Theory of Heat Transfer From a Surface Covered With Hair

1990 ◽  
Vol 112 (3) ◽  
pp. 662-667 ◽  
Author(s):  
A. Bejan

This paper describes the fundamental mechanisms of heat transfer through a surface covered with perpendicular hair strands of uniform density. An air flow parallel to the skin seeps through the spaces created between the hair strands. It is shown that the total heat transfer rate from the surface is due to two contributions: (i) the heat conducted through the hair strands, which act as fins, and (ii) the heat convected from the bare portions of the skin. When the air flow is slow enough to conform to the Darcy regime, there exists an optimum hair strand diameter for which the total heat transfer rate is minimum. The optimum diameter increases as the square root of the length swept by the air flow, that is the linear size of the body of the animal covered with hair.

2005 ◽  
Vol 127 (2) ◽  
pp. 179-188 ◽  
Author(s):  
Devashish Shrivastava ◽  
Benjamin McKay ◽  
Robert B. Roemer

Counter-current (vessel–vessel) heat transfer has been postulated as one of the most important heat transfer mechanisms in living systems. Surprisingly, however, the accurate quantification of the vessel–vessel, and vessel–tissue, heat transfer rates has never been performed in the most general and important case of a finite, unheated/heated tissue domain with noninsulated boundary conditions. To quantify these heat transfer rates, an exact analytical expression for the temperature field is derived by solving the 2-D Poisson equation with uniform Dirichlet boundary conditions. The new results obtained using this solution are as follows: first, the vessel–vessel heat transfer rate can be a large fraction of the total heat transfer rate of each vessel, thus quantitatively demonstrating the need to accurately model the vessel–vessel heat transfer for vessels imbedded in tissues. Second, the vessel–vessel heat transfer rate is shown to be independent of the source term; while the heat transfer rates from the vessels to the tissue show a significant dependence on the source term. Third, while many previous studies have assumed that (1) the total heat transfer rate from vessels to tissue is zero, and/or (2) the heat transfer rates from paired vessels (of different sizes and at different temperatures) to tissue are equal to each other the current analysis shows that neither of these conditions is met. The analytical solution approach used to solve this two vessels problem is general and can be extended for the case of “N” arbitrarily located vessels.


Author(s):  
Hsiang-Sheng Huang ◽  
Jung-Chang Wang ◽  
Sih-Li Chen

This article provides an experimental method to study the thermal performance of a heat sink with two pairs (outer and inner pair) of embedded heat pipes. The proposed method can determine the heat transfer rate of the heat pipes under various heating power of the heat source. A comprehensive thermal resistance network of the heat sink is also developed. The network estimates the thermal resistances of the heat sink by applying the thermal performance test result. The results show that the outer and inner pairs of heat pipes carries 21% and 27% of the total heat transfer rate respectively, while 52% of the heating power is dissipated from the base plate to the fins. The dominated thermal resistance of the heat sink is the base to heat pipes resistance which is strongly affected by the thermal performance of the heat pipes. The total thermal resistance of the heat sink shows the lowest value, 0.23°C/W, while the total heat transfer rate of the heat sink is 140W and the heat transfer rate of the outer and inner pairs of heat pipes is 30W and 38 W, respectively.


2013 ◽  
Vol 135 (3) ◽  
Author(s):  
Chunji Yan ◽  
H. B. Ma

A mathematical model predicting heat transfer and film thickness in thin-film region is developed herein. Utilizing dimensionless analysis, analytical solutions have been obtained for heat flux distribution, total heat transfer rate per unit length, location of the maximum heat flux and ratio of conduction thermal resistance to convection thermal resistance in the evaporating film region. These analytical solutions show that the maximum dimensionless heat flux is constant which is independent of the superheat. Maximum total heat transfer rate is determined for a given film region. The ratio of conduction thermal resistance to convection thermal resistance is a function of dimensionless film thickness. This work will lead to a better understanding of heat transfer and fluid flow occurring in the evaporating film region.


2021 ◽  
Vol 7 (1) ◽  
pp. 21-28
Author(s):  
Rahul Kunar ◽  
Dr Sukul Lomash

The heat transfer from surface may in general be enhanced by increasing the heat transfer coefficient between a surface and its surrounding or by increasing heat transfer area of the surface or by both. The main objective of the study and calculate the total heat transfer coefficient. Improve the heat transfer rate by using ANSYS CFD. During the CFD calculations of the flow in internally ribbed tubes. And calculated the temperature distribution and pressure inside the tube by using ansys. The model was created using CatiaV5 and meshed with Ansys, and the flow analysis is done with Ansys 19.2. The results showing that the heat transfer is increased. The enthalpy and temperature increase with flow is advancing when compare with normal boiler tube. In this study the total heat transfer rate of the pipe increase with the increase the rib height. Total heat transfer rate increase up to 7.7kw. The study show that the improvement in furnace heat transfer can be achieved by changing the internal rib design.


2013 ◽  
Vol 284-287 ◽  
pp. 908-914
Author(s):  
King Leung Wong ◽  
Wen Lih Chen ◽  
Li Wen Po

Log mean temperature difference (LMTD) method neglecting the influence of heat radiation is conventionally used to calculate the total heat transfer rate of heat exchangers. From recent investigation of a single-pipe heat exchanger in some practical situations, it is found that the total heat transfer rate error of single-pipe heat exchanger obtained by LMTD method is up to 40% in the situation of oxidized metal heat exchanger with higher surface emissivity located in ambient air with low heat convection coefficient. A log mean heat transfer rate (LMHTR) method considering heat radiation has been developed to calculate the total heat transfer rate of a single-pipe heat exchanger and more accurate results can be achieved. It is also found in the present investigation that LMTD method is also not suitable to apply to non-insulated double-pipe heat exchangers and a more accurate LMHTR method considering heat radiation is developed to obtain the more reasonable results.


Author(s):  
Chunji Yan ◽  
Hongbin Ma

A mathematical model predicting heat transfer and film thickness in thin film region is developed. Utilizing the dimensionless analysis, analytical solutions of the heat flux distribution, the total heat transfer rate per unit width, the location of the maximum heat flux and the ratio of the conduction thermal resistance to the convection thermal resistance in evaporating film region have been obtained. The analytical solutions obtained herein indicate that the maximum dimensionless heat flux is constant which is independent on the superheat. For a given thin film region, its maximum total heat transfer rate is determined. The ratio of the conduction thermal resistance to the convection thermal resistance is a function of dimensionless film thickness. This work will lead to a better understanding of heat transfer and fluid flow occurring in the evaporating film region.


2013 ◽  
Vol 796 ◽  
pp. 623-629
Author(s):  
Kaoru Wakatsuki ◽  
Norimasa Morii ◽  
Yoshio Ogawa ◽  
Hajime Tsuji

During firefighting, within firefighter clothing, underwear and station wear gets heavily wet due to firefighting water and moisture from the body. Water has higher thermal conductivity relative to air and it has been expected that heavily wet condition within the firefighter clothing makes faster skin burns. The objective of this study is how the wet condition within a firefighter clothing makes faster heat transfer from feeling pain and to being 2nd degree of skin burns relative to the dry condition in case of routine firefighting operation in a building (up to 20 kW/m2). Aramid station wear and cotton underwear, generally used by a Japanese firefighter, have been selected and cut 0.15 m x 0.15 m to attach an ISO 9151 copper sensor. A cone shape electric heater, which produces 12 kW/m2 to 20 kW/m2, was used to heat the fabrics. Scenario of fabrics are that (1) wet station wear and dry underwear, (2) wet station and wet underwear, (3) dry station wear and wet underwear, and (4) dry station wear and dry underwear. Evaluation method was by a heat transfer index (HTI) by ISO 9151. The time to rise temperature of 12 and 24 °C (HTI12 and HTI24), and heat transfer rate (dT/dt) were investigated for above four scenarios. The result shows that there was significant impact by condition of station wear, but little impact by underwear. In heat transfer rate (dT/dt) analysis, for the situation of feeling pain to the 2nd degree of skin burns (from HTI12 to HTI24), heat transfer rate was about 50% higher relative to the dry station wear condition. This result indicates that it is possible to be 2nd degree of skin burns easily as soon as a firefighter feels the pain, if he/she wears wet station wear.


2015 ◽  
Vol 32 (8) ◽  
pp. 2419-2442 ◽  
Author(s):  
S. A. Moshizi

Purpose – The purpose of this paper is to focus on convective heat and mass transfer characteristics of Cu-water nanofluid inside a porous microchannel in the presence of a uniform magnetic field. The walls of the microchannel are subjected to constant asymmetric heat fluxes and also the first order catalytic reaction. To represent the non-equilibrium region near the surfaces, the Navier’s slip condition is considered at the surfaces because of the non-adherence of the fluid-solid interface and the microscopic roughness in microchannels. Design/methodology/approach – Employing the Brinkman model for the flow in the porous medium and the “clear fluid compatible” model as a viscous dissipation model, the conservative partial differential equations have been transformed into a system of ordinary ones via the similarity variables. Closed form exact solutions are obtained analytically based on dimensionless parameters of velocity, temperature and species concentration. Findings – Results show that the addition of Cu-nanoparticles to the fluid has a significant influence on decreasing concentration, temperature distribution at the both walls and velocity profile along the microchannel. In addition, total heat transfer in microchannel increases as nanoparticles add to the fluid. Slip parameter and Hartmann number have the decreasing effects on concentration and temperature distributions. Slip parameter leads to increase velocity profiles, while Hartmann number has an opposite trend in velocity profiles. These two parameters increase the total heat transfer rate significantly. Originality/value – In the present study, a comprehensive analytical solution has been obtained for convective heat and mass transfer characteristics of Cu-water nanofluid inside a porous microchannel in the presence of a uniform magnetic field. Finally, the effects of several parameters such as Darcy number, nanoparticle volume fraction, slip parameter, Hartmann number, Brinkman number, asymmetric heat flux parameter, Soret and Damkohler numbers on total heat transfer rate and fluid flow profiles are studied in more detail. To the best of author’s knowledge, no study has been conducted to this subject and the results are original.