scholarly journals Endwall Heat Transfer Measurements in a Transonic Turbine Cascade

1998 ◽  
Vol 120 (2) ◽  
pp. 305-313 ◽  
Author(s):  
P. W. Giel ◽  
D. R. Thurman ◽  
G. J. Van Fossen ◽  
S. A. Hippensteele ◽  
R. J. Boyle

Turbine blade endwall heat transfer measurements are presented for a range of Reynolds and Mach numbers. Data were obtained for Reynolds numbers based on inlet conditions of 0.5 and 1.0 × 106, for isentropic exit Mach numbers of 1.0 and 1.3, and for free-stream turbulence intensities of 0.25 and 7.0 percent. Tests were conducted in a linear cascade at the NASA Lewis Transonic Turbine Blade Cascade Facility. The test article was a turbine rotor with 136 deg of turning and an axial chord of 12.7 cm. The large scale allowed for very detailed measurements of both flow field and surface phenomena. The intent of the work is to provide benchmark quality data for CFD code and model verification. The flow field in the cascade is highly three dimensional as a result of thick boundary layers at the test section inlet. Endwall heat transfer data were obtained using a steady-state liquid crystal technique.

Author(s):  
P. W. Giel ◽  
D. R. Thurman ◽  
G. J. Van Fossen ◽  
S. A. Hippensteele ◽  
R. J. Boyle

Turbine blade endwall heat transfer measurements are given for a range of Reynolds and Mach numbers. Data were obtained for Reynolds numbers based on inlet conditions of 0.5 and 1.0 × 106, for isentropic exit Mach numbers of 1.0 and 1.3, and for freestream turbulence intensities of 0.25% and 7.0%. Tests were conducted in a linear cascade at the NASA Lewis Transonic Turbine Blade Cascade Facility. The test article was a turbine rotor with 136° of turning and an axial chord of 12.7 cm. The large scale allowed for very detailed measurements of both flow field and surface phenomena. The intent of the work is to provide benchmark quality data for CFD code and model verification. The flow field in the cascade is highly three-dimensional as a result of thick boundary layers at the test section inlet. Endwall heat transfer data were obtained using a steady-state liquid crystal technique.


1986 ◽  
Vol 108 (2) ◽  
pp. 269-274
Author(s):  
R. G. Williamson ◽  
S. H. Moustapha ◽  
J. P. Huot

Two nozzle designs, involving the same low aspect ratio, high turning angle vanes, and differing in outer wall contour, were tested over a range of exit Mach numbers up to supersonic values. The experiments were conducted on a large-scale, full annular configuration with and without a representative rotor downstream. Nozzle performance was found to be significantly affected by rotor operation, the influence depending on the detailed characteristics of the nozzle flow field, as well as on the design and operation of the rotor itself. It is suggested that performance evaluation of low aspect ratio nozzles of high turning angle may require appropriate testing with a rotor.


1992 ◽  
Vol 114 (4) ◽  
pp. 847-857 ◽  
Author(s):  
J. H. Wagner ◽  
B. V. Johnson ◽  
R. A. Graziani ◽  
F. C. Yeh

Experiments were conducted to determine the effects of buoyancy and Coriolis forces on heat transfer in turbine blade internal coolant passages. The experiments were conducted with a large-scale, multipass, heat transfer model with both radially inward and outward flow. Trip strips on the leading and trailing surfaces of the radial coolant passages were used to produce the rough walls. An analysis of the governing flow equations showed that four parameters influence the heat transfer in rotating passages: coolant-to-wall temperature ratio, Rossby number, Reynolds number, and radius-to-passage hydraulic diameter ratio. The first three of these four parameters were varied over ranges that are typical of advanced gas turbine engine operating conditions. Results were correlated and compared to previous results from stationary and rotating similar models with trip strips. The heat transfer coefficients on surfaces, where the heat transfer increased with rotation and buoyancy, varied by as much as a factor of four. Maximum values of the heat transfer coefficients with high rotation were only slightly above the highest levels obtained with the smooth wall model. The heat transfer coefficients on surfaces where the heat transfer decreased with rotation, varied by as much as a factor of three due to rotation and buoyancy. It was concluded that both Coriolis and buoyancy effects must be considered in turbine blade cooling designs with trip strips and that the effects of rotation were markedly different depending upon the flow direction.


2010 ◽  
Vol 133 (1) ◽  
Author(s):  
J. S. Carullo ◽  
S. Nasir ◽  
R. D. Cress ◽  
W. F. Ng ◽  
K. A. Thole ◽  
...  

This paper experimentally investigates the effect of high freestream turbulence intensity, turbulence length scale, and exit Reynolds number on the surface heat transfer distribution of a turbine blade at realistic engine Mach numbers. Passive turbulence grids were used to generate freestream turbulence levels of 2%, 12%, and 14% at the cascade inlet. The turbulence grids produced length scales normalized by the blade pitches of 0.02, 0.26, and 0.41, respectively. Surface heat transfer measurements were made at the midspan of the blade using thin film gauges. Experiments were performed at the exit Mach numbers of 0.55, 0.78, and 1.03, which represent flow conditions below, near, and above nominal conditions. The exit Mach numbers tested correspond to exit Reynolds numbers of 6×105, 8×105, and 11×105, based on true chord. The experimental results showed that the high freestream turbulence augmented the heat transfer on both the pressure and suction sides of the blade as compared with the low freestream turbulence case. At nominal conditions, exit Mach 0.78, average heat transfer augmentations of 23% and 35% were observed on the pressure side and suction side of the blade, respectively.


1992 ◽  
Vol 114 (1) ◽  
pp. 147-154 ◽  
Author(s):  
T. Arts ◽  
M. Lambert de Rouvroit

This contribution deals with an experimental aero-thermal investigation around a highly loaded transonic turbine nozzle guide vane mounted in a linear cascade arrangement. The measurements were performed in the von Karman Institute short duration Isentropic Light Piston Compression Tube facility allowing a correct simulation of Mach and Reynolds numbers as well as of the gas to wall temperature ratio compared to the values currently observed in modern aero engines. The experimental program consisted of flow periodicity checks by means of wall static pressure measurements and Schlieren flow visualizations, blade velocity distribution measurements by means of static pressure tappings, blade convective heat transfer measurements by means of platinum thin films, downstream loss coefficient and exit flow angle determinations by using a new fast traversing mechanism, and free-stream turbulence intensity and spectrum measurements. These different measurements were performed for several combinations of the free-stream flow parameters looking at the relative effects on the aerodynamic blade performance and blade convective heat transfer of Mach number, Reynolds number, and free-stream turbulence intensity.


Author(s):  
Carlos Arroyo Osso ◽  
T. Gunnar Johansson ◽  
Fredrik Wallin

In most designs of two-spool turbofan engines, intermediate turbine duct (ITD’s) are used to connect the high-pressure turbine (HPT) with the low-pressure turbine (LPT). Demands for more efficient engines with reduced emissions require more “aggressive ducts”, ducts which provide both a higher radial offset and a larger area ratio in the shortest possible length, while maintaining low pressure losses and avoiding non-uniformities in the outlet flow that might affect the performance of the downstream LPT. The work presented in this paper is part of a more comprehensive experimental and computational study of the flowfield and the heat transfer in an aggressive ITD. The main objectives of the study were to obtain an understanding of the mechanisms governing the heat transfer in ITD’s and to obtain high quality experimental data for the improvement of the CFD-based design tools. This paper consists of two parts. The first one, this one, presents and discusses the results of the experimental study. In the second part, a comparison between the experimental results and a numerical analysis is presented. The duct studied was a state-of-the-art “aggressive” design with nine thick non-turning structural struts. It was tested in a large-scale low-speed experimental facility with a single-stage HPT. In this paper measurements of the steady convective heat transfer coefficient (HTC) distribution on both endwalls and on the strut for the duct design inlet conditions are presented. The heat transfer measurement technique used is based on infrared-thermography. Part of the results of the flow measurements is also included.


2018 ◽  
Vol 2018 ◽  
pp. 1-9
Author(s):  
Fangyuan Lou ◽  
John Charles Fabian ◽  
Nicole Leanne Key

This paper investigates the aerodynamics of a transonic impeller using static pressure measurements. The impeller is a high-speed, high-pressure-ratio wheel used in small gas turbine engines. The experiment was conducted on the single stage centrifugal compressor facility in the compressor research laboratory at Purdue University. Data were acquired from choke to near-surge at four different corrected speeds (Nc) from 80% to 100% design speed, which covers both subsonic and supersonic inlet conditions. Details of the impeller flow field are discussed using data acquired from both steady and time-resolved static pressure measurements along the impeller shroud. The flow field is compared at different loading conditions, from subsonic to supersonic inlet conditions. The impeller performance was strongly dependent on the inducer, where the majority of relative diffusion occurs. The inducer diffuses flow more efficiently for inlet tip relative Mach numbers close to unity, and the performance diminishes at other Mach numbers. Shock waves emerging upstream of the impeller leading edge were observed from 90% to 100% corrected speed, and they move towards the impeller trailing edge as the inlet tip relative Mach number increases. There is no shock wave present in the inducer at 80% corrected speed. However, a high-loss region near the inducer throat was observed at 80% corrected speed resulting in a lower impeller efficiency at subsonic inlet conditions.


1997 ◽  
Vol 119 (3) ◽  
pp. 594-600 ◽  
Author(s):  
S. V. Ekkad ◽  
A. B. Mehendale ◽  
J. C. Han ◽  
C. P. Lee

Experiments were performed to study the combined effect of grid turbulence and unsteady wake on film effectiveness and heat transfer coefficient of a turbine blade model. Tests were done on a five-blade linear cascade at the chord Reynolds number of 3.0 × 105 at cascade inlet. Several combinations of turbulence grids, their locations, and unsteady wake strengths were used to generate various upstream turbulence conditions. The test blade had three rows of film holes in the leading edge region and two rows each on the pressure and suction surfaces. Air and CO2 were used as injectants. Results show that Nusselt numbers for a blade with film injection are much higher than that without film holes. An increase in mainstream turbulence level causes an increase in Nusselt numbers and a decrease in film effectiveness over most of the blade surface, for both density injectants, and at all blowing ratios. A free-stream turbulence superimposed on an unsteady wake significantly affects Nusselt numbers and film effectiveness compared with only an unsteady wake condition.