Air Infiltration and Building Tightness Measurements in Passive Solar Residences

1984 ◽  
Vol 106 (2) ◽  
pp. 193-197 ◽  
Author(s):  
A. K. Persily ◽  
R. A. Grot

The airtightness of about fifty passive solar homes located throughout the United States was studied using low-cost measurement techniques. These homes are part of the DOE-sponsored Class B monitoring program conducted at the Solar Energy Research Institute (SERI) to evaluate the thermal performance of passive solar residential buildings. These tests provide the first set of building tightness measurements on a large group of passive solar buildings. The measurements include pressurization tests to measure airtightness and tracer gas measurements to determine air infiltration rates. The pressure tests show a variation in the air-tightness of these homes from 3 to 30 exchanges/hr at 50 Pascal, with a median of 9.5 exchanges/hr. The air infiltration measurements cover a wider range from 0.05 to 3.0 exchanges/hr, with a median of 0.5 exchanges/hr. In comparing the tightness of these homes to other U.S. homes, one finds that these passive solar homes are not significantly tighter than homes built with less of an emphasis on energy use.

1989 ◽  
Vol 161 ◽  
Author(s):  
Harin S. Ullal ◽  
Kenneth Zweibel ◽  
Richard L. Mitchell

ABSTRACTThe Polycrystalline Thin Film Solar Cells Program, part of the United States National Photovoltaic Program, performs R&D on copper indium diselenide and cadmium telluride thin films. The objective of the Program is to support research to develop cells and modules that meet the U.S. Department of Energy's long-term goals by achieving high efficiencies (15% - 20%), low-cost ($50/M2), and long-time reliability (30 years). The importance of work in this area is due to the fact that the polycrystalline thin-film CuInSe2 and CdTe solar cells and modules have made rapid advances. They have become the leading thin films for PV in terms of efficiency and stability. The U.S. Department of Energy has increased its funding through an initiative through the Solar Energy Research Institute in CuInSe2and CdTe with subcontracts to start in Spring 1990.


Author(s):  
R.G. Nelson, ◽  
C.H. Hellwinckel, ◽  
C.C. Brandt, ◽  
T.O. West, ◽  
D.G. De La Torre Ugarte, ◽  
...  

2020 ◽  
Vol 17 (1) ◽  
pp. 41
Author(s):  
UMMU SHOLEHAH MOHD NOR

High residential living in Malaysia has not been widely given a significant emphasises in literature despite its increasing scale and significance in the real estate market. The significance of high rise is mainly due the increasing rate of migration from rural to urban. It is estimated a total of 77.2 percent of the Malaysian population lived in urban areas in 2020. Approximately, 30 percent of this urban population lives in strata housing. These percentages are predicted to continue to increase in the future. The emergence of high residential building has been argued as confronting various problems which has considerable impact on this life style. Satisfaction is an important outcome of living in one’s dwelling, although it is not the only consideration. High residential building in Malaysia encountered numerous problems in term of management aspects, legislation aspects, and residents’ satisfaction. The purpose of this paper is to investigate the tenants’ satisfaction living in high residential buildings in Klang Valley. The questionnaires survey is conducted amongst 276 tenants at low cost and medium cost HRB using random sampling in HRB located at areas under jurisdiction Dewan Bandaraya Kuala Lumpur (DBKL), Majlis Bandaraya Subang Jaya (MBSJ), Majlis Bandaraya Shah Alam (MBSA), Majlis Bandaraya Subang Jaya (MBSJ), Majlis Perbandaran Selayang (MPS) and Majlis Perbandaran Ampang Jaya (MPAJ). The result from this study shows that tenant in medium cost residential building are more satisfied in term of facilities and management as compared to tenants in low cost residential building. Tenants also not disclosed to the existing act and procedure related to high residential building. In conclusion, this study suggested the Local Authority to emphasise the role of tenant. These recommendation hopefully will increase the level of satisfaction amongst the residents in HRB.


2021 ◽  
Vol 11 (9) ◽  
pp. 3972
Author(s):  
Azin Velashjerdi Farahani ◽  
Juha Jokisalo ◽  
Natalia Korhonen ◽  
Kirsti Jylhä ◽  
Kimmo Ruosteenoja ◽  
...  

The global average air temperature is increasing as a manifestation of climate change and more intense and frequent heatwaves are expected to be associated with this rise worldwide, including northern Europe. Summertime indoor conditions in residential buildings and the health of occupants are influenced by climate change, particularly if no mechanical cooling is used. The energy use of buildings contributes to climate change through greenhouse gas emissions. It is, therefore, necessary to analyze the effects of climate change on the overheating risk and energy demand of residential buildings and to assess the efficiency of various measures to alleviate the overheating. In this study, simulations of dynamic energy and indoor conditions in a new and an old apartment building are performed using two climate scenarios for southern Finland, one for average and the other for extreme weather conditions in 2050. The evaluated measures against overheating included orientations, blinds, site shading, window properties, openable windows, the split cooling unit, and the ventilation cooling and ventilation boost. In both buildings, the overheating risk is high in the current and projected future average climate and, in particular, during exceptionally hot summers. The indoor conditions are occasionally even injurious for the health of occupants. The openable windows and ventilation cooling with ventilation boost were effective in improving the indoor conditions, during both current and future average and extreme weather conditions. However, the split cooling unit installed in the living room was the only studied solution able to completely prevent overheating in all the spaces with a fairly small amount of extra energy usage.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4180
Author(s):  
Joowook Kim ◽  
Michael Brandemuehl

Several building energy simulation programs have been developed to evaluate the indoor conditions and energy performance of buildings. As a fundamental component of heating, ventilating, and air conditioning loads, each building energy modeling tool calculates the heat and moisture exchange among the outdoor environment, building envelope, and indoor environments. This paper presents a simplified heat and moisture transfer model of the building envelope, and case studies for building performance obtained by different heat and moisture transfer models are conducted to investigate the contribution of the proposed steady-state moisture flux (SSMF) method. For the analysis, three representative humid locations in the United States are considered: Miami, Atlanta, and Chicago. The results show that the SSMF model effectively complements the latent heat transfer calculation in conduction transfer function (CTF) and effective moisture penetration depth (EMPD) models during the cooling season. In addition, it is found that the ceiling part of a building largely constitutes the latent heat generated by the SSMF model.


Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2917
Author(s):  
Mohammad Dabbagh ◽  
Moncef Krarti

This paper evaluates the potential energy use and peak demand savings associated with optimal controls of switchable transparent insulation systems (STIS) applied to smart windows for US residential buildings. The optimal controls are developed based on Genetic Algorithm (GA) to identify the automatic settings of the dynamic shades. First, switchable insulation systems and their operation mechanisms are briefly described when combined with smart windows. Then, the GA-based optimization approach is outlined to operate switchable insulation systems applied to windows for a prototypical US residential building. The optimized controls are implemented to reduce heating and cooling energy end-uses for a house located four US locations, during three representative days of swing, summer, and winter seasons. The performance of optimal controller is compared to that obtained using simplified rule-based control sets to operate the dynamic insulation systems. The analysis results indicate that optimized controls of STISs can save up to 81.8% in daily thermal loads compared to the simplified rule-set especially when dwellings are located in hot climates such as that of Phoenix, AZ. Moreover, optimally controlled STISs can reduce electrical peak demand by up to 49.8% compared to the simplified rule-set, indicating significant energy efficiency and demand response potentials of the SIS technology when applied to US residential buildings.


SLEEP ◽  
2021 ◽  
Vol 44 (Supplement_2) ◽  
pp. A259-A259
Author(s):  
Melissa Malinky ◽  
Abigail Oberla ◽  
Meena Khan ◽  
M Melanie Lyons

Abstract Introduction In 2019, the United States Census estimated 8% (26.1 million) people were without health insurance. Further, an estimated 3.5 million people became/remained uninsured from COVID-19-related job losses. Patients with OSA that belong to a lower socioeconomic status (SES) are less likely to have access to healthcare and may be under or uninsured. Untreated OSA can lead to increased risk of symptoms and associated co-morbidities. Resources to help the uninsured to obtain PAP therapy were available pre-COVID, including two main sources, American Sleep Apnea Association (ASAA) and our local branch serving central Ohio, The Breathing Association. However, the COVID pandemic limited access or closed these programs. Our Sleep Medicine clinics saw 148 uninsured OSA patients between March-December, 2020. Given these difficulties, we re-evaluated available resources for the uninsured. Methods We conducted a search for current low cost ($100 or less) PAP therapy options for the uninsured, March 15, 2020-December 3, 2020, by: (1) contacting pre-COVID-19 resources, including Durable Medical Equipment (DME) providers, (2) consulting social work, and (3) completing a librarian assisted web-search not limited to PubMed, Embase, CINAHL for academic related articles and electronic searches using a combination of English complete word and common keywords: OSA, PAP, uninsured, no insurance, cheap, medically uninsured, resources, self-pay, low-income, financial assistance, US. Resources such as private sellers were not investigated. Results During COVID-19, assistance for PAP machines/supplies have closed or required a protracted wait-time. Options including refurbished items range from low, one-time fixed cost or income-based discounts from: one local charity (Joint Organization for Inner-City Needs) and DME (Dasco), and four national entities (ASAA, Second Wind CPAP, Reggie White Foundation, CPAP Liquidators). An Electronic Health Record-based tool was developed and distributed to increase provider awareness of pandemic available resources. Conclusion Untreated OSA is associated with increased risk of cardiovascular co-morbidities. Access and cost may limit treatment in OSA patients from a lower SES. The COVID-19 pandemic has shuttered programs providing discount PAP and supplies, leaving fewer resources for these patients, thus further widening this health care disparity. Alternatives are needed and current resources are not easily accessible for providers and patients. Support (if any):


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3876
Author(s):  
Sameh Monna ◽  
Adel Juaidi ◽  
Ramez Abdallah ◽  
Aiman Albatayneh ◽  
Patrick Dutournie ◽  
...  

Since buildings are one of the major contributors to global warming, efforts should be intensified to make them more energy-efficient, particularly existing buildings. This research intends to analyze the energy savings from a suggested retrofitting program using energy simulation for typical existing residential buildings. For the assessment of the energy retrofitting program using computer simulation, the most commonly utilized residential building types were selected. The energy consumption of those selected residential buildings was assessed, and a baseline for evaluating energy retrofitting was established. Three levels of retrofitting programs were implemented. These levels were ordered by cost, with the first level being the least costly and the third level is the most expensive. The simulation models were created for two different types of buildings in three different climatic zones in Palestine. The findings suggest that water heating, space heating, space cooling, and electric lighting are the highest energy consumers in ordinary houses. Level one measures resulted in a 19–24 percent decrease in energy consumption due to reduced heating and cooling loads. The use of a combination of levels one and two resulted in a decrease of energy consumption for heating, cooling, and lighting by 50–57%. The use of the three levels resulted in a decrease of 71–80% in total energy usage for heating, cooling, lighting, water heating, and air conditioning.


Sign in / Sign up

Export Citation Format

Share Document