Rotordynamic Evaluation of an Advanced Multisqueeze Film Damper—Imbalance Response and Blade-Loss Simulation

1993 ◽  
Vol 115 (2) ◽  
pp. 347-352 ◽  
Author(s):  
J. F. Walton ◽  
H. Heshmat

In this paper results of rotordynamic response and transient tests of a novel, high load squeeze film damper design are presented. The spiral foil multisqueeze film damper has been previously shown to provide two to fourfold or larger increases in damping levels without resorting to significantly decreased damper clearances or increased lengths. By operating with a total clearance of approximately twice conventional designs, the nonlinearities associated with high-eccentricity operation are avoided. Rotordynamic tests with a dual squeeze film configuration were completed. As a part of the overall testing program, a flexible rotor system was subjected to high steady-state imbalance levels and transient simulated blade-loss events for up to 0.254 mm (0.01 in.) mass c. g. offset or 180 g-cm (2.5 oz-in.) imbalance. The spiral foil multisqueeze film damper demonstrated that the steady-state imbalance and simulated blade-loss transient response of a flexible rotor operating above its first bending critical speed could be readily controlled. Rotor system imbalance sensitivity and logarithmic decrement are presented showing the characteristics of the system with the damper installed. The ability to accommodate high steady-state and transient imbalance conditions make this damper well suited to a wide range of rotating machinery, including aircraft gas turbine engines.

Author(s):  
J. F. Walton ◽  
H. Heshmat

In this paper results of rotordynamic response and transient tests of a novel, high load squeeze film damper design, are presented. The spiral foil multi-squeeze film damper has been previously shown to provide two to four fold or larger increases in damping levels without resorting to significantly decreased damper clearances or increased lengths. By operating with a total clearance of approximately twice conventional designs, the non-linearities associated with high eccentricity operation are avoided. Rotordynamic tests with a dual squeeze film configuration were completed. As a part of the overall testing program, a flexible rotor system was subjected to high steady state imbalance levels and transient simulated bladeloss events for up to 0.254 mm (0.01 in) mass c.g offset or 180 gm-cm (2.5 oz-in) imbalance. The spiral foil multi-squeeze film damper demonstrated that the steady state imbalance and simulated bladeloss transient response of a flexible rotor operating above its first bending critical speed could be readily controlled. Rotor system imbalance sensitivity and logarithmic decrement are presented showing the characteristics of the system with the damper installed. The ability to accommodate high steady state and transient imbalance conditions make this damper well suited to a wide range of rotating machinery, including aircraft gas turbine engines.


1993 ◽  
Vol 115 (2) ◽  
pp. 366-371 ◽  
Author(s):  
J. Walton ◽  
M. Martin

In this paper, results of experimental rotordynamic evaluations of a novel, high load chambered porous damper design are presented. The chambered porous damper concept was evaluated for gas turbine engine application since this concept avoids the nonlinearities associated with high-eccentricity operation of conventional squeeze film dampers. The rotordynamic testing was conducted under large steady-state imbalance and simulated transient bladeloss conditions for up to 0.254 mm (0.01 in.) mass c.g offset or 180 g-cm (2.5 oz-in.) imbalance. The chambered porous damper demonstrated that the steady-state imbalance and simulated blade-loss transient response of a flexible rotor operating above its first bneding critical speed could be readily controlled. Rotor system imbalance sensitivity and logarithmic decrement are presented showing the characteristics of the system with the damper installed. The ability to accommodate high steady-state and transient imbalance conditions makes this damper well suited to a wide range of rotating machinery, including aircraft gas turbine engines.


Author(s):  
J. Walton ◽  
M. Martin

In this paper, results of experimental rotordynamic evaluations of a novel, high load chambered porous damper design, are presented. The chambered porous damper concept was evaluated for gas turbine engine application since this concept avoids the non-linearities associated with high eccentricity operation of conventional squeeze film dampers. The rotordynamic testing was conducted under large steady state imbalance and simulated transient bladeloss conditions for up to 0.254 mm (0.01 in) mass c.g offset or 180 gm-cm (2.5 oz-in) imbalance. The chambered porous damper demonstrated that the steady state imbalance and simulated bladeloss transient response of a flexible rotor operating above its first bending critical speed could be readily controlled. Rotor system imbalance sensitivity and logarithmic decrement are presented showing the characteristics of the system with the damper installed. The ability to accommodate high steady state and transient imbalance conditions make this damper well suited to a wide range of rotating machinery, including aircraft gas turbine engines.


1993 ◽  
Vol 115 (2) ◽  
pp. 360-365 ◽  
Author(s):  
J. Tecza ◽  
J. Walton

In this paper a novel, high-load chambered porous damper design, supporting analysis, and experimental results are presented. It was demonstrated that significant damping can be generated from the viscous discharge losses of capillary tubes arranged in chambered segments with large radial clearances and that the resulting damping is predictable and fairly constant with speed and eccentricity ratio. This design avoids the nonlinearities associated with high-eccentricity operation of conventional squeeze film dampers. Controlled orbit tests with a porous chambered configuration were completed and favorably compared with theoretical predictions. The ability to accommodate high steady-state and transient imbalance conditions makes this damper well suited to a wide range of rotating machinery, including aircraft gas turbine engines.


Author(s):  
J. Tecza ◽  
J. Walton

In this paper a novel, high load chambered porous damper design, supporting analysis, and experimental results are presented. It was demonstrated that significant damping can be generated from the viscous discharge losses of capillary tubes arranged in chambered segments with large radial clearances and that the resulting damping is predictable and fairly constant with speed and eccentricity ratio. This design avoids the non-linearities associated with high eccentricity operation of conventional squeeze film dampers. Controlled orbit tests with a porous chambered configuration were completed and favorably compared with theoretical predictions. The ability to accommodate high steady state and transient imbalance conditions make this damper well suited to a wide range of rotating machinery, including aircraft gas turbine engines.


2021 ◽  
Author(s):  
Ying Cui ◽  
Yuxi Huang ◽  
Guogang Yang ◽  
Yongliang Wang ◽  
Han Zhang

Abstract A nonlinear multi-degree-of-freedom dynamic model of a coupled dual-rotor system with an intershaft bearing and uncentralized squeeze film damper is established by using finite element method. Based on the model, the critical speed characteristic diagram and vibration modes of the system were calculated. The steady-state unbalance response is obtained by using Newmark-β algorithm. The numerical results show the effect of SFD position in the dual-rotor system on response amplitude. It is found that with the decrease of radial clearance and the increase of length-diameter ratio and lubricating oil viscosity, the damping effect of SFD is enhanced and the bistable state phenomenon can be suppressed. The transient response of the system in case of sudden unbalance occurring at the fan was simulated by applying a step function. It is demonstrated that the SFD can effectively reduce the duration and maximum amplitude of the transient process, but at certain speeds, the SFD will increase the amplitude after the system returns to steady state, the damping effect on the transient response is also enhanced with the increase of length-diameter and the decrease of radial clearance, and with the increase of the sudden unbalance value, the response is more likely to stabilized at the high amplitude state of the bistable state.


Author(s):  
Shin Morishita ◽  
Jun’ichi Mitsui

Abstract A notable characteristic of Electro-Rheological (ER) fluid is the variation of its apparent viscosity with the application of an electric field. The application of this characteristic to the performance of squeeze film damper of a flexible rotor is investigated in this paper. It is shown experimentally that by controlling the supporting damping capacity continuously, rotor vibration can be reduced remarkably in a wide range of rotating speed. Moreover, the study indicates experimentally that there exists an optimum supporting damping for every vibration mode.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Wei Yan ◽  
Lidong He ◽  
Zhe Deng ◽  
Xingyun Jia

Abstract As a novel structural damper, the unique structural characteristics of the integral squeeze film damper (ISFD) solve the nonlinear problem of the traditional squeeze film damper (SFD), and it has good linear damping characteristics. In this research, the experimental studies of ISFD vibration reduction performance are carried out for various working conditions of unbalanced rotors. Two ball bearing-rotor system test rigs are built based on ISFD: a rigid rotor test rig and a flexible rotor test rig. When the rotational speed of rigid rotor is 1500 rpm, ISFD can reduce the amplitude of the rotor by 41.79%. Under different unbalance conditions, ISFD can effectively improve the different degrees of unbalanced faults in the rotor system, reduce the amplitude by 43.21%, and reduce the sensitivity of the rotor to unbalance. Under different rotational speed conditions, ISFD can effectively suppress the unbalanced vibration of rigid rotor, and the amplitude can be reduced by 53.51%. In the experiment of the unbalanced response of the flexible rotor, it is found that ISFD can improve the damping of the rotor system, effectively suppress the resonance of the rotor at the critical speed, and the amplitude at the first-order critical speed can be reduced by 31.72%.


Sign in / Sign up

Export Citation Format

Share Document