An Analytical Comparison of Adsorption and Vapor Compression Air Conditioners for Electric Vehicle Applications

1996 ◽  
Vol 118 (1) ◽  
pp. 16-21 ◽  
Author(s):  
S. M. Aceves

This paper shows an analysis of the applicability of an adsorption system for electric vehicle (EV) air conditioning. Adsorption systems are designed and optimized to provide the required cooling for four combinations of vehicle characteristics and driving cycles. The resulting adsorption systems are compared with vapor compression air conditioners that can satisfy the cooling load. The objective function is the overall system weight, which includes the cooling system weight and the weight of the battery necessary to provide energy for air conditioner operation. The system with the minimum overall weight is considered to be the best. The results show the optimum values of all the variables, as well as temperatures and amounts adsorbed, for the adsorption and desorption processes. The results indicate that, for the conditions analyzed in this paper, vapor compression air conditioners are superior to adsorption systems, not only because they are lighter, but also because they have a higher COP and are more compact.

2016 ◽  
Vol 836 ◽  
pp. 90-95
Author(s):  
Mukhlis A. Hamarung ◽  
Harman ◽  
Jasman

The comfort of a workspace for some people is a thing which is not negotiable. It is believed to raise the motivation of people who work in it. A room which is too hot or too cold may cause people working in it unable to concentrate in a manner that their work performance will not be optimal or will cause some of their work delayed and eventually lead to the depression of the workers themselves. From an economic standpoint, this analysis is important because the greater the capacity of the air conditioning system, the greater the power consumption. The purpose of this study is to determine the amount of heat, which is caused by external and internal factors, that arise in the Engineering building at Engineering Academy of Soroako, and to determine the proper capacity of air conditioners which should be installed in the building. To determine the amount of air conditioning capacity needed in the building, an analysis of the cooling load that occurs in the building is necessary. Geographical position, direction of the wall, and building materials are very influential in the absorption of heat from the outside, while the activities of the occupants, lighting loads, and loads of other electrical equipment affects the amount of heat that arise. CLTD / CLF / SCL methods are used in the calculation, and the data required is measured at the peak of the dry season, which occurs in October. Our analysis and calculations obtained that, according to its function, the number of lamps needed in the building are 26 type PL lamps with a power of 23 watts per lamp. The conduction heat gains and maximum daily infiltration occurred at 2pm with a value of 7.51 kW and 1.98 kW, respectively, while the internal heat gains and maximum daily radiation occurred at 3pm with a value of 1.94 kW and 15.41 kW, respectively. It is concluded that the total maximum daily heat gains that arises is 26.50 kW so the capacity of the air conditioner needed is 6.61 kW or rounded to 8.9 PK.


Author(s):  
Arunkumar Damodharan ◽  
Ramu Murugan ◽  
Syath Abuthakeer

Increasing the energy ratio of an air conditioner that has a cooled air condenser is a difficult problem, particularly in areas where the temperature and humidity are very high. The efficiency of air conditioners based on standard vapor compression technology can be enhanced by combining active cooling technologies with less energy-intensive inactive cooling technologies. In this study, the cooling performance of combined cooling systems has been experimentally explored. Using four different modes of a hybrid ground-coupled heat exchanger (GCHE), an analysis was carried out to enhance the energy ratio of the active cooling system connected to the GCHE. This was achieved by using the fact that the GCHE outlet air temperature is lower than the ambient temperature and can directly supply space heating or cooling to the condenser tubes of conventional air conditioners. It was observed that with the use of a GCHE for the condenser tubes, the energy consumption of a traditional window air conditioner was reduced by 16.18%.


2020 ◽  
Vol 38 (7A) ◽  
pp. 984-991
Author(s):  
Krar M. Kuder ◽  
Hashim A. Hussein ◽  
Ali H. Numan

The present research paper is on photovoltaic air conditioning system using the direct drive method. The experimental system setup arranged in Iraq at Al-taje site at longitude 44.34 and latitude 33.432 during the summer season inside a room. The proposed off-grid system consists of an array of photovoltaic, battery used to store power, PWM (pulse width modulation) charge controller, and DC air cooler. During the examination of the system, proven success of this new type(dc air conditioner ) of client urges Iraq warm conditions as an alternative type used instead of the prevailing types of air conditioners (AC air conditioner )in Iraq which consume large amounts of electrical energy and gets a cooling system for the room full working on solar energy.                                                                                                                


The work is aimed to replace conventional refrigerants used in air cooling system with Air Cycle Machine (ACM). Commercial Air-conditioners uses the refrigerants (Freon-Gas cycle) to remove the indoor air from the room. Freon leakage causes health problems such as respiratory ailments, heart attack and circulatory collapse. Air conditioning systems made based on desiccants. Refrigerant poisoning results in Throat swelling, loss of vision, blood vomiting, blood in the stool, severe abdominal pain and even death is possible. This can be overcome by using air cycle cooling process instead of Freon as a phase changing material. Air Cycle Machine is the system used in aircraft cabin pressurization and cooling system which does not uses refrigerants in the cooling process. The analytical work carried out in this paper is to study the air conditioning system using Air Cycle Machine and investigate the air flow inside the room by giving the various inlet temperatures and the inlet velocity of the Air-conditioner. ANSYS-FLUENT 16.0 is used for the analytical study. A cabin enclosure was modeled and analyzed for different inlet temperatures and velocities and out coming cool air spread nature for the given conditions have been observed. The qualitative results of this study clearly evident the usage of Air Cycle Machine (ACM) is prominently reduces the room temperature than the refrigerant system and spreads the cool air throughout the enclosed room makes a comfortable environment and this would not leads to any health hazards. Thus this study is certain to use Air Cycle Machine (ACM) for the cabin cooling system rather than refrigerants.


2015 ◽  
Vol 1125 ◽  
pp. 556-560 ◽  
Author(s):  
Sumeru ◽  
Triaji P. Pramudantoro ◽  
Farid Nasir Ani ◽  
Henry Nasution

Most air conditioners utilize vapor compression refrigeration cycle in their operation. In this cycle, the compressor is deployed to circulate the refrigerant from low to high pressures. Lubrication is an important aspect in the compressor to lubricate internal parts. Due to their remarkable properties in the thermo-physical and heat transfer capabilities, nanoparticles have prospect to be applied in the refrigeration and air conditioning system. The reliability and solubility nanoparticle of TiO2 in refrigeration systems have been investigated by several by several researchers. By introducing TiO2 nanoparticle in the lubricant, the friction coefficient and input power of the compressor can be decreased. An air conditioner with cooling capacity of 2.5 kW is utilized in the experiment. Five different concentrations of nanoparticle in the lubricant, viz.: 0.1, 0.2, 0.4, 0.5 and 0.6 gram of TiO2 in one liter of lubricant were mixed using a magnetic stirrer. After 10 days, TiO2 nanoparticles in the lubricant were observed its solubility. Furthermore, based on their solubility, TiO2 nanoparticle with concentration of 0.2 g/L was selected in the experiments. The results show that the air conditioner using R290 with TiO2 nanoparticle in the lubricants works normally and the input power of the air conditioner decreases about 3.1% and the cooling capacity and the COP increase about 5.1% and 8.4%, respectively, compared to the system without nanoparticle in the lubricant.


Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4663
Author(s):  
Tatsuhiro Yamamoto ◽  
Akihito Ozaki ◽  
Myonghyang Lee

The number of houses with large, continuous spaces has increased recently. With improvements in insulation performance, it has become possible to efficiently air condition such spaces using a single air conditioner. However, the air conditioning efficiency depends on the placement of the air conditioner. The only way to determine the optimal placement of such air conditioners is to conduct an experiment or use computational fluid dynamic analysis. However, because the analysis is performed over a limited period, it is difficult to consider non-stationarity effects without using an energy simulation. Therefore, in this study, energy simulations and computational fluid dynamics analyses were coupled to develop a thermal environment analysis method that considers non-stationarity effects, and various air conditioner arrangements were investigated to demonstrate the applicability of the proposed method. The accuracy verification results generally followed the experimental results. A case study was conducted using the calculated boundary conditions, and the results showed that the placement of two air conditioners in the target experimental house could provide sufficient air conditioning during both winter and summer. Our results suggest that this method can be used to conduct preliminary studies if the necessary data are available during design or if an experimental house is used.


2017 ◽  
Vol 140 (1) ◽  
Author(s):  
Carlos R. de Nardin ◽  
Felipe T. Fernandes ◽  
Adriano J. Longo ◽  
Luciano P. Lima ◽  
Felix A. Farret ◽  
...  

This paper presents a comparison of air conditioners using the conventional heating, ventilation, and air conditioning heat pumps and the one using solar heat stored underground, also known as shallow geothermal air conditioning. The proposed air conditioner with solar heat stored underground reunites practical data from an implementation of the heuristic perturb-and-observe (P&O) control and a heat management technique. The aim is to find out the best possible heat exchange between the room ambient and the underground soil heat to reduce its overall consumption without any heat pump. Comparative tests were conducted in two similar rooms, each one equipped with one of the two types of air conditioning. The room temperature with the conventional air conditioning was maintained as close as possible to the temperature of the test room with shallow geothermal conditioning to allow an acceptable data validation. The experiments made both in the winter of 2014 and in the summer of 2015 in Santa Maria, South Brazil, demonstrated that the conventional air conditioner consumed 19.08 kWh and the shallow geothermal conditioner (SGC) consumed only 4.65 kWh, therefore, representing a reduction of energy consumption of approximately 75%.


Author(s):  
Yilin Du ◽  
Jan Muehlbauer ◽  
Jiazhen Ling ◽  
Vikrant Aute ◽  
Yunho Hwang ◽  
...  

A rechargeable personal air-conditioning (RPAC) device was developed to provide an improved thermal comfort level for individuals in inadequately cooled environments. This device is a battery powered air-conditioning system with the phase change material (PCM) for heat storage. The condenser heat is stored in the PCM during the cooling operation and is discharged while the battery is charged by using the vapor compression cycle as a thermosiphon loop. The conditioned air is discharged towards a single person through adjustable nozzle. The main focus of the current research was on the development of the cooling system. A 100 W cooling capacity prototype was designed, built, and tested. The cooling capacity of the vapor compression cycle measured was 165.6 W. The PCM was recharged in nearly 8 hours under thermosiphon mode. When this device is used in the controlled built environment, the thermostat setting can be increased so that building air conditioning energy can be saved by about 5–10%.


2014 ◽  
Vol 699 ◽  
pp. 828-833 ◽  
Author(s):  
Sumeru ◽  
Markus ◽  
Farid Nasir Ani ◽  
Henry Nasution

Air conditioning system consumes approximately 50% of the total energy consumption of buildings. Split-type air conditioner is the most widely used in residential and commercial buildings. As a result, enhancement on the performance of the air conditioners will yield a significant energy savings. The use of ejector as an expansion device on the split-type air conditioners is one method to increase the system performance. Exergy analysis on a split-type air conditioner uses an ejector as an expansion device at room and outdoor temperatures of 24 °C and 34 °C, respectively, yielded the percentage of exergy reduction up to 40.6%. Also, the exergy losses on in the compressor had the highest impact on the performance improvement of the split-type air conditioner.