Condensation Measurement of Horizontal Cocurrent Steam/Water Flow

1984 ◽  
Vol 106 (2) ◽  
pp. 425-432 ◽  
Author(s):  
I. S. Lim ◽  
R. S. Tankin ◽  
M. C. Yuen

Condensation of steam on a subcooled water layer was studied in a cocurrent horizontal channel at atmospheric pressure. The heat transfer coefficients were found to vary from 1.3 kW/m2°C to 20 kW/m2°C, depending on whether the liquid interface was smooth or wavy, increased with increasing steam flow rates and water flow rates. For all cases, 50 to 90 percent of the steam condensed within 1.2 m from the entrance. The average Nusselt numbers were correlated with average steam and water Reynolds numbers and average liquid Prandtl numbers, for both smooth and wavy interface flows. Finally, a correlation of the average heat transfer coefficient and condensation rate for wavy interface flow was obtained as a function of inlet conditions and distance downstream.

2005 ◽  
Vol 128 (6) ◽  
pp. 557-563 ◽  
Author(s):  
Paul L. Sears ◽  
Libing Yang

Heat transfer coefficients were measured for a solution of surfactant drag-reducing additive in the entrance region of a uniformly heated horizontal cylindrical pipe with Reynolds numbers from 25,000 to 140,000 and temperatures from 30to70°C. In the absence of circumferential buoyancy effects, the measured Nusselt numbers were found to be in good agreement with theoretical results for laminar flow. Buoyancy effects, manifested as substantially higher Nusselt numbers, were seen in experiments carried out at high heat flux.


1983 ◽  
Vol 105 (3) ◽  
pp. 433-439 ◽  
Author(s):  
N. Seki ◽  
S. Fukusako ◽  
A. Yamaguchi

Experimental measurements are presented for free convective heat transfer across a parallelogrammic enclosure with the various tilt angles of parallel upper and lower walls insulated. The experiments covered a range of Rayleigh numbers between 3.4 × 104 and 8.6 × 107, and Prandtl numbers between 0.70 and 480. Those also covered the tilt angles of the parallel insulated walls with respect to the horizontal, φ, of 0, ±25, ±45, ±60, and ±70 deg under an aspect ratio of H/W = 1.44. The fluids used were air, transformer oil, and water. It was found that the heat transfer coefficients for φ = −70 deg were decreased to be about 1/18 times those for φ = 0 deg. Experimental results are given as plots of the Nusselt number versus the Rayleigh number. A correlation equation is given for the Nusselt number, Nu, as a function of φ, Pr, and Ra.


Author(s):  
G. Qureshi ◽  
M. H. Nguyen ◽  
N. R. Saad ◽  
R. N. Tadros

To optimise the turbine disc weight and coolant flow requirements, the aspect of improving thermal analysis was investigated. As a consequence, an experimental investigation was undertaken to measure the rates of convective heat transfer. The constant temperature steady state technique was used to determine the local and average heat transfer coefficients on the sides of rotating discs. The effects of coolant flow rates, CW (3000 ≤ CW ≤ 18600) with two types of cavity in-flow conditions and of the rotational speeds, Reθ (from 4×105 to 1.86×106) on the disc heat transfer were studied and correlations developed. For a rotating disc in confined cavities with superimposed coolant flows, Nusselt numbers were found to be higher than those for the free rotating disc without confinement.


1959 ◽  
Vol 81 (1) ◽  
pp. 24-28 ◽  
Author(s):  
Samuel Globe ◽  
David Dropkin

This paper presents results of an experimental investigation of convective heat transfer in liquids placed between two horizontal plates and heated from below. The liquids used were water, silicone oils of 1.5, 50, and 1000 centistoke kinematic viscosities, and mercury. The experiments covered a range of Rayleigh numbers between 1.51(10)5 and 6.76(10)8. and Prandtl numbers between 0.02 and 8750. Tests were made in cylindrical containers having copper tops and bottoms and insulating walls. For water and silicone oils the container was 5 in. in diam and 2 in. high. For mercury, two containers were used, both 5.28 in. in diameter, but one 1.39 in. high and another 2.62 in. high. In all cases the bottom plates were heated by electric heaters. The top plates were air-cooled for the water and silicone-oil experiments and water-cooled for the mercury tests. To prevent amalgamation, the copper plates of the mercury container were chromium plated. Surface temperatures were measured by thermocouples embedded in the plates. The test results indicate that the heat-transfer coefficients for all liquids investigated may be determined from the relationship Nu=0.069Ra13Pr0.074 In this equation the Nusselt and Rayleigh numbers are based on the distance between the copper plates. The results of this experiment are in reasonable agreement with the data reported by others who used larger containers and different fluids.


Author(s):  
Bin Ren ◽  
Xiaoying Tang ◽  
Hongliang Lu ◽  
Dongliang Fu ◽  
Yannan Du ◽  
...  

It is the simplest and most feasible method to enhance heat transfer by replacing the smooth tube with various kinds of special-shaped enhanced tubes. In this paper, the characteristics of condensation and flow resistance inside horizontal corrugated low finned tubes were studied experimentally. The effects of steam inlet conditions and condensation tubes structural parameters were analyzed. The results showed that the heat transfer performance inside corrugated low finned tubes was greater than that inside smooth tubes. Like inside smooth tubes, the heat transfer coefficients increased with the vapor quality and steam mass flux. But the enhancement rate showed the opposite trend. And the heat transfer coefficients inside corrugated low finned tubes increased with the decrease of pitch and increase of protrusion height. Meanwhile, the variation trend of pressure drop gradient changing with inlet conditions and construal parameters was consistent with trend of heat transfer coefficient. The performance evaluation criteria were used to evaluate the comprehensive performance. It was found that the maximum performance evaluation factor was acquired at the minimum vapor quality and mass flux. The maximum value was 2.24 happened in the tube with pitch of 6 mm and height of 0.7mm. Finally, both the correlation for heat transfer coefficient and correlation for pressure drop gradient were developed by fitting experimental data. And this would provide calculation foundations for the design of horizontal condensers with corrugated low finned tubes.


2014 ◽  
Vol 136 (8) ◽  
Author(s):  
Yutaka Ito ◽  
Naoya Inokura ◽  
Takao Nagasaki

A light and compact heat exchange system was realized using two air-to-refrigerant airfoil heat exchangers and a recirculated heat transport refrigerant. Its heat transfer performance was experimentally investigated. Carbon dioxide or water was used as a refrigerant up to a pressure of 30 MPa. Heat transfer coefficients on the outer air-contact and inner refrigerant-contact surfaces were calculated using an inverse heat transfer method. Correlations were developed for the Nusselt numbers of carbon dioxide and water on the inner refrigerant-contact surface. Furthermore, we proposed a method to evaluate a correction factor corresponding to the thermal resistance of the airfoil heat exchanger.


Author(s):  
Reby Roy ◽  
B. V. S. S. S. Prasad ◽  
S. Srinivasa Murthy

The conjugate heat transfer in a stationary cylindrical cavity with a rotating disk and fluid through-flow is analysed at various rotational speeds ranging from 10000 to 50000 rpm by using a finite volume commercial code. The numerical model and code are validated for a problem, which involves rotation and fluid through-flow. A reduction of the thermal boundary layer thickness and increase in the heat transfer coefficients are observed with increase in the rotational speed. Marked differences are noticed between the Nusselt numbers obtained from the conjugate and constant temperature analyses.


1994 ◽  
Vol 116 (4) ◽  
pp. 721-729 ◽  
Author(s):  
S. Ou ◽  
J.-C. Han ◽  
A. B. Mehendale ◽  
C. P. Lee

The effect of unsteady wake flow and air (D.R. = 1.0) or CO2 (D.R. = 1.52) film injection on blade heat transfer coefficients was experimentally determined. A spoked wheel-type wake generator produced the unsteady wake. Experiments were performed on a five-airfoil linear cascade in a low-speed wind tunnel at the chord Reynolds number of 3 × 105 for the no-wake case and at the wake Strouhal numbers of 0.1 and 0.3. Results from a blade with three rows of film holes in the leading edge region and two rows each on the pressure and suction surfaces show that the Nusselt numbers are much higher than those for the blade without film holes. On a large portion of the blade, the Nusselt numbers “without wake but with film injection” are much higher than for “with wake but no film holes.” An increase in wake Strouhal number causes an increase in pressure surface Nusselt numbers; but the increases are reduced at higher blowing ratios. As blowing ratio increases, the Nusselt numbers for both density ratio injectants (air and CO2) increase over the entire blade except for the transition region where the effect is reversed. Higher density injectant (CO2) produces lower Nusselt numbers on the pressure surface, but the numbers for air and CO2 injections are very close on the suction surface except for the transition region where the numbers for CO2 injection are higher. From this study, one may conclude that the additional increases in Nusselt numbers due to unsteady wake, blowing ratio, and density ratio are only secondary when compared to the dramatic increases in Nusselt numbers only due to film injection over the no film holes case.


Author(s):  
Ali Kosar ◽  
Yoav Peles

An experimental study has been performed on single-phase heat transfer of de-ionized water over a bank of shrouded micro pin fins 243-μm long with hydraulic diameter of 99.5-μm. Heat transfer coefficients and Nusselt numbers have been obtained over effective heat fluxes ranging from 3.8 to 167 W/cm2 and Reynolds numbers from 14 to 112. The results were used to derive the Nusselt numbers and total thermal resistances. It has been found that endwalls effects are significant at low Reynolds numbers and diminish at higher Reynolds numbers.


Author(s):  
Y. S. Muzychka ◽  
M. Ghobadi

Heat transfer in micro and mini-scale ducts and channels is considered. In particular, issues of thermal performance are considered in systems with constant wall temperature at low to moderate Reynolds numbers or small dimensional scales which lead to conditions characteristic of thermally fully developed flows or within the transition region leading to thermally fully developed flows. An analysis of two approaches to representing experimental data is given. One using the traditional Nusselt number and another using the dimensionless mean wall flux. Both approaches offer a number of advantages and disadvantages. In particular, it is shown that while good data can be obtained which agree with predicted heat transfer rates, the same data can be problematic if one desires a Nusselt number. Other issues such as boundary conditions pertaining to measuring thermally developing and fully developed flow Nusselt numbers are also discussed in detail.


Sign in / Sign up

Export Citation Format

Share Document