scholarly journals Flow Boiling Heat Transfer in Microchannels

2006 ◽  
Vol 129 (10) ◽  
pp. 1321-1332 ◽  
Author(s):  
Dong Liu ◽  
Suresh V. Garimella

Flow boiling heat transfer to water in microchannels is experimentally investigated. The dimensions of the microchannels considered are 275×636 and 406×1063μm2. The experiments are conducted at inlet water temperatures in the range of 67–95°C and mass fluxes of 221–1283kg∕m2s. The maximum heat flux investigated in the tests is 129W∕cm2 and the maximum exit quality is 0.2. Convective boiling heat transfer coefficients are measured and compared to predictions from existing correlations for larger channels. While an existing correlation was found to provide satisfactory prediction of the heat transfer coefficient in subcooled boiling in microchannels, saturated boiling was not well predicted by the correlations for macrochannels. A new superposition model is developed to correlate the heat transfer data in the saturated boiling regime in microchannel flows. In this model, specific features of flow boiling in microchannels are incorporated while deriving analytical solutions for the convection enhancement factor and nucleate boiling suppression factor. Good agreement with the experimental measurements indicates that this model is suitable for use in analyzing boiling heat transfer in microchannel flows.

1990 ◽  
Vol 112 (1) ◽  
pp. 219-228 ◽  
Author(s):  
S. G. Kandlikar

A simple correlation was developed earlier by Kandlikar (1983) for predicting saturated flow boiling heat transfer coefficients inside horizontal and vertical tubes. It was based on a model utilizing the contributions due to nucleate boiling and convective mechanisms. It incorporated a fluid-dependent parameter Ffl in the nucleate boiling term. The predictive ability of the correlation for different refrigerants was confirmed by comparing it with the recent data on R-113 by Jensen and Bensler (1986) and Khanpara et al. (1986). In the present work, the earlier correlation is further refined by expanding the data base to 5246 data points from 24 experimental investigations with ten fluids. The proposed correlation, equations (4) and (5), along with the constants given in Tables 3 and 4, gives a mean deviation of 15.9 percent with water data, and 18.8 percent with all refrigerant data, and it also predicts the correct hTP versus x trend as verified with water and R-113 data. Additional testing with recent R-22 and R-113 data yielded the lowest mean deviations among correlations tested. The proposed correlation can be extended to other fluids by evaluating the fluid-dependent parameter Ffl for that fluid from its flow boiling or pool boiling data.


Author(s):  
Maritza Ruiz ◽  
Claire M. Kunkle ◽  
Jorge Padilla ◽  
Van P. Carey

This study presents an experimental exploration of flow boiling heat transfer in a spiraling radial inflow microchannel heat sink. The effect of surface wettability, fluid subcooling levels, and mass fluxes are considered in this type of heat sink for use in applications with high fluxes up to 300 W/cm2. The design of the heat sink provides an inward radial swirl flow between parallel, coaxial disks that form a microchannel of 300 μm and 1 cm radius with a single inlet and a single outlet. The channel is heated on one side through a copper conducting surface, while the opposite side is essentially adiabatic to simulate a heat sink scenario for electronics cooling. Flow boiling heat transfer and pressure drop data were obtained for this heat sink device using water at near atmospheric pressure as the working fluid for inlet subcooling levels from 20 to 81°C and mean mass flux levels ranging from 184 to 716 kg/m2s. To explore the effects of varying surface wetting, experiments were conducted with two different heated surfaces. One was a clean, machined copper surface with water equilibrium contact angles in the range of 14–40°, typical of common metal surfaces. The other was a surface coated with zinc oxide nanostructures that are superhydrophilic with equilibrium contact angles measured below 10°. During boiling, increased wettability resulted in quicker rewetting and smaller bubble departure diameter as indicated by reduced temperature oscillations during boiling and achieving higher maximum heat flux without dryout. Reducing inlet subcooling levels was also found to reduce the magnitude of oscillations in the oscillatory boiling regime. The highest heat transfer coefficients were seen in fully developed boiling with low subcooling levels as a result of heat transfer being dominated by nucleate boiling. The highest heat fluxes achieved were during partial subcooled flow boiling at 300 W/cm2 with an average surface temperature of 134 °C and requiring a pumping power to heat rate ratio of 0.01%. The hydrophilic surface retained wettability after a series of boiling tests. Recommendations for use of this heat sink design in high flux applications is also discussed.


Author(s):  
Wenzhi Cui ◽  
Longjian Li ◽  
Mingdao Xin ◽  
Tien-Chien Jen ◽  
Qinghua Chen ◽  
...  

In the research of intube flow boiling, a widely accepted factor is that there are two main mechanisms participating in the heat transfer. One is nucleate boiling, which is dependent on the presence of active nuclei on the heated wall and the heat transfer coefficient is much influenced by the heat flux, much similar to pool boiling. In the other heat transfer mode, the boiling nuclei are fully suppressed and heat is transferred by the liquid evaporation through the interface of liquid film and vapor core. This is also called forced convective evaporation or convective boiling. In the evaporation region, the dependence of heat transfer on heat flux is not distinct and governed mainly by the mass flux and vapor quality. In the open literature on convective boiling heat transfer of refrigerant researches have been extensively conducted in straight tube. The studies, however, on two-phase flow boiling heat transfer in helically coiled tube are far less than that in straight tube. Because of the high efficiency in heat transfer and compactness in volume, helically coiled tubes are used extensively in practical industries. Therefore, it is important for application to obtain the correlations of flow boiling heat transfer coefficient in helically coiled tube. A new kind of micro-finned helically coiled tube was developed by the present authors and the flow boiling heat transfer characteristics are experimental studied in this paper, using R134a, an environment-friendly refrigerant as experimental fluid. By introducing convective boiling number NCB, as suggested by V. V. Klimenko (in Ref. [8]), the transition boundary between nucleate boiling and forced convective boiling in helically coiled tube is examined, which is much different with that in straight tube. Based on the analysis of the mechanisms of flow boiling, heat transfer correlation of the specific micro-finned helically coiled tubes is obtained, which has a mean absolute deviation of 13.8%.


Author(s):  
Dong Liu ◽  
Suresh V. Garimella

Flow boiling heat transfer in a microchannel heat sink is experimentally investigated. The microchannels considered are 275 μm wide and 636 μm deep, and the experiments are conducted at inlet water temperatures in the range of 66 to 95°C and mass fluxes of 341 to 936 kg/m2s. Convective boiling heat transfer coefficients are measured and compared to predictions from correlations proposed for larger channels. While an existing correlation was found to provide satisfactory prediction of the heat transfer coefficient in subcooled boiling in the microchannels, saturated boiling was not well predicted by the correlations for macrochannels. A new heat transfer model is developed to correlate the data in the saturated boiling regime. Good agreement with the experimental measurements indicates that this correlation is suitable for use in the design of two-phase microchannel heat sinks.


2005 ◽  
Vol 127 (12) ◽  
pp. 1305-1312 ◽  
Author(s):  
Chang Yong Park ◽  
Pega S. Hrnjak

Flow boiling heat transfer coefficients of CO2 are measured in a horizontal smooth tube with inner diameter 6.1mm. The test tube is heated by a secondary fluid maintaining constant wall temperature conditions. Heat transfer coefficients are measured at evaporation temperatures of −15 and −30°C, mass flux from 100to400kg∕m2s, and heat flux from 5to15kW∕m2 for qualities (vapor mass fractions) ranging from 0.1 to 0.8. The characteristics of CO2 flow boiling are explained by CO2 properties and flow patterns. The measured CO2 heat transfer coefficients are compared to other published data. Experiments with R22 were also conducted in the same system and the results show that the heat transfer coefficients for CO2 are 40 to 150% higher than for R22 at −15°C and low mass flux of 200kg∕m2s mostly due to the characteristics of CO2 nucleate boiling. The presented CO2 heat transfer coefficients indicate the reduction of heat transfer coefficient as mass flux increases at low quality regions and also show that dryout does not occur until the high quality region of 0.8, for mass fluxes of 200 and 400kg∕m2s. The Gungor and Winterton correlation gives a relatively good agreement with measured data; however it deviates more at lower evaporation temperature and high mass flux conditions.


Author(s):  
K. H. Bang ◽  
W. H. Choo

The past work on flow boiling heat transfer in minichannels ranging one to three millimeters of hydraulic diameter has indicated that the local heat transfer coefficients are largely independent of mass flux and vapor quality, but mainly a function of wall heat flux. The present work is a revisit of flow boiling in minichannels by conducting experiment using 1.67 mm inner diameter tubes of three different materials; aluminum, brass, and copper, to investigate an effect of the tube inner surface conditions with the focus on an effect on nucleate boiling. Tests were conducted for R-22, a fixed mass flux of 600 kg/m2s, 5∼30 kW/m2 of wall heat flux, 0.0∼0.9 of local vapor quality. The present experimental data confirmed that the flow boiling heat transfer coefficient in a minichannel varies only by heat flux, independent of mass flux and vapor quality. The effect of tube material was found small for the tubes used in the present work. The present data were well predicted by the correlation proposed by Tran et al. (1996).


1999 ◽  
Author(s):  
Yasuo Koizumi ◽  
Hiroyasu Ohtake ◽  
Manabu Mochizuki

Abstract The effect of solid particle introduction on subcooled-forced flow boiling heat transfer and a critical heat flux was examined experimentally. In the experiment, glass beads of 0.6 mm diameter were mixed in subcooled water. Experiments were conducted in a range of the subcooling of 40 K, a velocity of 0.17–6.7 m/s, a volumetric particle ratio of 0–17%. When particles were introduced, the growth of a superheated liquid layer near a heat trasnsfer surface seemed to be suppressed and the onset of nucleate boiling was delayed. The particles promoted the condensation of bubbles on the heat transfer surface, which shifted the initiation of a net vapor generation to a high heat flux region. Boiling heat trasnfer was augmented by the particle introduction. The suppression of the growth of the superheated liquid layer and the promotion of bubble condensation and dissipation by the particles seemed to contribute that heat transfer augmentation. The wall superheat at the critical heat flux was elevated by the particle introduction and the critical heat flux itself was also enhanced. However, the degree of the critical heat flux improvement was not drastic.


1999 ◽  
Author(s):  
Lixin Cheng ◽  
Tingkuan Chen

Abstract Experiments of upward flow boiling heat transfer with water in a vertical smooth tube and a tube with axial micro-grooves were respectively conducted. Both of the tested tubes have a length of 2.5 m, an inner diameter of 15 mm and an outlet diameter of 19 mm. The tube with axial micro grooves has many micro rectangle grooves in its inner wall along the axial direction. The grooves have a depth of 0.5 mm and a width of 0.3 mm. The tests were performed at an absolute pressure of 6 bar. The heat flux ranged from 0 to 550 kW/m2 and the mass flux was selected at 410, 610 and 810 kg/m2s, respectively. By comparison, flow boiling heat transfer coefficients in the enhanced tube are 1.6 ∼ 2.7 fold that in the smooth tube while the frictional pressure drop in the enhanced tube is slightly greater than that in the smooth tube. The augmentation of flow boiling heat transfer in the tube with axial micro-grooves is apparent. Based on the experimental data, a correlation of flow boiling heat transfer is proposed for the enhanced tube. Finally, the mechanisms of heat transfer enhancement are analyzed.


2009 ◽  
Vol 131 (9) ◽  
Author(s):  
Chang Yong Park ◽  
Pega Hrnjak

Abstract C O 2 flow boiling heat transfer coefficients and pressure drop in a 3.5mm horizontal smooth tube are presented. Also, flow patterns were visualized and studied at adiabatic conditions in a 3mm glass tube located immediately after a heat transfer section. Heat was applied by a secondary fluid through two brass half cylinders to the test section tubes. This research was performed at evaporation temperatures of −15°C and −30°C, mass fluxes of 200kg∕m2s and 400kg∕m2s, and heat flux from 5kW∕m2 to 15kW∕m2 for vapor qualities ranging from 0.1 to 0.8. The CO2 heat transfer coefficients indicated the nucleate boiling dominant heat transfer characteristics such as the strong dependence on heat fluxes at a mass flux of 200kg∕m2s. However, enhanced convective boiling contribution was observed at 400kg∕m2s. Surface conditions for two different tubes were investigated with a profilometer, atomic force microscope, and scanning electron microscope images, and their possible effects on heat transfer are discussed. Pressure drop, measured at adiabatic conditions, increased with the increase of mass flux and quality, and with the decrease of evaporation temperature. The measured heat transfer coefficients and pressure drop were compared with general correlations. Some of these correlations showed relatively good agreements with measured values. Visualized flow patterns were compared with two flow pattern maps and the comparison showed that the flow pattern maps need improvement in the transition regions from intermittent to annular flow.


Sign in / Sign up

Export Citation Format

Share Document