A Comparison of Two Test Methods for Determining Transfer Function Coefficients for a Wall Using a Calibrated Hot Box

1990 ◽  
Vol 112 (1) ◽  
pp. 35-42 ◽  
Author(s):  
D. M. Burch ◽  
B. A. Licitra ◽  
R. R. Zarr

This paper experimentally verifies and compares two dynamic test methods for a calibrated hot box to characterize the transient thermal performance of complex walls. In these methods, a wall specimen is sandwiched between the two conditioning chambers of a calibrated hot box. The exterior surface of the wall specimen is subjected to a time-varying excitation function in air temperature. At the interior surface, the air temperature is maintained steady, and the heat transfer response is measured. Conduction transfer function coefficients that relate the measured heat transfer response to the excitation function are derived. The two dynamic test methods were applied to an insulated hollow concrete block wall that contained significant thermal bridges and lateral heat flows. Empirical transfer function coefficients derived by the test methods predicted with good agreement the heat transfer response of this wall specimen when its exterior surface was subjected to excitation functions that differed markedly from those used to derive the coefficients.

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3955
Author(s):  
Yonghan Ahn ◽  
Hanbyeol Jang ◽  
Junghyon Mun

The purpose of this study is to compare the load calculation results by a model using the air changes per hour (ACH) method and a model using an airflow network (AFN) and to ascertain what causes the difference between the two models. In the basic case study, the difference in the heat transfer distribution of the model in the interior space was investigated. The most significant difference between the two models is the heat transfer that results from infiltration. Parameter analysis was performed to investigate the relationship between the difference and the environmental variables. The result shows that the greater the difference is between the air temperature inside the balcony and the outdoor air temperature, and the greater the air flows from the balcony to the residential area, and the greater the heating and cooling load difference occurs. The analysis using the actual weather files of five domestic cities in South Korea rather than a virtual case shows that the differences are not so obvious when the wind blows at a constant speed throughout the year, but are dominant when the wind does not blow during the night and is stronger alongside the occurrence of sunlight during the day.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2315
Author(s):  
Christian Meltebrink ◽  
Tom Ströer ◽  
Benjamin Wegmann ◽  
Cornelia Weltzien ◽  
Arno Ruckelshausen

As an essential part for the development of autonomous agricultural robotics, the functional safety of autonomous agricultural machines is largely based on the functionality and robustness of non-contact sensor systems for human protection. This article presents a new step in the development of autonomous agricultural machine with a concept and the realization of a novel test method using a dynamic test stand on an agricultural farm in outdoor areas. With this test method, commercially available sensor systems are tested in a long-term test around the clock for 365 days a year and 24 h a day on a dynamic test stand in continuous outdoor use. A test over a longer period of time is needed to test as much as possible all occurring environmental conditions. This test is determined by the naturally occurring environmental conditions. This fact corresponds to the reality of unpredictable/determinable environmental conditions in the field and makes the test method and test stand so unique. The focus of the developed test methods is on creating own real environment detection areas (REDAs) for each sensor system, which can be used to compare and evaluate the autonomous human detection of the sensor systems for the functional safety of autonomous agricultural robots with a humanoid test target. Sensor manufacturers from industry and the automotive sector provide their sensor systems to have their sensors tested in cooperation with the TÜV.


2015 ◽  
Vol 787 ◽  
pp. 238-242 ◽  
Author(s):  
R. Pachaiyappan ◽  
J. Dasa Prakash

Air pre-heater and economizer are heat transfer surfaces in which air temperature and water temperature are raised by transferring heat from other media such as flue gas. Hot air is necessary for rapid combustion in the furnace and also for drying coal in milling plants. So an essential boiler accessory which serves this purpose is air pre-heater. The air pre-heater is not essential for operation of steam generator, but they are used where a study of cost indicates that money can be saved or efficient combustion can be obtained by their use. The decision for its adoption can be made when the financial advantages is weighed against the capital cost of heater. The efficiency of the boiler increases with the increase in the temperature of the combustion air used in the furnace. This is achieved by the increased temperature of the flue gas in the air preheater and economizer zone. This paper deals with the different ways to obtain the maximum heat from the flue gas travelling through the air preheater and the economizer zone to improve the boiler efficiency.


1975 ◽  
Vol 39 (1) ◽  
pp. 93-102 ◽  
Author(s):  
R. M. Smith ◽  
J. M. Hanna

Fourteen male subjects with unweighted mean skinfolds (MSF) of 10.23 mm underwent several 3-h exposures to cold water and air of similar velocities in order to compare by indirect calorimetry the rate of heat loss in water and air. Measurements of heat loss (excluding the head) at each air temperature (Ta = 25, 20, 10 degrees C) and water temperature (Tw = 29–33 degrees C) were used in a linear approximation of overall heat transfer from body core (Tre) to air or water. We found the lower critical air and water temperatures to fall as a negative linear function of MSF. The slope of these lines was not significantly different in air and water with a mean of minus 0.237 degrees C/mm MSF. Overall heat conductance was 3.34 times greater in water. However, this value was not fixed but varied as an inverse curvilinear function of MSF. Thus, equivalent water-air temperatures also varied as a function of MSF. Between limits of 100–250% of resting heat loss the followingrelationships between MSF and equivalent water-air temperatures were found (see article).