Temperature Response of Heat Transport in a Micro Heat Pipe

1999 ◽  
Vol 121 (2) ◽  
pp. 438-445 ◽  
Author(s):  
G. P. Peterson ◽  
H. B. Ma

A detailed mathematical model for predicting the heat transport capability and temperature gradients that contribute to the overall axial temperature drop as a function of heat transfer in a micro heat pipe has been developed. The model utilizes a third-order ordinary differential equation, which governs the fluid flow and heat transfer in the evaporating thin film region; an analytical solution for the two-dimension heat conduction equation, which governs the macro evaporating film region in the triangular corners; the effects of the vapor flow on the liquid flow in the micro heat pipe; the flow and condensation of the thin film caused by the surface tension in the condenser; and the capillary flow along the axial direction of the micro heat pipe. With this model, the temperature distribution along the axial direction of the heat pipe and the effect on the heat transfer can be predicted. In order to verify the model presented here, an experimental investigation was also conducted and a comparison with experimental data made. This comparison indicated excellent correlation between the analytical model and experimental results, and as a result, the analysis provides a better understanding of the heat transfer capability and temperature variations occurring in micro heat pipes.

2008 ◽  
Vol 130 (5) ◽  
Author(s):  
A. J. Jiao ◽  
H. B. Ma ◽  
J. K. Critser

A mathematical model predicting the heat transport capability in a miniature flat heat pipe (FHP) with a wired wick structure was developed to analytically determine its maximum heat transport rate including the capillary limit. The effects of gravity on the profile of the thin-film-evaporation region and the distribution of the heat flux along a curved surface were investigated. The heat transfer characteristics of the thin-film evaporation on the curved surface were also analyzed and compared with that on a flat surface. Combining the analysis on the thin-film-condensation heat transfer in the condenser, the model can be used to predict the total temperature drop between the evaporator and condenser in the FHP. In order to verify the model, an experimental investigation was conducted. The theoretical results predicted by the model agree well with the experimental data for the heat transfer process occurring in the FHP with the wired wick structure. Results of the investigation will assist in the optimum design of the curved-surface wicks to enlarge the thin-film-evaporation region and a better understanding of heat transfer mechanisms in heat pipes.


2009 ◽  
Vol 131 (2) ◽  
Author(s):  
K. N. Shukla

An analytical expression for the heat transport capability of micro heat pipe is derived. The vapor continuum limitation has been considered in deriving the heat transport capability of a micro heat pipe. As the micro heat pipe uses sharp-cornered square, triangular, or other polygonal channels that can serve as capillary arteries, its transport capability depends on the capillary limit. It has been shown that the operating limit of the micro heat pipe depends on the vapor continuum limitation, capillary limit, and the gravity.


Author(s):  
Kyu Hyung Do ◽  
Sung Jin Kim ◽  
Gunn Hwang

Heat transfer and fluid flow characteristics in a micro heat pipe with curved triangular grooves are investigated using numerical and experimental methods. In the numerical part, a one-dimensional mathematical model for micro heat pipe with curved triangular grooves is developed and solved to obtain the maximum heat transport rate, the capillary radius distribution, the liquid and the vapor pressure distributions along the axial direction of the micro heat pipe under the steady-state condition. In particular, the modified Shah method is applied to calculate the pressure drop induced by the liquid-vapor interfacial shear stress. Experiments are conducted to validate the numerical model. In the experiments, the micro heat pipe with 0.56 mm in hydraulic diameter and 50 mm in length is tested. The experimental results for the maximum heat transport rate agree well with those of the numerical investigations. Finally, thermal optimization of the micro heat pipe with curved triangular grooves is performed using the numerical model.


2014 ◽  
Vol 609-610 ◽  
pp. 1526-1531 ◽  
Author(s):  
Yan Xia Yang ◽  
Xiao Dong Wang ◽  
Yi Luo ◽  
Liang Liang Zou

To study the heat transfer performance of micro heat pipe, theoretical analysis of flat plate micro heat pipe with trapezoid cross section are presented in this paper. A one-dimensional stationary mathematical model for micro heat pipe grooved capillary flow using finite volume method (FVM) was established. The micro heat pipe had vapor space connect with each other and the influences of shear stress between vapor and fluid in the working process were described in the model which made the model more precisely. The axial variation of working fluid distribution in the heat pipe, pressure difference between vapor and liquid, and velocity of vapor and liquid were analyzed. In addition, the maximum heat transport capacity of micro heat pipe was calculated. The simulation results showed good agreement with the experiment results, and it could predict the heat transfer performance accurately, which was useful to micro heat pipe structural design.


Author(s):  
Fun Liang Chang ◽  
Yew Mun Hung

Purpose This paper aims to investigate the coupled effects of electrohydrodynamic and gravity forces on the circulation effectiveness of working fluid in an inclined micro heat pipe driven by electroosmotic flow. The effects of the three competing forces, namely, the capillary, the gravitational and the electrohydrodyanamic forces, on the circulation effectiveness of a micro heat pipe are compared and delineated. Design/methodology/approach The numerical model is developed based on the conservations of mass, momentum and energy with the incorporation of the Young–Laplace equation for electroosmotic flow in an inclined micro heat pipe incorporating the gravity effects. Findings By inducing electroosmotic flow in a micro heat pipe, a significant increase in heat transport capacity can be attained at a reasonably low applied voltage, leading to a small temperature drop and a high thermal conductance. However, the favorably applied gravity forces pull the liquid toward the evaporator section where the onset of flooding occurs within the condenser section, generating a throat that shrinks the vapor flow passage and may lead to a complete failure on the operation of micro heat pipe. Therefore, the balance between the electrohydrodyanamic and the gravitational forces is of vital importance. Originality/value This study provides a detailed insight into the gravitational and electroosmotic effects on the thermal performance of an inclined micro heat pipe driven by electroosmotic flow and paves the way for the feasible practical application of electrohydrodynamic forces in a micro-scale two-phase cooling device.


Author(s):  
D. Sugumar ◽  
Kek Kiong Tio

A micro heat pipe will operate effectively by achieving its maximum possible heat transport capacity only if it is to operate at a specific temperature, i.e., design temperature. In reality, micro heat pipe’s may be required to operate at temperatures different from the design temperature. In this study, the heat transport capacity of an equilateral triangle micro heat pipe is investigated. The micro heat pipe is filled optimally with working fluid for a specific design temperature and operated at different operating temperatures. For this purpose, water, pentane and acetone was selected as the working fluids. From the numerical results obtained, it shows that the optimal charge level of the micro heat pipe is dependent on the operating temperature. Furthermore, the results also shows that if the micro heat pipe is to be operated at temperatures other than its design temperature, its heat transport capacity is limited by the occurrence of flooding at the condenser section or dryout at the evaporator section, depending on the operating temperature and type of working fluid. It is observed that when the micro heat pipe is operated at a higher temperature than its design temperature, the heat transport capacity increases but limited by the onset of dryout at the evaporator section. However, the heat transport capacity decreases if it is to be operated at lower temperatures than its design temperature due to the occurrence of flooding at condenser end. From the results obtained, we can conclude that the performance of a micro heat pipe is decreased if it is to be operated at temperatures other than its design temperature.


Author(s):  
Nannan Zhao ◽  
Benwei Fu ◽  
Hongbin Ma ◽  
Fengmin Su

The heat transport capability in an oscillating heat pipe (OHP) significantly depends on the oscillating frequency. An external frequency directly affects the natural frequency in the system. In this investigation, the ultrasound sound effect on the heat transport capability in an OHP was conducted with focus on the ultrasonic frequency effect on the oscillating motion and heat transfer capacity in an OHP. The ultrasonic sound was applied to the evaporating section of the OHP by using the electrically-controlled piezoelectric ceramics. The heat pipe was tested with or without the ultrasonic sound with different frequencies. In addition, the effects of operating temperature, heat load from 25 W to 150 W were investigated. The experimental results demonstrate that the heat transfer capacity enhancement of the OHP depends on the frequency of the ultrasound field, and there exists an optimum combination of the frequencies which will lead to the largest enhancement of the heat transfer capacity of the OHP.


2020 ◽  
Vol 21 (3) ◽  
pp. 309
Author(s):  
Maryam Fallah Abbasi ◽  
Hossein Shokouhmand ◽  
Morteza Khayat

Electronic industries have always been trying to improve the efficiency of electronic devices with small dimensions through thermal management of this equipment, thus increasing the use of small thermal sinks. In this study micro heat pipes with triangular and square cross sections have been manufactured and tested. One of the main objectives is to obtain an understanding of micro heat pipes and their role in energy transmission with electrical double layer (EDL). Micro heat pipes are highly efficient heat transfer devices, which use the continuous evaporation/condensation of a suitable working fluid for two-phase heat transport in a closed system. Since the latent heat of vaporization is very large, heat pipes transport heat at small temperature difference, with high rates. Because of variety of advantage features these devices have found a number of applications both in space and terrestrial technologies. The theory of operation micro heat pipes with EDL is described and the micro heat pipe has been studied. The temperature distribution have achieved through five thermocouples installed on the body. Water and different solution mixture of water and ethanol have used to investigate effect of the electric double layer heat transfer. It was noticed that the electric double layer of ionized fluid has caused reduction of heat transfer.


Sign in / Sign up

Export Citation Format