Enhanced Heat Transfer Rate Measured for Natural Convection in Liquid Gallium in a Cubical Enclosure Under a Static Magnetic Field

1998 ◽  
Vol 120 (4) ◽  
pp. 1027-1032 ◽  
Author(s):  
Toshio Tagawa ◽  
Hiroyuki Ozoe

The heat transfer rate of natural convection in liquid gallium in a cubical enclosure was measured experimentally under an external magnetic field applied horizontally and parallel to the vertical heated wall and the opposing cooled wall and the opposing cooled wall of the enclosure. One vertical wall was heated with an electric heater and the opposing wall was cooled isothermally with running water. Experiments were conducted in the range of modified Rayleigh number from 1.85 × 106 to 4.76 × 106 and of Hartmann number from 0 to 573. The average Nusselt number was measured and found to increase when a moderate magnetic field was applied, but to decrease under a stronger magnetic field. This result means that the heat transfer rate has a maximum value at a certain moderate magnetic field, which supports our previous numerical analyses.

Author(s):  
Gustavo Gutierrez ◽  
Ezequiel Medici

The interaction between magnetic fields and convection is an interesting phenomenon because of its many important engineering applications. Due to natural convection motion the electric conductive fluid in a magnetic field experiences a Lorenz force and its effect is usually to reduce the flow velocities. A magnetic field can be used to control the flow field and increase or reduce the heat transfer rate. In this paper, the effect of a magnetic field in a natural convection flow of an electrically conducting fluid in a rectangular cavity is studied numerically. The two side walls of the cavity are maintained at two different constant temperatures while the upper wall and the lower wall are completely insulated. The coupling of the Navier-Stokes equations with the Maxwell equations is discussed with the assumptions and main simplifications assumed in typical problems of magnetohydrodynamics. The nonlinear Lorenz force generates a rich variety of flow patterns depending on the values of the Grashof and Hartmann numbers. Numerical simulations are carried out for different Grashof and Hartmann numbers. The effect of the magnetic field on the Nusselt number is discussed as well as how convection can be suppressed for certain values of the Hartmann number under appropriate direction of the magnetic field.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Surabhi Nishad ◽  
Sapna Jain ◽  
Rama Bhargava

Purpose This paper aims to study the flow and heat transfer inside a wavy enclosure filled with Cu-water nanofluid under magnetic field effect by parallel implemented meshfree approach. Design/methodology/approach The simulation has been carried out for a two-dimensional model with steady, laminar and incompressible flow of the nanofluid filled inside wavy enclosure in which one of the walls is sinusoidal such that the amplitude (A = 0.15) and number of undulations (n = 2) are fixed. A uniform magnetic field B0 has been applied at an inclination angle γ. The governing equations for the transport phenomena have been solved numerically by implementing element-free Galerkin method (EFGM) with the sequential as well as parallel approach. The effect of various parameters, namely, nanoparticle volume fraction (φ), Rayleigh number (Ra), Hartmann number (Ha) and magnetic field inclination angle (γ) has been studied on the natural convection flow of nanofluid. Findings The results are obtained in terms of average Nusselt number calculated at the cold wavy wall, streamlines and isotherms. It has been observed that the increasing value of Rayleigh number results in increased heat transfer rate while the Hartmann number retards the fluid motion. On the other hand, the magnetic field inclination angle gives rise to the heat transfer rate up to its critical value. Above this value, the heat transfer rate starts to decrease. Originality/value The implementation of the magnetic field and its inclination has provided very interesting results on heat and fluid flow which can be used in the drug delivery where nanofluids are used in many physiological problems. Another important novelty of the paper is that meshfree method (EFGM) has been used here because the domain is irregular. The results have been found to be very satisfactory. In addition, parallelization of the scheme (which has not been implemented earlier in such problems) improves the computational efficiency.


2019 ◽  
Vol 3 (4) ◽  
pp. 263-273 ◽  
Author(s):  
Sumer Bharat Dirbude ◽  
Vivek Kumar Maurya

Melting phenomena occurs in various industrial applications, such as metal castings of turbine blades, environmental engineering, PCM-based thermal storage devices, etc. During the design of these devices, they are designed for efficient heat transfer rate. To improve the heat transfer rate, understanding of the important flow processes during the melting (and solidification) is necessary. An objective of the present work is to study the effect of natural convection and magnetic field on interface morphology and thereby on melting rate. In this work, therefore, an effect of uniform transverse magnetic field on the melting inside a cavity, filled initially with solid gallium, at various Rayleigh numbers (Ra=3×105, 6×105, and 9×105) is presented. A 2D unsteady numerical simulation, with the enthalpy-porosity formulation, is performed using ANSYS-Fluent. The magnetic field is characterized by the Hartmann number (Ha) and the results are shown for the Ha = 0, 30 and 50. The horizontal walls of the cavity are considered insulated and vertical walls are respectively considered hot and cold. It is observed that the role of natural convection during the melting is significant on the temperature distribution and solid-liquid interface. The increased magnetic field (Ha = 30 and 50) found to have a suppressing effect on the dominance of natural convection at all Rayleigh numbers (Ra=3×105, 6×105, and 9×105).


Author(s):  
Basma Souayeh ◽  
Nader Ben-Cheikh ◽  
Brahim Ben-Beya

Purpose The purpose of this paper is to examine numerically the three natural convection of air induced by temperature difference between a cold outer cubic enclosure and a hot inner cylinder. Simulations have been carried out for Rayleigh numbers ranging from 103 to 107 and titled angle of the enclosure from 0° to 90°. The developed mathematical model is governed by the coupled equations of continuity, momentum and energy, and is solved by finite volume method. The effects of cylinder inclination and Rayleigh number on fluid flow and heat transfer are presented. The distribution of isocontours of temperature and isosurfaces of velocity eventually reaches a steady state in the range of Rayleigh numbers between 103 and 107 for titled inclination of 90°; however, for the remaining inclinations, Rayleigh number must be in the range 103-106 to avoid unsteady state, which is manifested by the division of the area containing the maximum local heat transfer rate into three parts for a Rayleigh number equal to 107 and an inclination of 90°. We mention that instability study is not included in the present paper, which is solely devoted to three-dimensional calculations. Results also indicate that optimal average heat transfer rate is obtained for both high Rayleigh number of 106 and high inclination of 90° for the two cases of the inner cylinder and cubical enclosure. Design/methodology/approach The manuscript deals with prediction of the three-dimensional natural convection phenomena in a cubical cavity induced by an isothermal cylinder at the center with different inclinations by simulating the flow using highly numerical methods such as finite volume method. Findings It is found that the local Nusselt number through active walls for titled inclination set at 90°, the symmetry of the flow is conserved and the area containing the maximum heat transfer is divided into three smaller areas situated near the upper portion of the wall, taking the maximum value. That may be due to the preparation of local occurrence of instabilities and bifurcation phenomena that appear for Ra > 107, which is not included in the present paper to save journal space. It was found also that an optimal heat transfer appears when the cylinder orientation becomes vertical (a = 90°). For this inclination, buoyancy forces act upward, corresponding to an aiding situation. In addition, heat transfer rate is increasing with Rayleigh numbers, so correlations of average Nusselt through the cubical cavity and the cylinder are established as function of two parameters (Ra, a). Comparisons of the numerical results with those obtained from all correlations show good agreements. Originality/value To the author’s knowledge, studies have thus far adressed three-dimensional cuboids enclosures induced by an inner shape which the location is changed. However, no study has examined three-dimensional natural convection between the inner isothermal cylinder and outer cooled cubical enclosure when the outer enclosure is tilted.


2013 ◽  
Vol 796 ◽  
pp. 623-629
Author(s):  
Kaoru Wakatsuki ◽  
Norimasa Morii ◽  
Yoshio Ogawa ◽  
Hajime Tsuji

During firefighting, within firefighter clothing, underwear and station wear gets heavily wet due to firefighting water and moisture from the body. Water has higher thermal conductivity relative to air and it has been expected that heavily wet condition within the firefighter clothing makes faster skin burns. The objective of this study is how the wet condition within a firefighter clothing makes faster heat transfer from feeling pain and to being 2nd degree of skin burns relative to the dry condition in case of routine firefighting operation in a building (up to 20 kW/m2). Aramid station wear and cotton underwear, generally used by a Japanese firefighter, have been selected and cut 0.15 m x 0.15 m to attach an ISO 9151 copper sensor. A cone shape electric heater, which produces 12 kW/m2 to 20 kW/m2, was used to heat the fabrics. Scenario of fabrics are that (1) wet station wear and dry underwear, (2) wet station and wet underwear, (3) dry station wear and wet underwear, and (4) dry station wear and dry underwear. Evaluation method was by a heat transfer index (HTI) by ISO 9151. The time to rise temperature of 12 and 24 °C (HTI12 and HTI24), and heat transfer rate (dT/dt) were investigated for above four scenarios. The result shows that there was significant impact by condition of station wear, but little impact by underwear. In heat transfer rate (dT/dt) analysis, for the situation of feeling pain to the 2nd degree of skin burns (from HTI12 to HTI24), heat transfer rate was about 50% higher relative to the dry station wear condition. This result indicates that it is possible to be 2nd degree of skin burns easily as soon as a firefighter feels the pain, if he/she wears wet station wear.


2019 ◽  
Vol 29 (4) ◽  
pp. 1466-1489 ◽  
Author(s):  
Mohammadhossein Hajiyan ◽  
Shohel Mahmud ◽  
Mohammad Biglarbegian ◽  
Hussein A. Abdullah ◽  
A. Chamkha

Purpose The purpose of this paper is to investigate the convective heat transfer of magnetic nanofluid (MNF) inside a square enclosure under uniform magnetic fields considering nonlinearity of magnetic field-dependent thermal conductivity. Design/methodology/approach The properties of the MNF (Fe3O4+kerosene) were described by polynomial functions of magnetic field-dependent thermal conductivity. The effect of the transverse magnetic field (0 < H < 105), Hartmann Number (0 < Ha < 60), Rayleigh number (10 <Ra <105) and the solid volume fraction (0 < φ < 4.7%) on the heat transfer performance inside the enclosed space was examined. Continuity, momentum and energy equations were solved using the finite element method. Findings The results show that the Nusselt number increases when the Rayleigh number increases. In contrast, the convective heat transfer rate decreases when the Hartmann number increases due to the strong magnetic field which suppresses the buoyancy force. Also, a significant improvement in the heat transfer rate is observed when the magnetic field is applied and φ = 4.7% (I = 11.90%, I = 16.73%, I = 10.07% and I = 12.70%). Research limitations/implications The present numerical study was carried out for a steady, laminar and two-dimensional flow inside the square enclosure. Also, properties of the MNF are assumed to be constant (except thermal conductivity) under magnetic field. Practical implications The results can be used in thermal storage and cooling of electronic devices such as lithium-ion batteries during charging and discharging processes. Originality/value The accuracy of results and heat transfer enhancement having magnetic field-field-dependent thermal conductivity are noticeable. The results can be used for different applications to improve the heat transfer rate and enhance the efficiency of a system.


2019 ◽  
Vol 20 (1) ◽  
pp. 229-244
Author(s):  
Mehdi Ahmadi ◽  
Seyed Ali Agha Mirjalily ◽  
Seyed Amir Abbas Oloomi

ABSTRACT: This study is conducted to investigate turbulent natural convection flow in an enclosure with thermal sources using the low-Reynolds number (LRN) k-? model. This enclosure has a cold source with temperature Tc and a hot source with temperature Th as thermal sources, other walls of the enclosure are adiabatic. The aim of this study is to predict the effect of change in Rayleigh number, repositioning of cold and hot sources, and thermal sources aspect ratio on the flow field, temperature, and rate of heat transfer. To achieve this aim, the equations of continuity, momentum, energy, turbulent kinetic energy, and kinetic energy dissipation are employed in the case of 2D turbulence with constant thermo-physical properties except the density in the buoyancy term (Boussinesq approximation). To numerically solve these equations, the finite volume method and SIMPLE algorithm are used. According to the modeling results, the most optimal temperature distribution in the enclosure is seen when the hot source is below the cold source. With decreasing distance between hot and cold sources, heat transfer rate increases. The maximal heat transfer rate is derived via study of the heating sources aspect ratio. In constant positions of cold and hot sources on a wall, the heat transfer rate increases with increasing Rayleigh number (Ra=109-1011). ABSTAK: Kajian ini dijalankan bagi mengkaji perubahan semula jadi aliran perolakan dalam tempat tertutup dengan sumber haba menggunakan model k-? nombor Reynolds-rendah (LRN). Bekas tertutup ini mempunyai dua sumber haba iaitu sumber sejuk dengan suhu Tc dan sumber panas dengan suhu Th, manakala dinding lain bekas ini adalah adiabatik. Tujuan kajian ini adalah bagi mengesan perubahan nombor Rayleigh, mengubah sumber sejuk dan panas dan nisbah sumber haba kepada kawasan aliran, suhu dan halaju perubahan haba. Bagi mencapai tujuan tersebut, persamaan sambungan, momentum, tenaga, tenaga kinetik perolakan, dan pengurangan tenaga kinetik telah dilaksanakan dalam kes perolakan 2D dengan sifat fizikal-haba berterusan (malar) kecuali isipadu terma keapungan (anggaran Boussinesq). Bagi menyelesaikan persamaan ini secara berangka, kaedah isipadu terhad dan algorithma MUDAH telah digunakan. Berdasarkan keputusan model, suhu distribusi optimal dalam bekas tertutup dilihat apabila sumber panas adalah kurang daripada sumber sejuk. Dengan pengurangan jarak antara sumber panas dan sejuk, kadar pertukaran haba meningkat. Kadar pertukaran haba maksima telah diperoleh melalui kajian nisbah  aspek sumber pemanasan. Kadar pertukaran haba bertambah dengan bertambahnya nombor Rayleigh  (Ra=109-1011), pada posisi tetap sumber sejuk dan panas pada dinding bekas.


Sign in / Sign up

Export Citation Format

Share Document