Influence of Unsteady Wake With Trailing Edge Coolant Ejection on Turbine Blade Film Cooling

2012 ◽  
Vol 134 (6) ◽  
Author(s):  
Shiou-Jiuan Li ◽  
Akhilesh P. Rallabandi ◽  
Je-Chin Han

Detailed film cooling effectiveness distributions along a modeled turbine rotor blade under the combined effects of an upstream trailing edge unsteady wake with coolant ejection are presented using the pressure sensitive paint (PSP) mass transfer analogy method. The experiment is conducted in a low speed wind tunnel facility with a five blade linear cascade. The exit Reynolds number based on the axial chord is 370,000. Unsteady wakes and trailing edge coolant jets are produced by a spoked wheel-type wake generator with hollow rods equipped with several coolant ejections from holes. The coolant-to-mainstream density ratios for both the blade and trailing edge coolant ejection range from 1.5 to 2.0 for simulating realistic engine conditions. Blade blowing ratio studies are 0.5 and 1.0 on the suction surface and 1.0 and 2.0 on the pressure surface. The trailing edge jet blowing ratio and Strouhal numbers are 1.0 and 0.12, respectively. The results show that the unsteady wake reduces the overall film cooling effectiveness. However, the unsteady wake with trailing edge coolant ejection enhances the overall effectiveness. The results also show that the overall filming cooling effectiveness increases by using heavier coolant for trailing edge ejection and for blade surface film cooling.

Author(s):  
Shiou-Jiuan Li ◽  
Akhilesh P. Rallabandi ◽  
Je-Chin Han

Detailed film cooling effectiveness distributions along a modeled turbine rotor blade under combined effects of upstream trailing edge unsteady wake with coolant ejection are presented using the pressure sensitive paint (PSP) mass transfer analogy method. The experiment is conducted in a low speed wind tunnel facility with a five blade linear cascade. The exit Reynolds number based on the axial chord is 370,000. Unsteady wakes and trailing edge coolant jets are produced by a spoked wheel-type wake generator with hollow rods equipped with several coolant ejections from holes. The coolant-to-mainstream density ratios for both blade and trailing edge coolant ejection range from 1.5 to 2.0 for simulating realistic engine conditions. Blade blowing ratios studied are 0.5 and 1.0 on Suction surface and 1.0 and 2.0 on Pressure surface. Trailing edge jet blowing ratio and Strouhal number are 1.0 and 0.12, respectively. Results show the unsteady wake reduces overall film cooling effectiveness. However, the unsteady wake with trailing edge coolant ejection enhances overall effectiveness. Results also show that the overall filming cooling effectiveness increases by using heavier coolant for trailing edge ejection as well as for blade surface film cooling.


Author(s):  
Kenichiro Takeishi ◽  
Sunao Aoki ◽  
Tomohiko Sato ◽  
Keizo Tsukagoshi

The film cooling effectiveness on a low-speed stationary cascade and the rotating blade has been measured by using a heat-mass transfer analogy. The film cooling effectiveness on the suction surface of the rotating blade fits well with that on the stationary blade, but a low level of effectiveness appears on the pressure surface of the rotating blade. In this paper, typical film cooling data will be presented and film cooling on a rotating blade is discussed.


1992 ◽  
Vol 114 (4) ◽  
pp. 828-834 ◽  
Author(s):  
K. Takeishi ◽  
S. Aoki ◽  
T. Sato ◽  
K. Tsukagoshi

The film cooling effectiveness on a low-speed stationary cascade and the rotating blade has been measured by using a heat-mass transfer analogy. The film cooling effectiveness on the suction surface of the rotating blade fits well with that on the stationary blade, but a low level of effectiveness appears on the pressure surface of the rotating blade. In this paper, typical film cooling data will be presented and film cooling on a rotating blade is discussed.


2009 ◽  
Vol 132 (1) ◽  
Author(s):  
N. J. Fiala ◽  
I. Jaswal ◽  
F. E. Ames

Heat transfer and film cooling distributions have been acquired for a vane trailing edge with letterbox partitions. Additionally, pressure drop data have been experimentally determined across a pin fin array and a trailing edge slot with letterbox partitions. The pressure drop across the array and letterbox trailing edge arrangement was measurably higher than for the gill slot geometry. Experimental data for the partitions and the inner suction surface region downstream from the slot have been acquired over a four-to-one range in vane exit condition Reynolds number (500,000, 1,000,000, and 2,000,000), with low (0.7%), grid (8.5%), and aerocombustor (13.5%) turbulence conditions. At these conditions, both heat transfer and adiabatic film cooling distributions have been documented over a range of blowing ratios (0.47≤M≤1.9). Heat transfer distributions on the inner suction surface downstream from the slot ejection were found to be dependent on both ejection flow rate and external conditions. Heat transfer on the partition side surfaces correlated with both exit Reynolds number and blowing ratio. Heat transfer on partition top surfaces largely correlated with exit Reynolds number but blowing ratio had a small effect at higher values. Generally, adiabatic film cooling levels on the inner suction surface are high but decrease near the trailing edge and provide some protection for the trailing edge. Adiabatic effectiveness levels on the partitions correlate with blowing ratio. On the partition sides adiabatic effectiveness is highest at low blowing ratios and decreases with increasing flow rate. On the partition tops adiabatic effectiveness increases with increasing blowing ratio but never exceeds the level on the sides. The present paper, together with a companion paper that documents letterbox trailing edge aerodynamics, is intended to provide engineers with the heat transfer and aerodynamic loss information needed to develop and compare competing trailing edge designs.


Author(s):  
Akhilesh P. Rallabandi ◽  
Shiou-Jiuan Li ◽  
Je-Chin Han

The effect of an unsteady stator wake (simulated by wake rods mounted on a spoke wheel wake generator) on the modeled rotor blade is studied using the Pressure Sensitive Paint (PSP) mass transfer analogy method. Emphasis of the current study is on the mid-span region of the blade. The flow is in the low Mach number (incompressible) regime. The suction (convex) side has simple angled cylindrical film-cooling holes; the pressure (concave) side has compound angled cylindrical film cooling holes. The blade also has radial shower-head leading edge film cooling holes. Strouhal numbers studied range from 0 to 0.36; the exit Reynolds Number based on the axial chord is 530,000. Blowing ratios range from 0.5 to 2.0 on the suction side; 0.5 to 4.0 on the pressure side. Density ratios studied range from 1.0 to 2.5, to simulate actual engine conditions. The convex suction surface experiences film-cooling jet lift-off at higher blowing ratios, resulting in low effectiveness values. The film coolant is found to reattach downstream on the concave pressure surface, increasing effectiveness at higher blowing ratios. Results show deterioration in film cooling effectiveness due to increased local turbulence caused by the unsteady wake, especially on the suction side. Results also show a monotonic increase in film-cooling effectiveness on increasing the coolant to mainstream density ratio.


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Akhilesh P. Rallabandi ◽  
Shiou-Jiuan Li ◽  
Je-Chin Han

The effect of an unsteady stator wake (simulated by wake rods mounted on a spoke-wheel wake generator) on the modeled rotor blade is studied using the pressure sensitive paint (PSP) mass-transfer analogy method. Emphasis of the current study is on the midspan region of the blade. The flow is in the low Mach number (incompressible) regime. The suction (convex) side has simple angled cylindrical film-cooling holes; the pressure (concave) side has compound angled cylindrical film-cooling holes. The blade also has radial shower-head leading edge film-cooling holes. Strouhal numbers studied range from 0 to 0.36; the exit Reynolds number based on the axial chord is 530,000. Blowing ratios range from 0.5 to 2.0 on the suction side and 0.5 to 4.0 on the pressure side. Density ratios studied range from 1.0 to 2.5, to simulate actual engine conditions. The convex suction surface experiences film-cooling jet lift-off at higher blowing ratios, resulting in low effectiveness values. The film coolant is found to reattach downstream on the concave pressure surface, increasing effectiveness at higher blowing ratios. Results show deterioration in film-cooling effectiveness due to increased local turbulence caused by the unsteady wake, especially on the suction side. Results also show a monotonic increase in film-cooling effectiveness on increasing the coolant to mainstream density ratio.


Author(s):  
Lesley M. Wright ◽  
Evan L. Martin

Detailed film cooling effectiveness distributions are obtained on a flat plate using the pressure sensitive paint (PSP) technique. The effects of average blowing ratio (M = 0.25–1.0) and coolant – to – mainstream density ratio (DR = 1.0–1.4) are evaluated in a low speed wind tunnel with a freestream velocity of 8.5 m/s and a freestream turbulence intensity of 6.8%. The coolant – to – mainstream density ratio is varied by using either nitrogen (DR = 1.0) or argon (DR = 1.4) as the coolant gases. The double hole geometry consists of a row of simple angle (θ = 35°), cylindrical holes coupled with one row of compound angle holes (θ = 45°, β = 50°). With the selected geometry, the compound holes effectively weaken the counter rotating vortex pair formed within the traditional simple angle hole. Therefore, the surface film cooling effectiveness is increased compared to a single row of simple angle film cooling holes. While increasing the blowing ratio decreases the film cooling effectiveness, the severity of the film cooling effectiveness reduction is less than with the single row of holes.


Author(s):  
Yang Zhang ◽  
Xin Yuan

The film cooling ejection on High Pressure (Hp) turbine component surface is strongly affected by the complex flow structure in the nozzle guide vane or rotor blade passages. The action of secondary flow in the main passage could dominate the film cooling effectiveness distribution on the component surfaces. The film cooling ejections from endwall and airfoil trailing edge are mixed by the secondary flow. Considering a small part of the coolant ejection from trailing edge discharge flow will move from the airfoil trailing edge pressure side to endwall downstream and then cover some area, the interaction between the coolants injected from endwall and airfoil trailing edge is worth investigating. Though the temperature of coolant discharge flow from trailing edge increases after the mixing process in the internal cooling procedure, the ejections moving from airfoil to endwall still have the potential of second order cooling. This part of the coolant is called “Phantom cooling flow” in the paper. A typical scale-up model of Hp turbine NGV is used in the experiment to investigate the cooling performance of ejection from trailing edge. Instead of the airfoil trailing edge platform itself, the film cooling effectiveness is measured on the downstream part of the endwall. This paper is focused on the trailing edge discharge flow with compound angle effects and the coolant from discharge holes moving from trailing edge to endwall surface. The coolant flow is injected from the straight discharge holes with a compound angle of 15deg and 45deg respectively. The film cooling holes on the endwall are used simultaneously to investigate the combined effects. The blowing ratio and different configurations of compound angle holes are selected to be the changing parameters in the paper. The experiment is completed with the blowing ratio changing from M = 0.7 to M = 1.3 and the compound angle is introduced to the entire row of trailing edge discharge holes (full span), with inlet Reynolds numbers of Re = 3.5×105 and an inlet Mach number of Ma = 0.1.


Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Qi-jiao He ◽  
Gang Xie

The trailing edge of the high-pressure turbine blade presents significant challenges to cooling structure design. To achieve better cooling performance at turbine blade trailing edge, a novel ribbed cutback structure is proposed for trailing edge cooling, which has rib structures on the cutback surface for heat transfer enhancement. In this study, numerical simulations have been performed on the effects of V-shaped rib angle on the film cooling characteristics and flow physics. Three V-shaped rib angles of 30°, 45° and 60° are studied. The distributions of adiabatic cooling effectiveness and heat transfer coefficient are obtained under blowing ratios with the value of 0.5, 1.0 and 1.5 respectively. Due to the relatively small rib height, the effect of V-shaped ribs on the film cooling effectiveness is not notable. The disadvantage of V-shaped ribs mainly exhibits at the downstream area of cutback surface. With the increase of V-shaped rib angle, the film cooling effectiveness becomes lower, but the values are still above 0.9. The V-shaped ribs obviously enhance the heat transfer on trailing edge cutback surface. The area-averaged heat transfer coefficient of the V-rib case is higher than that of the smooth case by 26.3–41.2%. The 45° V-rib case has higher heat transfer intensity than the other two V-shaped rib cases under all the three blowing ratios. However, the heat transfer coefficient distribution of the 60° V-rib case is more uniform. The heat transfer intensity of the 30° V-rib case is higher in the downstream region than the other two cases, but lower in the upstream region in which the difference becomes smaller with the increase of blowing ratio. The 45° V-rib case and the 60° V-rib case both reach the maximum value of area-averaged heat transfer intensity under blowing ratio is 1.0. Under higher blowing ratio, the 30° V-rib case and the 45° V-rib case outperform 2.1% and 6.7% higher value relative to the 60° V-rib case respectively due to the smaller velocity gradient in the 60° V-rib case in the downstream.


2014 ◽  
Vol 695 ◽  
pp. 376-379 ◽  
Author(s):  
Kianpour Ehsan ◽  
Nor Azwadi Che Sidik

The current study was conducted to analyze the effects of cylindrical and row trenched cooling holes with alignment angle of 90 degrees at blowing ratio, BR = 1.25 on the film cooling effectiveness near the end wall surface of a combustor simulator. In the current research a three dimensional representation of Pratt and Whitney gas turbine engine was simulated and analyzed with a commercial finite volume package FLUENT 6.2.26. This study has been performed with Reynolds-averaged Navier-Stokes turbulence model (RANS) on internal cooling passages. This combustor simulator combined the interaction of two rows of dilution jets, which were staggered in the stream wise direction and aligned in the span wise arrangement, with that of film cooling along the combustor liner walls. The findings of the study declared that with using the row trenched holes near the end wall surface, film cooling effectiveness is increased three times compared to the cooling performance of baseline case.