scholarly journals Rotor–Stator Interaction in a Diffuser Pump

1989 ◽  
Vol 111 (3) ◽  
pp. 213-221 ◽  
Author(s):  
N. Arndt ◽  
A. J. Acosta ◽  
C. E. Brennen ◽  
T. K. Caughey

The interaction between impeller blades and diffuser vanes in a diffuser pump was investigated. Steady and unsteady pressure measurements were taken on the diffuser vanes, and the shroud wall of a vaned and a vaneless diffuser. Steady, unsteady, and ensemble-averaged unsteady data, as well as frequency spectra, are presented. The measurements were made for different flow coefficients, shaft speeds, and radial gaps between impeller blade trailing and diffuser vane leading edge (1.5 and 4.5 percent based on impeller discharge radius). The resulting lift on the vane, both steady and unsteady, was computed from the pressure measurements at midvane height. The magnitude of the fluctuating lift was found to be greater than the steady lift. The pressure fluctuations were larger on the suction side than on the pressure side attaining their maximum value, of the same order of magnitude as the total pressure rise across the pump, near the leading edge. Pressure fluctuations were also measured across the span of the vane, and those near the shroud were significantly smaller than those near the hub. The pressure fluctuations on the shroud wall itself were larger for the vaned diffuser than a vaneless diffuser. Lift, vane pressure, and shroud wall pressure fluctuations decreased strongly with increasing radial gap.

Author(s):  
N. Arndt ◽  
A. J. Acosta ◽  
C. E. Brennen ◽  
T. K. Caughey

This paper describes an experimental investigation of rotor–stator interaction in a centrifugal pump with several vaned diffusers. Steady and unsteady diffuser vane pressure measurements were made for a two–dimensional test impeller. Unsteady impeller blade pressure measurements were made for a second two–dimensional impeller with blade number and blade geometry identical to the two–dimensional impeller used for the diffuser vane pressure measurements. The experiments were conducted for different flow coefficients and different radial gaps between the impeller blade trailing edge and the diffuser vane leading edge (5% and 8% of the impeller discharge radius). The largest pressure fluctuations on the diffuser vanes and the impeller blades were found to be of the same order of magnitude as the total pressure rise across the pump. The largest pressure fluctuations on the diffuser vanes were observed to occur on the suction side of the vane near the vane leading edge, whereas on the impeller blades the largest fluctuations were observed to occur at the blade trailing edge. However, the dependence of the fluctuations on the flow coefficient was found to be different for the diffuser vanes and the impeller blades; on the vane suction side, the fluctuations were largest for the maximum flow coefficient and decreased with decreasing flow coefficient, whereas at the blade trailing edge, the fluctuations were smallest for the maximum flow coefficient and increased with decreasing flow coefficient. Increasing the number of the diffuser vanes resulted in a significant decrease of the impeller blade pressure fluctuations. The resulting lift on the diffuser vanes was computed from the vane pressure measurements; the magnitude of the fluctuating lift was found to be larger than the steady lift.


1990 ◽  
Vol 112 (1) ◽  
pp. 98-108 ◽  
Author(s):  
N. Arndt ◽  
A. J. Acosta ◽  
C. E. Brennen ◽  
T. K. Caughey

This paper describes an experimental investigation of rotor-stator interaction in a centrifugal pump with several vaned diffusers. Steady and unsteady diffuser vane pressure measurements were made for a two-dimensional test impeller. Unsteady impeller blade pressure measurements were made for a second two-dimensional impeller with blade number and blade geometry identical to the two-dimensional impeller used for the diffuser vane pressure measurements. The experiments were conducted for different flow coefficients and different radial gaps between the impeller blade trailing edge and the diffuser vane leading edge (5 and 8 percent of the impeller discharge radius). The largest pressure fluctuations on the diffuser vanes and the impeller blades were found to be of the same order of magnitude as the total pressure rise across the pump. The largest pressure fluctuations on the diffuser vanes were observed to occur on the suction side of the vane near the vane leading edge, whereas on the impeller blades the largest fluctuations were observed to occur at the blade trailing edge. However, the dependence of the fluctuations on the flow coefficient was found to be different for the diffuser vanes and the impeller blades; on the vane suction side, the fluctuations were largest for the maximum flow coefficient and decreased with decreasing flow coefficient, whereas at the blade trailing edge, the fluctuations were smallest for the maximum flow coefficient and increased with decreasing flow coefficient. Increasing the number of the diffuser vanes resulted in a significant decrease of the impeller blade pressure fluctuations. The resulting lift on the diffuser vanes was computed from the vane pressure measurements; the magnitude of the fluctuating lift was found to be larger than the steady lift.


2020 ◽  
Vol 142 (7) ◽  
Author(s):  
M. Awasthi ◽  
J. Rowlands ◽  
D. J. Moreau ◽  
C. J. Doolan

Abstract Measurements of the wall pressure fluctuations near a wing-plate junction were made for wings with three different aspect ratios (AR) of 0.2, 0.5, and 1.0 at several angles of attack. The chord-based Reynolds number for each wing was 274,000. The results show that the wall pressure fluctuations are a function of wing AR for cases where AR≤ 1.0. For each wing, the pressure fluctuations are highest upstream of the wing leading-edge due to three-dimensional flow separation; wings with AR = 1.0 and 0.5 show comparable levels, while those with AR = 0.2 show lower fluctuation levels over a wide frequency range. Downstream of the leading-edge, the pressure fluctuations decay rapidly on both sides of the wing until the maximum thickness location after which little variation is observed. The pressure fluctuations downstream of the leading-edge on the suction-side were observed to be comparable for AR = 0.2 and 0.5, while those for AR = 1.0 were higher in magnitude. On the pressure-side, the pressure fluctuations near the leading-edge are a weak function of AR; however, those further downstream remain independent of AR. The pressure fluctuations aft of the wing on the suction-side are more coherent for lower ARs and show higher convection velocity, possibly due to an interaction between the tip and the junction flows for lower ARs.


Author(s):  
Jiayi Zhao ◽  
Guang Xi ◽  
Zhiheng Wang ◽  
Yang Zhao

The spike-type rotating stall (RS) inception inside the vaned-diffuser, which seriously restricts the performance range and brings the problems of blade fatigue, still seems to be a ‘mystery’ since its randomness. The paper intends to explain the mechanisms of this stall inception. To quantitatively assess the critical unsteady behavior to the initiation of RS inception, the transient measurement characterizes the process falling into the RS through the parameter of ‘blade passing irregularity’. The underlying vortex disturbance, related to the growing of the flow complexity and the final spike-type precursor, is further revealed by the full-annulus simulation. The results show the propagation principle of the vortexes from the design to the stall inception point, reflected by the distribution of ‘blade passing irregularity’. The performance change of different sub-components due to the vortex behavior is presented. At the RS limit, the sudden ramp-up of the ‘blade passing irregularity’ near the leading edge (LE), accompanied with the drop of the static pressure rise in the sub-component between the semi-vaneless and throat, corresponds to the spike-type inception in the form of a clockwise vortex connecting the suction side of the diffuser vane and the pressure side of the adjacent vane. Besides, when approaching the spike-type inception point, the couple effect of the growing potential of the diffuser vane and the enhanced vortex disturbance at the impeller outlet degrades the diffuser inlet flow.


Author(s):  
Alain Guedel ◽  
Mirela Robitu ◽  
Nicolas Descharmes ◽  
Didier Amor ◽  
Je´rome Guillard

The objective of this work is to predict the trailing-edge noise of axial fans with an analytical model deduced from an extension of Amiet’s formulation. The input data of the acoustic model are the frequency spectra and the spanwise correlation length scales of the wall-pressure fluctuations on the blade suction side close to the trailing edge. This model was successfully validated in former studies on single steady airfoils in anechoic wind tunnels and, to a lesser extent, on an axial fan equipped with small unsteady pressure transducers flush mounted on the blade suction side. The present research is carried out on a 6-blade axial fan no longer equipped with embedded pressure transducers. The input data of the prediction are then deduced from non-dimensional spectra and correlation lengths of the pressure fluctuations measured in the previous study and RANS simulations performed on the test fan. A validation of the prediction method is made by comparing the predicted and measured sound power spectra of the fan for two blade pitch angles and different operating points.


2016 ◽  
Vol 138 (12) ◽  
Author(s):  
Antonio Posa ◽  
Antonio Lippolis ◽  
Elias Balaras

Turbopumps operating at reduced flow rates experience significant separation and backflow phenomena. Although Reynolds-Averaged Navier–Stokes (RANS) approaches proved to be usually able to capture the main flow features at design working conditions, previous numerical studies in the literature verified that eddy-resolving techniques are required in order to simulate the strong secondary flows generated at reduced loads. Here, highly resolved large-eddy simulations (LES) of a radial pump with a vaned diffuser are reported. The results are compared to particle image velocimetry (PIV) experiments in the literature. The main focus of the present work is to investigate the separation and backflow phenomena occurring at reduced flow rates. Our results indicate that the effect of these phenomena extends up to the impeller inflow: they involve the outer radii of the impeller vanes, influencing significantly the turbulent statistics of the flow. Also in the diffuser vanes, a strong spanwise evolution of the flow has been observed at the reduced load, with reverse flow, located mainly on the shroud side and on the suction side (SS) of the stationary channels, especially near the leading edge of the diffuser blades.


2017 ◽  
Vol 833 ◽  
pp. 563-598 ◽  
Author(s):  
Hiroyuki Abe

Direct numerical simulations are used to examine the behaviour of wall-pressure fluctuations $p_{w}$ in a flat-plate turbulent boundary layer with large adverse and favourable pressure gradients, involving separation and reattachment. The Reynolds number $Re_{\unicode[STIX]{x1D703}}$ based on momentum thickness is equal to 300, 600 and 900. Particular attention is given to effects of Reynolds number on root-mean-square (r.m.s.) values, frequency/power spectra and instantaneous fields. The possible scaling laws are also examined as compared with the existing direct numerical simulation and experimental data. The r.m.s. value of $p_{w}$ normalized by the local maximum Reynolds shear stress $-\unicode[STIX]{x1D70C}\overline{uv}_{max}$ (Simpson et al. J. Fluid Mech. vol. 177, 1987, pp. 167–186; Na & Moin J. Fluid Mech. vol. 377, 1998b, pp. 347–373) leads to near plateau (i.e. $p_{w\,rms}/-\unicode[STIX]{x1D70C}\overline{uv}_{max}=2.5\sim 3$) in the adverse pressure gradient and separated regions in which the frequency spectra exhibit good collapse at low frequencies. The magnitude of $p_{w\,rms}/-\unicode[STIX]{x1D70C}\overline{uv}_{max}$ is however reduced down to 1.8 near reattachment where good collapse is also obtained with normalization by the local maximum wall-normal Reynolds stress $\unicode[STIX]{x1D70C}\overline{vv}_{max}$. Near reattachment, $p_{w\,rms}/-\unicode[STIX]{x1D70C}\overline{vv}_{max}=1.2$ is attained unambiguously independently of the Reynolds number and pressure gradient. The present magnitude (1.2) is smaller than (1.35) obtained for step-induced separation by Ji & Wang (J. Fluid Mech. vol. 712, 2012, pp. 471–504). The reason for this difference is intrinsically associated with convective nature of a pressure-induced separation bubble near reattachment where the magnitude of $p_{w\,rms}$ depends essentially on the favourable pressure gradient. The resulting mean flow acceleration leads to delay of the r.m.s. peak after reattachment. Attention is also given to structures of $p_{w}$. It is shown that large-scale spanwise rollers of low pressure fluctuations are formed above the bubble, whilst changing to large-scale streamwise elongated structures after reattachment. These large-scale structures become more prominent with increasing $Re_{\unicode[STIX]{x1D703}}$ and affect $p_{w}$ significantly.


Author(s):  
Till M. Biedermann ◽  
F. Kameier ◽  
C. O. Paschereit

Abstract Leading edge serrations are identified as an effective passive treatment for reducing fan broadband noise due to high turbulent inflow conditions. This paper aims to investigate the isolated effect of serrated applications in a rotating frame, covering the aerodynamic and aeroacoustic performance. With this purpose, a serration design, previously analyzed in the rigid domain, is transferred to the rotating frame, following a successive approach in form of a continuous increase of the fan blade number. This is considered as a feasible way to isolate the serration effects and to provide information on fan blade interaction and possible masking effects. Comparing blades with straight and serrated leading edges by analyzing the spectral noise reduction and the overall level result in deep insights in the underlying noise reduction mechanisms. Furthermore, analysis of phase differences by means of the wall pressure fluctuations leads to the identification of rotating flow phenomena, nonsynchronized with the rotor speed. The results obtained indicate an efficient noise reduction by the serrations in the vicinity of the design point. By use of the presented successive approach, noise reduction phenomena observed with the full rotor could be identified to be of either aeroacoustic or aerodynamic nature. A reduced noise is observed for the full rotor case, showing a reduction of blade interaction effects. At reducing flow coefficients, an improved stall margin of the serrated rotor is identified that also affects the aeroacoustic signature.


Author(s):  
Hongwei Ma ◽  
Jun Zhang

The purpose of this paper is to investigate numerically the effects of the tip geometry on the performance of an axial compressor rotor. There are three case studies which are compared with the base line tip geometry. 1) baseline (flat tip); 2) Cavity (tip with a cavity); 3) SSQA (suction side squealer tip) and 4) SSQB (modified suction side squealer tip). The case of SSQB is a combination of suction side squealer tip and the cavity tip. From leading edge to 10% chord, the tip has a cavity. From 10% chord to trailing edge, the tip has a suction side squealer. The numerical results of 2) show that the cavity tip leads to lower leakage mass flow and greater loss in tip gap and the rotor passage. The loading near the blade tip is lower than the baseline, thus the tangential force of the blade is lower. It leads to lower pressure rise than the baseline. The performance of the compressor for the tip with cavity is worse than the baseline. The results of 3) show that the higher curvature of the suction side squealer increases the loading of the blade and the tangential blade force. With the suction side squealer tip, the leakage flow experiences two vena contractor thus the mass of the leakage flow is reduced which is benefit for the performance of the compressor. The loss in the tip gap is lower than baseline. The performance is better than the baseline with greater pressure rise of the rotor, smaller leakage mass flow and lower averaged loss. For the case the SSQB, the leakage mass flow is lower than the SSQA and the loss in the tip gap and the rotor passage is greater than SSQA. The performance of the case of the SSQB is worse than the case of SSQA.