The Correlation of Drop-Size Distributions in Fuel Nozzle Sprays—Part II: The Drop-Size/Number Distribution

1977 ◽  
Vol 99 (3) ◽  
pp. 315-319 ◽  
Author(s):  
H. C. Simmons

Using the data given in a companion paper by this author on drop-size/volume-fraction distributions in fuel nozzle sprays it is shown that drop-number distributions can be correlated on a nondimensional basis by cutting off data at the extreme tails of the volume distribution so that 99.74 percent of the spray is evaluated. Equations are developed for calculating both volume-fraction and number distributions given only the mass median or Sauter mean diameter for a spray. A theoretical model of the atomization process is proposed which is in good agreement with observed data. It is shown also that the accuracy of determining SMD is very little affected by lack of data at the ends of the drop-size range.

1977 ◽  
Vol 99 (3) ◽  
pp. 309-314 ◽  
Author(s):  
H. C. Simmons

The paper presents data on the drop-size/volume-fraction distributions of sprays observed with a large number of gas-turbine fuel nozzles of different types including both pressure and air-atomizers, using a range of fuel viscosities, at a variety of operating conditions. The data were obtained by both optical and wax-droplet methods. It is shown that a universal nondimensional correlation can be established for all the fuel nozzles when the drop-size is normalized to the mass median diameter. The correlation enables prediction of the drop-size/volume-fraction distribution for a spray given only the mass median or Sauter mean diameter.


2005 ◽  
Vol 44 (7) ◽  
pp. 1146-1151 ◽  
Author(s):  
Axel Seifert

Abstract The relation between the slope and shape parameters of the raindrop size distribution parameterized by a gamma distribution is examined. The comparison of results of a simple rain shaft model with an empirical relation based on disdrometer measurements at the surface shows very good agreement, but a more detailed discussion reveals some difficulties—for example, deviations from the gamma shape and the overestimation of collisional breakup.


2013 ◽  
Vol 446-447 ◽  
pp. 571-575 ◽  
Author(s):  
Chen Wei Liu ◽  
Ming Zhong Li

Systematic experimental study has been performed to examine the effects of dispersed phase viscosity on emulsification in turbulence flow. It is found that the volume drop size distributions widen as dispersed phase viscosity increased; at lower dispersed phase viscosity, both Sauter mean diameter and the maximum stable diameter increase with the viscosity, while at higher dispersed phase viscosity, Sauter mean diameter and the maximum stable diameter decreasing and increasing, respectively. It has also been found that linear relation between the Sauter mean diameter and the maximum stable drop diameter is still valid for the emulsions which show a bimodal volume distribution, and the proportional constant decreases as dispersed phase viscosity increases.


2012 ◽  
Vol 69 (5) ◽  
pp. 1534-1546 ◽  
Author(s):  
Olivier P. Prat ◽  
Ana P. Barros ◽  
Firat Y. Testik

Abstract The objective of this study is to evaluate the impact of a new parameterization of drop–drop collision outcomes based on the relationship between Weber number and drop diameter ratios on the dynamical simulation of raindrop size distributions. Results of the simulations with the new parameterization are compared with those of the classical parameterizations. Comparison with previous results indicates on average an increase of 70% in the drop number concentration and a 15% decrease in rain intensity for the equilibrium drop size distribution (DSD). Furthermore, the drop bounce process is parameterized as a function of drop size based on laboratory experiments for the first time in a microphysical model. Numerical results indicate that drop bounce has a strong influence on the equilibrium DSD, in particular for very small drops (<0.5 mm), leading to an increase of up to 150% in the small drop number concentration (left-hand side of the DSD) when compared to previous modeling results without accounting for bounce effects.


2007 ◽  
Vol 24 (6) ◽  
pp. 1019-1032 ◽  
Author(s):  
M. Thurai ◽  
G. J. Huang ◽  
V. N. Bringi ◽  
W. L. Randeu ◽  
M. Schönhuber

Drop shapes derived from a previously conducted artificial rain experiment using a two-dimensional video disdrometer (2DVD) are presented. The experiment involved drops falling over a distance of 80 m to achieve their terminal velocities as well as steady-state oscillations. The previous study analyzed the measured axis ratios (i.e., ratio of maximum vertical to maximum horizontal chord) as a function of equivolumetric spherical drop diameter (Deq) for over 115 000 drops ranging from 1.5 to 9 mm. In this paper, the actual contoured shapes of the drops are reported, taking into account the finite quantization limits of the instrument. The shapes were derived from the fast line-scanning cameras of the 2DVD. The drops were categorized into Deq intervals of 0.25-mm width and the smoothed contours for each drop category were superimposed on each other to obtain their most probable shapes and their variations due to drop oscillations. The most probable shapes show deviation from oblate spheroids for Deq > 4 mm, the larger drops having a more flattened base, in good agreement with the equilibrium (nonoblate) shape model of Beard and Chuang. Deviations were noted from the Beard and Chuang model shapes for diameters larger than 6 mm. However, the 2DVD measurements of the most probable contour shapes are the first to validate the Beard and Chuang model shapes for large drops, and further to demonstrate the differences from the equivalent oblate shapes. The purpose of this paper is to document the differences in radar polarization parameters and the range of error incurred when using the equivalent oblate shapes versus the most probable contoured shapes measured with the 2DVD especially for drop size distributions (DSDs) with large median volume diameters (>2 mm). The measured contours for Deq > 1.5 mm were fitted to a modified conical equation, and scattering calculations were performed to derive the complex scattering amplitudes for forward and backscatter for H and V polarizations primarily at 5.34 GHz (C band) but also at 3 GHz (S band) and 9 GHz (X band). Calculations were also made to derive the relevant dual-polarization radar parameters for measured as well as model-based drop size distributions. When comparing calculations using the contoured shapes against the equivalent oblate spheroid shapes, good agreement was obtained for cases with median volume diameter (D0) less than around 2 mm. Small systematic differences in the differential reflectivity (Zdr) values of up to 0.3 dB were seen for the larger D0 values when using the oblate shapes, which can be primarily attributed to the shape differences in the resonance region, which occurs in the 5.5–7-mm-diameter range at C band. Lesser systematic differences were present in the resonance region at X band (3–4 mm). At S band, the impact of shape differences in the polarimetric parameters were relatively minor for D0 up to 2.5 mm. Unusual DSDs with very large D0 values (>3 mm) (e.g., as can occur along the leading edge of severe convective storms or aloft due localized “big drop” zones) can accentuate the Zdr difference between the contoured shape and the oblate spheroid equivalent, especially at C band. For attenuation-correction schemes based on differential propagation phase, it appears that the equivalent oblate shape approximation is sufficient using a fit to the axis ratios from the 80-m fall experiment given in this paper. For high accuracy in developing algorithms for predicting D0 from Zdr, it is recommended that the fit to the most probable contoured shapes as given in this paper be used especially at C band.


2018 ◽  
Vol 2018 ◽  
pp. 1-15 ◽  
Author(s):  
Xichuan Liu ◽  
Taichang Gao ◽  
Yuntao Hu ◽  
Xiaojian Shu

In order to improve the measurement of precipitation microphysical characteristics sensor (PMCS), the sampling process of raindrops by PMCS based on a particle-by-particle Monte-Carlo model was simulated to discuss the effect of different bin sizes on DSD measurement, and the optimum sampling bin sizes for PMCS were proposed based on the simulation results. The simulation results of five sampling schemes of bin sizes in four rain-rate categories show that the raw capture DSD has a significant fluctuation variation influenced by the capture probability, whereas the appropriate sampling bin size and width can reduce the impact of variation of raindrop number on DSD shape. A field measurement of a PMCS, an OTT PARSIVEL disdrometer, and a tipping bucket rain Gauge shows that the rain-rate and rainfall accumulations have good consistencies between PMCS, OTT, and Gauge; the DSD obtained by PMCS and OTT has a good agreement; the probability of N0, μ, and Λ shows that there is a good agreement between the Gamma parameters of PMCS and OTT; the fitted μ-Λ and Z-R relationship measured by PMCS is close to that measured by OTT, which validates the performance of PMCS on rain-rate, rainfall accumulation, and DSD related parameters.


Metals ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1036
Author(s):  
Eduardo Colin García ◽  
Alejandro Cruz Ramírez ◽  
Guillermo Reyes Castellanos ◽  
José Federico Chávez Alcalá ◽  
Jaime Téllez Ramírez ◽  
...  

Ductile iron camshafts low alloyed with 0.2 and 0.3 wt % vanadium were produced by one of the largest manufacturers of the ductile iron camshafts in México “ARBOMEX S.A de C.V” by a phenolic urethane no-bake sand mold casting method. During functioning, camshafts are subject to bending and torsional stresses, and the lobe surfaces are highly loaded. Thus, high toughness and wear resistance are essential for this component. In this work, two austempering ductile iron heat treatments were evaluated to increase the mechanical properties of tensile strength, hardness, and toughness of the ductile iron camshaft low alloyed with vanadium. The austempering process was held at 265 and 305 °C and austempering times of 30, 60, 90, and 120 min. The volume fraction of high-carbon austenite was determined for the heat treatment conditions by XRD measurements. The ausferritic matrix was determined in 90 min for both austempering temperatures, having a good agreement with the microstructural and hardness evolution as the austempering time increased. The mechanical properties of tensile strength, hardness, and toughness were evaluated from samples obtained from the camshaft and the standard Keel block. The highest mechanical properties were obtained for the austempering heat treatment of 265 °C for 90 min for the ADI containing 0.3 wt % V. The tensile and yield strength were 1200 and 1051 MPa, respectively, while the hardness and the energy impact values were of 47 HRC and 26 J; these values are in the range expected for an ADI grade 3.


Sign in / Sign up

Export Citation Format

Share Document