Analysis of Two-Dimensional Motion Resisted by Coulomb Friction

1963 ◽  
Vol 85 (1) ◽  
pp. 17-26 ◽  
Author(s):  
T. P. Goodman

The effect of Coulomb (dry) friction between surfaces of adjacent machine members, either in preventing relative sliding motion or in absorbing energy when relative motion does occur, has traditionally been analyzed on a one-dimensional basis. The two-dimensional analysis presented in this paper shows how the effectiveness of Coulomb friction in preventing relative sliding motion is greatly reduced by eccentric loading, and how the effectiveness of Coulomb friction in absorbing the energy of an oscillation may be greatly reduced by the addition of a second oscillatory or unidirectional motion. The results of the analysis are correlated with experimental data.

2013 ◽  
Vol 33 (2) ◽  
pp. 249-257 ◽  
Author(s):  
Alberto Colombo ◽  
Lívia A. Alvarenga ◽  
Myriane S. Scalco ◽  
Randal C. Ribeiro ◽  
Giselle F. Abreu

The increasing demand for water resources accentuates the need to reduce water waste through a more appropriate irrigation management. In the particular case of irrigated coffee planting, which in recent years presented growth with the predominance of drip irrigation, the improvement of drip irrigation management techniques is a necessity. The proper management of drip irrigation depends on the knowledge of the spatial pattern of soil moisture distribution inside the wetted strip formed under the irrigation lines. In this study, grids of 24 tensiometers were used to determine the water storage within the wetted strip formed under drippers, with a 3.78 L h-1 discharge, evenly spaced by 0.4 m, subjected to two different management criteria (fixed irrigation interval and 60 kPa tension). Estimates of storage based on a one-dimensional analysis, that only considers depth variations, were compared with two-dimensional estimates. The results indicate that for high-frequency irrigation the one-dimensional analysis is not appropriate. However, under less frequent irrigation, the two-dimensional analysis is dispensable, being the one-dimensional sufficient for calculating the water volume stored in the wetted strip.


Water SA ◽  
2019 ◽  
Vol 45 (3 July) ◽  
Author(s):  
Ahmed M Helmi

Floodways, where a road embankment is permitted to be overtopped by flood water, are usually designed as broad-crested weirs. Determination of the water level above the floodway is crucial and related to road safety. Hydraulic performance of floodways can be assessed numerically using 1-D modelling or 3-D simulation using computational fluid dynamics (CFD) packages. Turbulence modelling is one of the key elements in CFD simulations. A wide variety of turbulence models are utilized in CFD packages; in order to identify the most relevant turbulence model for the case in question, 96 3-D CFD simulations were conducted using Flow-3D package, for 24 broad-crested weir configurations selected based on experimental data from a previous study. Four turbulence models (one-equation, k-ε, RNG k-ε, and k-ω) ere examined for each configuration. The volume of fluid (VOF) algorithm was adopted for free water surface determination. In addition, 24 1-D simulations using HEC-RAS-1-D were conducted for comparison with CFD results and experimental data. Validation of the simulated water free surface profiles versus the experimental measurements was carried out by the evaluation of the mean absolute error, the mean relative error percentage, and the root mean square error. It was concluded that the minimum error in simulating the full upstream to downstream free surface profile is achieved by using one-equation turbulence model with mixing length equal to 7% of the smallest domain dimension. Nevertheless, for the broad-crested weir upstream section, no significant difference in accuracy was found between all turbulence models and the one-dimensional analysis results, due to the low turbulence intensity at this part. For engineering design purposes, in which the water level is the main concern at the location of the flood way, the one-dimensional analysis has sufficient accuracy to determine the water level.


1999 ◽  
Vol 36 (02) ◽  
pp. 102-112
Author(s):  
Michael D. A. Mackney ◽  
Carl T. F. Ross

Computational studies of hull-superstructure interaction were carried out using one-, two-and three-dimensional finite element analyses. Simplification of the original three-dimensional cases to one- and two-dimensional ones was undertaken to reduce the data preparation and computer solution times in an extensive parametric study. Both the one- and two-dimensional models were evaluated from numerical and experimental studies of the three-dimensional arrangements of hull and superstructure. One-dimensional analysis used a simple beam finite element with appropriately changed sections properties at stations where superstructures existed. Two-dimensional analysis used a four node, first order quadrilateral, isoparametric plane elasticity finite element, with a corresponding increase in the grid domain where the superstructure existed. Changes in the thickness property reflected deck stiffness. This model was essentially a multi-flanged beam with the shear webs representing the hull and superstructure sides, and the flanges representing the decks One-dimensional models consistently and uniformly underestimated the three-dimensional behaviour, but were fast to create and run. Two-dimensional models were also consistent in their assessment, and considerably closer in predicting the actual behaviours. These models took longer to create than the one-dimensional, but ran in very much less time than the refined three-dimensional finite element models Parametric insights were accomplished quickly and effectively with the simplest model and processor, but two-dimensional analyses achieved closer absolute measure of the displacement behaviours. Although only static analysis with simple loading and support conditions were presented, it is believed that similar benefits would be found for other loadings and support conditions. Other engineering components and structures may benefit from similarly judged simplification using one- and two-dimensional models to reduce the time and cost of preliminary design.


2011 ◽  
Vol 21 (10) ◽  
pp. 3043-3046 ◽  
Author(s):  
SERGEY STEPANOV

A two-mass oscillator with one mass lying on the driving belt with dry Coulomb friction is considered. A numerical method for finding all limit cycles and their parametric investigation, based on the analysis of fixed points of a two-dimensional map, is suggested. As successive points for the map we chose points of friction transferred from stick mode to slip mode. These transfers are defined by two equalities and yield a two-dimensional map, in contrast to three-dimensional maps that we can construct for regularized continuous dry friction laws.


1976 ◽  
Vol 98 (3) ◽  
pp. 407-413 ◽  
Author(s):  
S. S. Dua ◽  
C. L. Tien

This paper presents a two-dimensional analysis of the effect of precursory cooling on conduction-controlled rewetting of a vertical surface, whose initial temperature is higher than the sputtering temperature. Precursory cooling refers to the cooling caused by the droplet-vapor mixture in the region immediately ahead of the wet front, and is described mathematically by two dimensionless constants which characterize its magnitude and the region of influence. The physical model developed to account for precursory cooling consists of an infinitely extended vertical surface with the dry region ahead of the wet front characterized by an exponentially decaying heat flux and the wet region behind the moving film-front associated with a constant heat transfer coefficient. Apart from the two dimensionless constants describing the extent of precursory cooling, the physical problem is characterized by three dimensionless groups: the Peclet number or the dimensionless wetting velocity, the Biot number and a dimensionless temperature. Limiting solutions for large and small Peclet numbers have been obtained utilizing the Wiener-Hopf technique coupled with appropriate kernel substitutions. A semiempirical matching relation is then devised for the entire range of Peclet numbers. Existing experimental data with variable flow rates at atmospheric pressure are very closely correlated by the present model. Finally a comparison is drawn between the one-dimensional limit of the present analysis and the corresponding one-dimensional solution obtained by treating the dry region ahead of the wet front characterized by an exponentially decaying heat transfer coefficient.


1967 ◽  
Vol 27 (1) ◽  
pp. 97-109 ◽  
Author(s):  
D. B. Spalding

A power-law relation is derived between the Stanton number and the Reynolds number, expressing the law of heat transfer for a wall adjacent to a region of turbulent separated flow. The derivation is based on Prandtl's (1945) proposal for the laws of dissipation, diffusion and generation of turbulent kinetic energy. The constants appearing in these laws are determined by reference to experimental data for the hydrodynamic properties of the constant-stress and the linear-stress layers.The agreement between the resulting predictions and the experimental data of other workers is sufficiently good to suggest that the actual mechanism of heat transfer from separated flows has much in common with that which is postulated. Closer agreement can be expected only after the present one-dimensional analysis has been superseded by a two-dimensional one.


Sign in / Sign up

Export Citation Format

Share Document