Two-Dimensional Analysis of Conduction-Controlled Rewetting With Precursory Cooling

1976 ◽  
Vol 98 (3) ◽  
pp. 407-413 ◽  
Author(s):  
S. S. Dua ◽  
C. L. Tien

This paper presents a two-dimensional analysis of the effect of precursory cooling on conduction-controlled rewetting of a vertical surface, whose initial temperature is higher than the sputtering temperature. Precursory cooling refers to the cooling caused by the droplet-vapor mixture in the region immediately ahead of the wet front, and is described mathematically by two dimensionless constants which characterize its magnitude and the region of influence. The physical model developed to account for precursory cooling consists of an infinitely extended vertical surface with the dry region ahead of the wet front characterized by an exponentially decaying heat flux and the wet region behind the moving film-front associated with a constant heat transfer coefficient. Apart from the two dimensionless constants describing the extent of precursory cooling, the physical problem is characterized by three dimensionless groups: the Peclet number or the dimensionless wetting velocity, the Biot number and a dimensionless temperature. Limiting solutions for large and small Peclet numbers have been obtained utilizing the Wiener-Hopf technique coupled with appropriate kernel substitutions. A semiempirical matching relation is then devised for the entire range of Peclet numbers. Existing experimental data with variable flow rates at atmospheric pressure are very closely correlated by the present model. Finally a comparison is drawn between the one-dimensional limit of the present analysis and the corresponding one-dimensional solution obtained by treating the dry region ahead of the wet front characterized by an exponentially decaying heat transfer coefficient.

1975 ◽  
Vol 97 (2) ◽  
pp. 161-165 ◽  
Author(s):  
C. L. Tien ◽  
L. S. Yao

The present paper presents a two-dimensional analysis of conduction-controlled rewetting of a vertical surface, whose initial temperature is greater than the rewetting temperature. The physical model consists of an infinitely extended vertical slab with the surface of the dry region adiabatic and the surface of the wet region associated with a constant heat transfer coefficient. The physical problem is characterized by three parameters: the Peclet number or the dimensionless wetting velocity, the Biot number, and a dimensionless temperature. Limiting solutions for large and small Peclet numbers obtained by utilizing the Wiener-Hopf technique and the kernel-substitution method exhibit simple functional relationships among the three dimensionless parameters. A semi- empirical relation has been established for the whole range of Peclet numbers. The solution for large Peclet numbers possesses a functional form different from existing approximate two-dimensional solutions, while the solution for small Peclet numbers reduces to existing one-dimensional solution for small Biot numbers. Discussion of the present findings has been made with respect to previous analyses and experimental observations.


2013 ◽  
Vol 33 (2) ◽  
pp. 249-257 ◽  
Author(s):  
Alberto Colombo ◽  
Lívia A. Alvarenga ◽  
Myriane S. Scalco ◽  
Randal C. Ribeiro ◽  
Giselle F. Abreu

The increasing demand for water resources accentuates the need to reduce water waste through a more appropriate irrigation management. In the particular case of irrigated coffee planting, which in recent years presented growth with the predominance of drip irrigation, the improvement of drip irrigation management techniques is a necessity. The proper management of drip irrigation depends on the knowledge of the spatial pattern of soil moisture distribution inside the wetted strip formed under the irrigation lines. In this study, grids of 24 tensiometers were used to determine the water storage within the wetted strip formed under drippers, with a 3.78 L h-1 discharge, evenly spaced by 0.4 m, subjected to two different management criteria (fixed irrigation interval and 60 kPa tension). Estimates of storage based on a one-dimensional analysis, that only considers depth variations, were compared with two-dimensional estimates. The results indicate that for high-frequency irrigation the one-dimensional analysis is not appropriate. However, under less frequent irrigation, the two-dimensional analysis is dispensable, being the one-dimensional sufficient for calculating the water volume stored in the wetted strip.


1999 ◽  
Vol 36 (02) ◽  
pp. 102-112
Author(s):  
Michael D. A. Mackney ◽  
Carl T. F. Ross

Computational studies of hull-superstructure interaction were carried out using one-, two-and three-dimensional finite element analyses. Simplification of the original three-dimensional cases to one- and two-dimensional ones was undertaken to reduce the data preparation and computer solution times in an extensive parametric study. Both the one- and two-dimensional models were evaluated from numerical and experimental studies of the three-dimensional arrangements of hull and superstructure. One-dimensional analysis used a simple beam finite element with appropriately changed sections properties at stations where superstructures existed. Two-dimensional analysis used a four node, first order quadrilateral, isoparametric plane elasticity finite element, with a corresponding increase in the grid domain where the superstructure existed. Changes in the thickness property reflected deck stiffness. This model was essentially a multi-flanged beam with the shear webs representing the hull and superstructure sides, and the flanges representing the decks One-dimensional models consistently and uniformly underestimated the three-dimensional behaviour, but were fast to create and run. Two-dimensional models were also consistent in their assessment, and considerably closer in predicting the actual behaviours. These models took longer to create than the one-dimensional, but ran in very much less time than the refined three-dimensional finite element models Parametric insights were accomplished quickly and effectively with the simplest model and processor, but two-dimensional analyses achieved closer absolute measure of the displacement behaviours. Although only static analysis with simple loading and support conditions were presented, it is believed that similar benefits would be found for other loadings and support conditions. Other engineering components and structures may benefit from similarly judged simplification using one- and two-dimensional models to reduce the time and cost of preliminary design.


2010 ◽  
Vol 29-32 ◽  
pp. 132-137 ◽  
Author(s):  
Xue Jiang Lai ◽  
Rui Li ◽  
Yong Dai ◽  
Su Yi Huang

Flower baffle heat exchanger’s structure and design idea is introduced. Flower baffle heat exchanger has unique support structure. It can both enhance the efficiency of the heat transfer and reduce the pressure drop. Through the experimental study, under the same shell side flow, the heat transfer coefficient K which the distance between two flower baffles is 134mm is higher 3%~9% than the one of which the distances between two flower baffles are 163mm,123mm. The heat transfer coefficient K which the distance between two flower baffles is 147mm is close to the one of which the distances between two flower baffles is 134mm. The shell volume flow V is higher, the incremental quantity of heat transfer coefficient K is more. The integrated performance K/Δp of flower baffle heat exchanger which the distance between two flower baffles is 134mm is higher 3%~9% than the one of which the distances between two flower baffles are 163mm,123mm. Therefore, the best distance between two flower baffles exists between 134mm~147mm this experiment.


Author(s):  
Alain J. Kassab ◽  
Eduardo A. Divo ◽  
Minking K. Chyu ◽  
Frank J. Cunha

The purpose of the inverse problem considered in this study is to resolve heat transfer coefficient distributions by solving a steady-state inverse problem. Temperature measurements at interior locations supply the additional information that renders the inverse problem solvable. A regularized quadratic functional is defined to measure the deviation of computed temperatures from the values under current estimates of the heat transfer coefficient distribution at the surface exposed to convective heat transfer. The inverse problem is solved by minimizing this functional using a parallelized genetic algorithm (PGA) as the minimization algorithm and a two-dimensional multi-region boundary element method (BEM) heat conduction code as the field variable solver. Results are presented for a regular rectangular geometry and an irregular geometry representative of a blade trailing edge and demonstrate the success of the approach in retrieving accurate heat transfer coefficient distributions.


Author(s):  
Fredrik Lundell ◽  
Bernard Thonon ◽  
Jean Antoine Gruss

Channel networks designed with constructal theory are compared. The efficiency of the networks when used for cooling a uniformly heated surface is compared. Three networks are compared and it is found that the two constructal designs with two and three constructal levels have similar performance. It is shown that for a given pumping power, the constructal designs give a heat transfer coefficient of the surface which is almost a factor of magnitude higher than the one obtained for a parallel channel system.


Author(s):  
Murali Krishnan R. ◽  
Zain Dweik ◽  
Deoras Prabhudharwadkar

This paper provides an extension of the previously described [1] formulation of a one-dimensional model for steady, compressible flow inside a channel, to the steam turbine application. The major challenge faced in the network simulation of the steam turbine secondary system is the prediction of the condensation that occurs during the engine start-up on the cold parts that are below the saturation temperature. Neglecting condensation effects may result in large errors in the engine temperatures since they are calculated based on the boundary conditions (heat transfer coefficient and bulk temperature) which depend on the solution of the network analysis. This paper provides a detailed formulation of a one-dimensional model for steady, compressible flow inside a channel which is based on the solution of two equations for a coupled system of mass, momentum and energy equations with wall condensation. The model also accounts for channel area variation, inclination with respect to the engine axis, rotation, wall friction and external heating. The formulation was first validated against existing 1D correlation for an idealized case. The wall condensation is modeled using the best-suited film condensation models for pressure and heat transfer coefficient available in the literature and has been validated against the experimental data with satisfactory predictions.


1974 ◽  
Vol 96 (4) ◽  
pp. 459-462 ◽  
Author(s):  
Terukazu Ota ◽  
Nobuhiko Kon

Heat transfer measurements are made in the separated, reattached, and redeveloped regions of the two-dimensional air flow on a flat plate with blunt leading edge. The flow reattachment occurs at about four plate thicknesses downstream from the leading edge and the heat transfer coefficient becomes maximum at that point and this is independent of the Reynolds number which ranged from 2720 to 17900 in this investigation. The heat transfer coefficient is found to increase sharply near the leading edge. The development of flow is shown through the measurements of the velocity and temperature in the separated, reattached, and redeveloped regions.


Sign in / Sign up

Export Citation Format

Share Document