Thermal Hydraulic Study of a Single Row Heat Exchanger With Helically Finned Tubes

2010 ◽  
Vol 132 (6) ◽  
Author(s):  
H. Huisseune ◽  
C. T’Joen ◽  
P. Brodeoux ◽  
S. Debaets ◽  
M. De Paepe

In this study, the heat transfer and friction correlation of a single row heat exchanger with helically finned tubes are experimentally determined. The transversal tube pitch was parametrically varied. A detailed description of the test rig and the data reduction procedure is given. A thorough uncertainty analysis was performed to validate the results. The proposed heat transfer correlation can describe 95% of the data within ±11% and shows a 4.49% mean deviation. The friction correlation predicts 95% of the data within ±19% with a mean deviation of 6.84%. The new correlations show the same trend as most correlations from open literature, but none of the literature correlations are able to accurately predict the results of this study.

1999 ◽  
Vol 121 (3) ◽  
pp. 662-667 ◽  
Author(s):  
N. H. Kim ◽  
B. Youn ◽  
R. L. Webb

This paper deals with heat exchangers having plain fins on a staggered array of circular tubes. Correlations are developed to predict the air-side heat transfer coefficient and friction factor as a function of the Reynolds number and geometric variables of the heat exchanger such as tube diameter, tube pitch, fin spacing, etc. A multiple regression technique was used to correlate 47 sets of heat exchanger data to develop the heat transfer and friction correlation. The correlations are applicable to heat exchangers having small diameter tubes (or large tube pitch to tube diameter ratio), whose performance previous correlations failed to predict adequately. The heat transfer correlation applicable to three or more row configuration predicts 94 percent of the data within ±20 percent, and the heat transfer correlation applicable to one- or two-row configuration predicts 94 percent of the data within ±20 percent. The friction correlation predicts 90 percent of the data within ±20 percent.


1988 ◽  
Vol 110 (1) ◽  
pp. 60-67 ◽  
Author(s):  
H. Halle ◽  
J. M. Chenoweth ◽  
M. W. Wambsganss

Throughout the life of a heat exchanger, a significant part of the operating cost arises from pumping the heat transfer fluids through and past the tubes. The pumping power requirement is continuous and depends directly upon the magnitude of the pressure losses. Thus, in order to select an optimum heat exchanger design, it is is as important to be able to predict pressure drop accurately as it is to predict heat transfer. This paper presents experimental measurements of the shellside pressure drop for 24 different segmentally baffled bundle configurations in a 0.6-m (24-in.) diameter by 3.7-m (12-ft) long shell with single inlet and outlet nozzles. Both plain and finned tubes, nominally 19-mm (0.75-in.) outside diameter, were arranged on equilateral triangular, square, rotated triangular, and rotated square tube layouts with a tube pitch-to-diameter ratio of 1.25. Isothermal water tests for a range of Reynolds numbers from 7000 to 100,000 were run to measure overall as well as incremental pressure drops across sections of the exchanger. The experimental results are given and correlated with a pressure drop versus flowrate relationship.


Author(s):  
Joshua D. Sole ◽  
Bradley J. Shelofsky ◽  
Robert P. Scaringe ◽  
Gregory S. Cole

Electronics of all types, particularly those in the military aviation arena, are decreasing in size while at the same time increasing in power. As a result, newer high-heat-flux electronic components are exceeding the cooling capabilities of conventional single-phase military aviation coldplates and coolants. It is for this reason that we have been investigating new methods to cool the next generation of high-heat-flux military aviation electronics. In this work, a novel method of inducing two-phase conditions within a microchannel heat exchanger has been developed and demonstrated. Micro-orifices placed upstream of each microchannel in a microchannel heat exchanger not only cause an improvement in flow distribution, but can also induce cavitation in the incoming subcooled refrigerant and result in favorable two-phase flow regimes for enhanced heat transfer. In this study, R-134a is used as the coolant in the cavitation enhanced microchannel heat exchanger (CEMC-HX) which has been integrated into a vapor compression refrigeration system. Multiple micro-orifice geometries combined with a fixed microchannel geometry (nominally 250 μm × 250 μm) were investigated over a range of applied base heat fluxes (10–100 W/cm2) and mass fluxes (500–1000 kg/m2-s). Two-phase heat transfer coefficients exceeding 100,000 W/m2-K at refrigerant qualities of less than 5% have been demonstrated due to the achievement of preferential, cavitation-induced, flow regimes such as annular flow. To the author’s knowledge, this is the highest heat transfer coefficient ever reported in the literature for R-134a. Additionally, a four term two-phase heat transfer correlation was developed that achieved a mean absolute error (MAE) of 25.5%.


Author(s):  
M. M. Kabir ◽  
Sangsoo Lee

Abstract Recent leaps in heat dissipation make it difficult for typical heat exchangers to meet the requirements of the advanced applications even with the maximally obtainable heat transfer performance associated with a single-phase process. Especially high heat flux applications such as thermal management in microelectronics, advanced material processing, and nuclear fusion reactors require extreme heat transfer methods to overcome the current limits. In this study, a heat exchanger adopting simultaneously two-opposite, phase-change heat transfer processes (internal flow boiling and external condensation) was proposed and analytically investigated. The phase-change heat transfer analyses were conducted for internal flow boiling and external condensation at a test section and the heat transfer performances were compared with that of a system with an internal single-phase, liquid flow process. It is found that the proposed heat exchanger configuration with an internal flow boiling can substantially enhance the heat transfer performances and provide better methods to manage the temperature difference comparing to those with an internal single-phase heat transfer due to its significant increase in a heat transfer coefficients and constant temperatures during phase-change processes. Additionally, this study also explains the design for a test rig to evaluate and validate the results in detail. The test rig consists of an internal flow boiling loop with a test section, an external condensation loop, sensors, auxiliary monitoring parts, and controlling and data acquisition systems. Thermodynamic cycle, pressure drop, and heat transfer analyses were conducted to determine the conditions and the specifications of components and sensors for the test rig.


2015 ◽  
Vol 23 (01) ◽  
pp. 1550007 ◽  
Author(s):  
Ryoji Katsuki ◽  
Tsutomu Shioyama ◽  
Chikako Iwaki ◽  
Tadamichi Yanazawa

We have been developing a free convection air cooled heat exchanger without power supply to improve economic efficiency and mechanical reliability. However, this heat exchanger requires a larger installation area than the forced draft type air cooled heat exchanger since a large heating surface is needed to compensate for the small heat transfer by natural convection. Therefore, we have been investigating a heat exchanger consisting of an array of finned tubes and chimney to increase the heat transfer coefficient. Since the heat transfer characteristics of finned tube arrays have not been clarified, we conducted experiments with a finned tube array to determine the relation between the configuration of finned tubes and the heat transfer coefficient of a tube array. The results showed that the average heat transfer coefficient increased with pitch in the vertical direction, and became constant when the pitch was over five times the fin diameter. The average heat transfer coefficient was about 1.4 times higher than that of a single finned tube in free space. The ratio of the average heat transfer coefficient of the finned tube array with chimney to that of a single finned tube was found to be independent of the difference in temperature between the tube surface and air.