Hybrid Expansion Revisited

2006 ◽  
Vol 129 (3) ◽  
pp. 482-487 ◽  
Author(s):  
Stanley Yokell

This paper describes new hitherto unused procedures that combine hydraulic and explosive expanding to produce tube-to-tubesheet joints in tubular heat transfer equipment with thick tubesheets. This paper also interprets shear load test results and microscopic examination of polished and sectioned specimens used to validate the adequacy of the method for producing strong, leak tight joints. It concludes that the method is successful.

2018 ◽  
Vol 2018 ◽  
pp. 1-16 ◽  
Author(s):  
Rajinder Ghai ◽  
Prem Pal Bansal ◽  
Maneek Kumar

There is a common phenomenon of shear failure in RCC beams, especially in old buildings and bridges. Any possible strengthening of such beams is needed to be explored that could strengthen and make them fit for serviceable conditions. The present research has been made to determine the performance of predamaged beams strengthened with three-layered wire mesh polymer-modified ferrocement (PMF) with 15% styrene-butadiene-rubber latex (SBR) polymer. Forty-eight shear-designed and shear-deficient real-size beams were used in this experimental work. Ultimate shear load-carrying capacity of control beams was found at two different shear-span (a/d) ratios 1 and 3. The sets of remaining beams were loaded with different predetermined damage levels of 45%, 75%, and 95% of the ultimate load values and then strengthened with 20 mm thick PMF. The strengthened beams were then again tested for ultimate load-carrying capacity by conducting the shear load test at a/d = 1 and 3. As a result, the PMF-strengthened beams showed restoration and enhancement of ultimate shear load-carrying capacity by 5.90% to 12.03%. The ductility of strengthened beams was improved, and hence, the corresponding deflections were prolonged. On the other hand, the cracking pattern of PMF-strengthened beams was also improved remarkably.


2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
A. Hemalatha ◽  
N. Mahendran ◽  
G. Ganesh Prabhu

The experimental investigation on the effects of granular fill and geogrid reinforced granular fill on the behaviour of the static liquefaction potential of the subsoil is reported in this study. A series of plate load test were carried out with different thickness of the granular fill, number of geogrid layers, and size/dimension of the footing. The test results were presented in terms of bearing capacity and subgrade modulus for the settlement ofδ10,δ15, andδ20. The experimental results revealed that the introduction of granular fill significantly increases the bearing capacity and effectively control the settlement behaviour of the footing. The introduction of geogrid in granular fill enhanced the Percentage of Control in Settlement and Bearing Capacity Ratio by a maximum of 328.54% and 203.41%, respectively. The introduction of geogrid in granular fill interrupts the failure zone of the granular fill and enhances the subgrade modulus of the footing by a maximum of 255.55%; in addition subgrade modulus of the footing was increased with an increase in the number of geogrid layers. Based on the test results it is suggested that the footing with large size has beneficial improvement on the reinforced granular fill.


1999 ◽  
pp. 267-282
Author(s):  
Kazushi KATO ◽  
Kenichi HORIKOSHI ◽  
Tatsunori MATSUMOTO ◽  
Osamu KUSAKABE
Keyword(s):  

Author(s):  
D. E. Brandt

The MS7001F heavy–duty gas turbine has been designed utilizing advanced analytical methods and a substantial array of component tests. The integrity of the system required that the prototype unit, with its accessories, be rigorously tested under load. The factory load test was completed on May 18, 1988 after 387 hours and 134 start/stop cycles. The MS7001F prototype gas turbine was instrumented with more than 3000 pieces of instrumentation in order to record all critical temperatures, pressures, flows, strains, displacements, and other pertinent data. The load device was a modified MS7001E compressor, which also supplied the means by which the MS7001F prototype compressor’s pressure ratio was increased to provide for surge margin determination. Inlet throttling of the MS7001F compressor allowed for full firing temperature operation, at reduced load. The results of this factory prototype load test are reported in the paper as are observations made during post test teardown.


2013 ◽  
Vol 639-640 ◽  
pp. 943-946
Author(s):  
Jiao Long He ◽  
Yong Zhou ◽  
Zhong Ai Jiang

Based on the reinforcing mechanism of dynamic replacement method ,this article put forward the construction parameters and measures of dynamic replacement method , combining with the result of actual engineering field testing experiment. The field load test, standard penetration test and pore water pressure test results show that the characteristic value of subgrade bearing capacity is more than 130 kpa when the tailings residue subgrade has been managed with dynamic replacement method, providing references for applied research on dynamic replacement method in tailings residue subgrade reinforcement.


2013 ◽  
Vol 790 ◽  
pp. 227-230
Author(s):  
Jian Feng Su ◽  
Yu Feng Xu

Floor slab static load test is a important method to judge the performance and carrying capacity of the slab. This paper, with the background of a factory frame-structure slab, introduced the testing scheme, the details of the testing process as well as the test results. The testing cases provide a useful reference for the same type of project.


1959 ◽  
Vol 81 (1) ◽  
pp. 24-28 ◽  
Author(s):  
Samuel Globe ◽  
David Dropkin

This paper presents results of an experimental investigation of convective heat transfer in liquids placed between two horizontal plates and heated from below. The liquids used were water, silicone oils of 1.5, 50, and 1000 centistoke kinematic viscosities, and mercury. The experiments covered a range of Rayleigh numbers between 1.51(10)5 and 6.76(10)8. and Prandtl numbers between 0.02 and 8750. Tests were made in cylindrical containers having copper tops and bottoms and insulating walls. For water and silicone oils the container was 5 in. in diam and 2 in. high. For mercury, two containers were used, both 5.28 in. in diameter, but one 1.39 in. high and another 2.62 in. high. In all cases the bottom plates were heated by electric heaters. The top plates were air-cooled for the water and silicone-oil experiments and water-cooled for the mercury tests. To prevent amalgamation, the copper plates of the mercury container were chromium plated. Surface temperatures were measured by thermocouples embedded in the plates. The test results indicate that the heat-transfer coefficients for all liquids investigated may be determined from the relationship Nu=0.069Ra13Pr0.074 In this equation the Nusselt and Rayleigh numbers are based on the distance between the copper plates. The results of this experiment are in reasonable agreement with the data reported by others who used larger containers and different fluids.


2020 ◽  
Vol 214 ◽  
pp. 110641 ◽  
Author(s):  
Pengzhen Lu ◽  
Zijie Xu ◽  
Yangrui Chen ◽  
Yutao Zhou

Sign in / Sign up

Export Citation Format

Share Document