The Dynamic Behavior of Articulated Pipes Conveying Fluid With Periodic Flow Rate

1974 ◽  
Vol 41 (1) ◽  
pp. 55-62 ◽  
Author(s):  
M. P. Bohn ◽  
G. Herrmann

The plane motion of two rigid, straight articulated pipes conveying fluid is examined. In contrast to previous work, the flow rate is not taken as constant, but is allowed to have small periodic oscillations about a mean value, as would be expected in a pump-driven system. It is shown that in the presence of such disturbances, both parametric and combination resonances are possible. When the system can also admit loss of stabilty by static buckling or by flutter, it is found that the presence of small periodic disturbances constitutes a destabilizing effect. Floquet theory and converging infinite determinant expansions are used to illustrate a basic difference between systems which lose stability by divergence and those that lose stability by flutter. An algebraic criterion is obtained for the minimum amplitude of flow rate oscillation required for the system to be affected by the presence of small disturbances.

1981 ◽  
Vol 48 (4) ◽  
pp. 943-947 ◽  
Author(s):  
J. Rousselet ◽  
G. Herrmann

The plane motion of a cantilevered pipe conveying fluid is examined when the flow velocity is in the neighborhood of that generating flutter. In contrast to previous studies, the flow velocity is not prescribed as a constant, but is determined from the laws of motion. We are thus led to a system of two nonlinear partial differential equations which are coupled through the nonlinear terms. The solution is found by the use of the Krylov-Bogoliubov averaging method and the results are discussed indicating the effect of nonlinearities.


1994 ◽  
Vol 116 (1) ◽  
pp. 57-66 ◽  
Author(s):  
C. O. Chang ◽  
K. C. Chen

This paper deals with the dynamics and stability of simply supported pipes conveying fluid, where the fluid has a small harmonic component of flow velocity superposed on a constant mean value. The perturbation techniques and the method of averaging are used to convert the nonautonomous system into an autonomous one and determine the stability boundaries. Post-bifurcation analysis is performed for the parametric points in the resonant regions where the axial force, which is induced by the transverse motion of the pipe due to the fixed-span ends and contributes nonlinearities to the equations of motion, is included. For the undamped system, linear analysis is inconclusive about stability and there does not exist nontrivial solution in the resonant regions. For the damped system, it is found that the original stable system remains stable when the pulsating frequency increases cross the stability boundary and becomes unstable when the pulsating frequency decreases cross the stability boundary.


2021 ◽  
Vol 37 ◽  
pp. 318-326
Author(s):  
Yuzhen Zhao ◽  
Dike Hu ◽  
Song Wu ◽  
Xinjun Long ◽  
Yongshou Liu

Abstract In this paper, the dynamics of axially functionally graded (AFG) conical pipes conveying fluid are analyzed. The materials are distributed along the conical pipe axis as a volume fraction function. Either the elastic modulus or the density of the AFG conical pipe is assumed to vary from the inlet to the outlet. The governing equation of the AFG conical pipe is derived using the Hamiltonian principle and solved by the differential quadrature method. The effects of the volume fraction index, volume fraction function type and reduction factor on the natural frequency and critical velocity are analyzed. It is found that for a power function volume fraction type, the natural frequency and critical velocity increase with increasing volume fraction index and clearly increase when the volume fraction index is within the range (0, 10). For an exponential function volume fraction type, the natural frequency and critical velocity change rapidly within the range (−10, 10), besides the above range the relationship between the natural frequency, critical velocity and volume fraction index is approximate of little change. The natural frequency and critical velocity decrease linearly with increasing reduction factor.


2021 ◽  
Vol 11 (11) ◽  
pp. 4941
Author(s):  
Fan Yang ◽  
Yiqi Zhang ◽  
Yao Yuan ◽  
Chao Liu ◽  
Zhongbin Li ◽  
...  

In order to study the variation law of the flow field and pressure fluctuation in the hump section of the siphon outlet conduit, the flow field characteristics and frequency spectrum characteristics of the flow field were analyzed by combining a physical model test and numerical simulation under the conditions of the interaction between the axial flow pump and siphon outlet conduit, and the influence of the residual circulation at the outlet of the guide vane on the siphon outlet flow was investigated. Based on the influence of the flow field and hydraulic loss in the conduit, the equivalent surface method based on the Q criterion was used to analyze the vortex structure in the siphon outlet conduit and to analyze the internal vortex state. The results showed that with the increase of the flow rate, the intensity of the vortices in the cross-section of the hump section of the siphon outlet conduit decreased gradually, the average velocity circulation decreased gradually and the axial velocity distribution uniformity increased and tended to be stable; water flow stratification existed under three characteristic conditions with no circulation, and the hydraulic loss was greater with the circulation flow while it had a circulation under the small flow condition. Under the low flow rate conditions, the hydraulic loss was 6.6 times higher under the condition of circulation than without. Under a high flow condition, it was 1.3 times. Under the condition of a small flow rate, the vortex structure was distributed centrally at the inlet of the flow conduit, and under the other two characteristic conditions, the vortex structure mostly appeared as a strip; the pressure fluctuation in the hump section had obvious periodicity, and with the increase of the flow rate, the maximum pressure fluctuation amplitude in the hump section decreased gradually; with the decrease of the rotational speed, the pressure amplitude at the same measuring point in the hump section decreased gradually and at the optimum condition. Under the following conditions, the mean value of the pressure amplitude at the top of the hump section was reduced by 69.63%, and the mean value of the pressure amplitude at the bottom of the hump section was reduced by 63.5%. Under all the calculation conditions, the main frequency of pulsation at each measuring point of the hump section was twice the frequency of the rotation.


2021 ◽  
pp. 155335062110148
Author(s):  
Umberto Bracale ◽  
Vania Silvestri ◽  
Emanuele Pontecorvi ◽  
Immacolata Russo ◽  
Maria Triassi ◽  
...  

Background. The COVID-19 pandemic leads to several debates regarding the possible risk for healthcare professionals during surgery. SAGES and EAES raised the issue of the transmission of infection through the surgical smoke during laparoscopy. They recommended the use of smoke evacuation devices (SEDs) with CO2 filtering systems. The aim of the present study is to compare the efficacy of different SEDs evaluating the CO2 environmental dispersion in the operating theater. Methods. We prospectively evaluated the data of 4 group of patients on which we used different SEDs or standard trocars: AIRSEAL system (S1 group), a homemade device (S2 group), an AIRSEAL system + homemade device (S3 group), and with standard trocars and without SED (S4 group). Quantitative analysis of CO2 environmental dispersion was carried out associated to the following data in order to evaluate the pneumoperitoneum variations: a preset insufflation pressure, real intraoperative pneumoperitoneum pressure, operative time, total volume of insufflated CO2, and flow rate index. Results. 16 patients were prospectively enrolled. The [CO2] mean value was 711 ppm, 641 ppm, 593 ppm, and 761 ppm in S1, S2, S3, and S4 groups, respectively. The comparison between data of all groups showed statistically significant differences in the measured ambient CO2 concentration. Conclusion. All tested SEDs seem to be useful to reduce the CO2 environmental dispersion respect to the use of standard trocars. The association of AIRSEAL system and a homemade device seems to be the best solution combining an adequate smoke evacuation and a stable pneumoperitoneum during laparoscopic surgery.


Sign in / Sign up

Export Citation Format

Share Document