Computational Analysis of Conjugate Heat Transfer and Particulate Deposition on a High Pressure Turbine Vane

2011 ◽  
Vol 134 (4) ◽  
Author(s):  
Weiguo Ai ◽  
Thomas H. Fletcher

Numerical computations were conducted to simulate flash deposition experiments on gas turbine disk samples with internal impingement and film cooling using a computational fluid dynamics (CFD) code (FLUENT). The standard k-ω turbulence model and Reynolds-averaged Navier–Stokes were employed to compute the flow field and heat transfer. The boundary conditions were specified to be in agreement with the conditions measured in experiments performed in the BYU turbine accelerated deposition facility (TADF). A Lagrangian particle method was utilized to predict the ash particulate deposition. User-defined subroutines were linked with FLUENT to build the deposition model. The model includes particle sticking/rebounding and particle detachment, which are applied to the interaction of particles with the impinged wall surface to describe the particle behavior. Conjugate heat transfer calculations were performed to determine the temperature distribution and heat transfer coefficient in the region close to the film cooling hole and in the regions further downstream of a row of film cooling holes. Computational and experimental results were compared to understand the effect of film hole spacing, hole size, and TBC on surface heat transfer. Calculated capture efficiencies compare well with experimental results.

Author(s):  
Weiguo Ai ◽  
Thomas H. Fletcher

Numerical computations were conducted to simulate flyash deposition experiments on gas turbine disk samples with internal impingement and film cooling using a CFD code (FLUENT). The standard k-ω turbulence model and RANS were employed to compute the flow field and heat transfer. The boundary conditions were specified to be in agreement with the conditions measured in experiments performed in the BYU Turbine Accelerated Deposition Facility (TADF). A Lagrangian particle method was utilized to predict the ash particulate deposition. User-defined subroutines were linked with FLUENT to build the deposition model. The model includes particle sticking/rebounding and particle detachment, which are applied to the interaction of particles with the impinged wall surface to describe the particle behavior. Conjugate heat transfer calculations were performed to determine the temperature distribution and heat transfer coefficient in the region close to the film-cooling hole and in the regions further downstream of a row of film-cooling holes. Computational and experimental results were compared to understand the effect of film hole spacing, hole size and TBC on surface heat transfer. Calculated capture efficiencies compare well with experimental results.


2021 ◽  
pp. 1-20
Author(s):  
Hongyan Bu ◽  
Yufeng Yang ◽  
Liming Song ◽  
Jun Li

Abstract The gas turbine endwall is bearing extreme thermal loads with the rapid increase of turbine inlet temperature. Therefore, the effective cooling of turbine endwalls is of vital importance for the safe operation of turbines. In the design of endwall cooling layouts, numerical simulations based on conjugate heat transfer (CHT) are drawing more attention as the component temperature can be predicted directly. However, the computation cost of high-fidelity CHT analysis can be high and even prohibitive especially when there are many cases to evaluate such as in the design optimization of cooling layout. In this study, we established a multi-fidelity framework in which the data of low-fidelity CHT analysis was incorporated to help the building of a model that predicts the result of high-fidelity simulation. Based upon this framework, multi-fidelity design optimization of a validated numerical turbine endwall model was carried out. The high and low fidelity data were obtained from the computation of fine mesh and coarse mesh respectively. In the optimization, the positions of the film cooling holes were parameterized and controlled by a shape function. With the help of multi-fidelity modeling and sequentially evaluated designs, the cooling performance of the model endwall was improved efficiently.


Author(s):  
Vijay K. Garg

A multi-block, three-dimensional Navier-Stokes code has been used to compute heat transfer coefficient on the blade, hub and shroud for a rotating high-pressure turbine blade with 172 film-cooling holes in eight rows. Film cooling effectiveness is also computed on the adiabatic blade. Wilcox’s k-ω model is used for modeling the turbulence. Of the eight rows of holes, three are staggered on the shower-head with compound-angled holes. With so many holes on the blade it was somewhat of a challenge to get a good quality grid on and around the blade and in the tip clearance region. The final multi-block grid consists of 4784 elementary blocks which were merged into 276 super blocks. The viscous grid has over 2.2 million cells. Each hole exit, in its true oval shape, has 80 cells within it so that coolant velocity, temperature, k and ω distributions can be specified at these hole exits. It is found that for the given parameters, heat transfer coefficient on the cooled, isothermal blade is highest in the leading edge region and in the tip region. Also, the effectiveness over the cooled, adiabatic blade is the lowest in these regions. Results for an uncooled blade are also shown, providing a direct comparison with those for the cooled blade. Also, the heat transfer coefficient is much higher on the shroud as compared to that on the hub for both the cooled and the uncooled cases.


2021 ◽  
Author(s):  
Hongyan Bu ◽  
Yufeng Yang ◽  
Liming Song ◽  
Jun Li

Abstract The gas turbine endwall is bearing extreme thermal loads with the rapid increase of turbine inlet temperature. Therefore, the effective cooling of turbine endwalls is of vital importance for the safe operation of turbines. In the design of endwall cooling layouts, numerical simulations based on conjugate heat transfer (CHT) are drawing more attention as the component temperature can be predicted directly. However, the computation cost of high-fidelity CHT analysis can be high and even prohibitive especially when there are many cases to evaluate such as in the design optimization of cooling layout. In this study, we established a multi-fidelity framework in which the data of low-fidelity CHT analysis was incorporated to help the building of a model that predicts the result of high-fidelity simulation. Based upon this framework, multi-fidelity design optimization of a validated numerical turbine endwall model was carried out. The high and low fidelity data were obtained from the computation of fine mesh and coarse mesh respectively. In the optimization, the positions of the film cooling holes were parameterized and controlled by a shape function. With the help of multi-fidelity modeling and sequentially evaluated designs, the cooling performance of the model endwall was improved efficiently.


Author(s):  
Adamos Adamou ◽  
Colin Copeland

Abstract Augmented backside cooling refers to the enhancement of the backside convection of a combustor liner using extended heat transfer surfaces to fully utilise the cooling air by maximising the heat transfer to pumping ratio characteristic. Although film cooling has and still is widely used in the gas turbine industry, augmented backside cooling has been in development for decades now. The reason for this, is to reduce the amount of air used for liner cooling and to also reduce the emissions caused by using film cooling in the primary zones. In the case of micro gas turbines, emissions are of even greater importance, since the regulations for such engines will most likely become stricter in the following years due to a global effort to reduce emission. Furthermore, the liners investigated in this paper are for a 10 kWe micro turbine, destine for various potential markets, such as combine heat and power for houses, EV hybrids and even small UAVs. The majority of these markets require long service intervals, which in turn requires the combustor liners to be under the least amount of thermal stress possible. The desire to also increase combustor inlet temperatures with the use of recuperated exhaust gases, which in turn increase the overall system efficiency, limits the cooling effectiveness of the inlet air. Due to all these reasons, an advanced form of augmented backside cooling would be of substantial significance in such a system. Currently some very simple designs are used in the form of straight plain fins, transverse strips or other similar geometries, but the creation of high heat transfer efficiency surfaces in such small sizes becomes very difficult with traditional subtractive manufacturing methods. When using additive manufacturing though these types of surfaces are not an issue. This paper covers the comparison of experimental results with conjugate heat transfer CFD models and empirical heat balance models for two different AM liner cooling geometries and an AM blank liner. The two cooling fin geometries include a rotating plain fin and an offset strip fin. The liners were tested in an AM built reverse flow radial swirl stabilised combustion chamber at a variety of operating conditions. During the experiments the surfaces were compared using a thermal camera to record the outer liner temperature which was viewed through a quartz outer casing. The experimental results showed that the cooling surfaces were effective at reducing the liner temperatures with minimal pressure losses for multiple operating points. Those results were then compared against the conjugate heat transfer CFD models and the empirical calculations used to design the surfaces initially. From this comparison, it was noticed both the CFD and empirical calculations under predicted the wall temperatures. This is thought to be due to inaccuracies in the predicted flame temperatures and the assumed emissivity values used to calibrate the thermal imaging camera. Further uncertainties arise from the assumption of a constant air and hot gas temperature and mass flow along the cooling surfaces and the lack of data for the surface roughness of the parts.


2008 ◽  
Vol 130 (3) ◽  
Author(s):  
James D. Heidmann ◽  
Srinath Ekkad

A novel turbine film-cooling hole shape has been conceived and designed at NASA Glenn Research Center. This “antivortex” design is unique in that it requires only easily machinable round holes, unlike shaped film-cooling holes and other advanced concepts. The hole design is intended to counteract the detrimental vorticity associated with standard circular cross-section film-cooling holes. This vorticity typically entrains hot freestream gas and is associated with jet separation from the turbine blade surface. The antivortex film-cooling hole concept has been modeled computationally for a single row of 30 deg angled holes on a flat surface using the 3D Navier–Stokes solver GLENN-HT. A blowing ratio of 1.0 and density ratios of 1.05 and 2.0 are studied. Both film effectiveness and heat transfer coefficient values are computed and compared to standard round hole cases for the same blowing rates. A net heat flux reduction is also determined using both the film effectiveness and heat transfer coefficient values to ascertain the overall effectiveness of the concept. An improvement in film effectiveness of about 0.2 and in net heat flux reduction of about 0.2 is demonstrated for the antivortex concept compared to the standard round hole for both blowing ratios. Detailed flow visualization shows that as expected, the design counteracts the detrimental vorticity of the round hole flow, allowing it to remain attached to the surface.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Marc Fraas ◽  
Tobias Glasenapp ◽  
Achmed Schulz ◽  
Hans-Jörg Bauer

Internal coolant passages of gas turbine vanes and blades have various orientations relative to the external hot gas flow. As a consequence, the inflow of film cooling holes varies as well. To further identify the influencing parameters of film cooling under varying inflow conditions, the present paper provides detailed experimental data. The generic study is performed in a novel test rig, which enables compliance with all relevant similarity parameters including density ratio. Film cooling effectiveness as well as heat transfer of a 10–10–10 deg laidback fan-shaped cooling hole is discussed. Data are processed and presented over 50 hole diameters downstream of the cooling hole exit. First, the parallel coolant flow setup is discussed. Subsequently, it is compared to a perpendicular coolant flow setup at a moderate coolant channel Reynolds number. For the perpendicular coolant flow, asymmetric flow separation in the diffuser occurs and leads to a reduction of film cooling effectiveness. For a higher coolant channel Reynolds number and perpendicular coolant flow, asymmetry increases and cooling effectiveness is further decreased. An increase in blowing ratio does not lead to a significant increase in cooling effectiveness. For all cases investigated, heat transfer augmentation due to film cooling is observed. Heat transfer is highest in the near-hole region and decreases further downstream. Results prove that coolant flow orientation has a severe impact on both parameters.


Author(s):  
T. I-P. Shih ◽  
Y.-L. Lin ◽  
M. K. Chyu ◽  
S. Gogineni

Computations were performed to study the three-dimensional flow and heat transfer on a flat plate cooled by jets, injected from a plenum through one row of film-cooling holes in which each hole is fitted with a strut in the form of a circular cylinder. Three different configurations of the film-cooling hole were investigated: without strut, with streamwise strut, and with spanwise strut. For all configurations, the film-cooling holes are inclined at 35°, and the coolant-to-mainflow density and mass-flux ratios are 1.6 and 0.5, respectively. The focus of this study is to understand how struts in holes affect film cooling jets and their interactions with the mainflow in forming a protective layer of cooler fluid over the plate. This computational study is based on the ensemble-averaged conservation equations of mass, momentum (compressible Navier-Stokes), and energy. Effects of turbulence was modeled by a low Reynolds number k-ω closure known as the shear-stress-transport (SST) model. Solutions were generated by a cell-centered finite-volume method that uses third-order accurate flux-difference splitting of Roe with limiters, multigrid acceleration of a diagonalized ADI scheme with local time stepping, and patched/overlapped structured grids. In the computations, the flow is resolved not just in the cooling-jet/mainflow interaction region, but also inside the film-cooling holes and in the plenum. Computed results for adiabatic effectiveness for the case without struts were compared with experimental data, and reasonably good agreements were obtained.


Author(s):  
Cuong Q. Nguyen ◽  
Perry L. Johnson ◽  
Bryan C. Bernier ◽  
Son H. Ho ◽  
Jayanta S. Kapat

Data from conical-shaped film cooling holes is extremely sparse in open literature, especially the cooling uniformity characteristic, an important criterion for evaluating any film cooling design. The authors will compare the performance of conical-shaped holes to cylindrical-shaped holes. Cylindrical-shaped holes are often considered a baseline in terms of film cooling effectiveness and cooling uniformity coefficient. The authors will study two coupons with conical-shaped holes, which have 3° and 6° diffusion angles, named CON3 and CON6 respectively. A conjugate heat transfer computational fluid dynamics model and an experimental wind tunnel will be used to study these coupons. The three configurations: cylindrical baseline, CON3, and CON6, have a single row of holes with an inlet metering diameter of 3mm, length-to-nominal diameter of 4.3, and an injection angle of 30°. In this study, the authors will also take into account the heat transfer into the coolant flow from the coolant channel. In other words, coolant temperature at the exit of the coolant hole will be different than that measured at the inlet, and the conjugate heat transfer model will be used to correct for this difference. For the numerical model, the realizable k-ε turbulent model will be applied with a second order of discretization and enhanced wall treatment to provide the highest accuracy available. Grid independent studies for both cylindrical-shaped film cooling holes and conical-shaped holes will be performed and the results will be compared to data in open literature as well as in-house experimental data. Results show that conical-shaped holes considerably outperform cylindrical-shaped holes in film cooling effectiveness at all blowing ratios. In terms of cooling uniformity, conical-shaped holes perform better than cylindrical-shaped holes for low and mid-range blowing ratios, but not at higher levels.


Sign in / Sign up

Export Citation Format

Share Document