articulating surfaces which leads to the presence of significant localised stresses in the femoro-tibial interface.


2013 ◽  
Vol 442 ◽  
pp. 229-232 ◽  
Author(s):  
Li Mei Wu ◽  
Fei Yang

According to the cutting theory of involute tooth profile, established an exact three-dimensional parametric model by UG. Used ABAQUS to crate finite element model for gear meshing. After simulated the meshing process, discussed the periodicity of the tooth surface contact stress. Based on the result of finite element analysis, made a comparison of the maximum contact stress between finite element solution and Hertz theoretical solution, analyzed the contact stress distribution on tooth width, and researched the effect of friction factor on contact stress. All that provided some theoretical basis for gear contact strength design.


2020 ◽  
Vol 142 (5) ◽  
Author(s):  
Adam R. Brink ◽  
Robert J. Kuether ◽  
Matthew D. Fronk ◽  
Bryan L. Witt ◽  
Brendan L. Nation

Abstract The member stiffness and pressure distribution in a bolted joint is significantly influenced by the contact area of the mechanical interface under a prescribed preload force. This research explores the influence of as-built surface profiles for nominally flat interfaces of a C-Beam assembly with two well-defined contact regions. A high-fidelity finite element model is created such that the model uncertainty is minimized by updating and calibrating the piece parts prior to the preload assembly procedure. The model is then assembled and preloaded to evaluate the contact stresses and contact area for both nominally flat and perturbed non-flat surfaces based on three-dimensional surface topography measurements. The predicted pressures are validated with digitized pressure-sensitive film measurements. The high-fidelity modeling reveals how the compliance and thickness of the pressure-sensitive film alter the measured pressures, leading to incorrect evaluations of the stresses and contact area in the joint. The resulting low-level dynamic behavior of the preloaded assembly is shown to be sensitive to the true contact area by linearizing the nonlinear finite element model about the preloaded equilibrium and performing a computational modal analysis. The resonant frequencies are validated with experimental measurements to demonstrate the effect of the contact area on the modal characteristics of the bolted assembly. Vibration modes and loading patterns exhibit varying levels of sensitivity to the contact area in the joint, leading to an improved physical understanding of the influence of contact mechanics on the low-level linear vibration modes of jointed assemblies.


Sign in / Sign up

Export Citation Format

Share Document