Effect of Surface Orientation on Nucleate Boiling of FC-72 on Porous Graphite

2006 ◽  
Vol 128 (11) ◽  
pp. 1159-1175 ◽  
Author(s):  
Jack L. Parker ◽  
Mohamed S. El-Genk

Effects of orientations of porous graphite and smooth copper surfaces, measuring 10mm×10mm, on saturation nucleate boiling and critical heat flux (CHF) of FC-72 dielectric liquid and of liquid subcooling (0, 10, 20, and 30K) on nucleate boiling in the upward facing orientation are investigated. Inclination angles (θ) considered are 0deg (upward-facing), 60, 90, 120, 150, and 180deg (downward facing). The values of nucleate boiling heat flux, nucleate boiling heat transfer coefficient (NBHTC), and CHF are compared with those measured on the smooth copper surface of the same dimensions and CHF values on both copper and porous graphite are compared with those reported by other investigators on the smooth surfaces and microporous coatings. Results demonstrated higher NBHTC and CHF on porous graphite, particularly in the downward-facing orientation (θ=180deg). In the upward-facing orientation, NBHTCs on both surfaces decrease with increased subcooling, but increase with increased surface superheat reaching maxima then decrease with further increase in surface superheat. In saturation boiling on copper and both saturation and subcooled boiling on porous graphite these maxima occur at or near the end of the discrete bubble region, and near CHF in subcooled boiling on copper. Maximum saturation NBHTC on porous graphite increases with decreased surface superheat and inclination angle, while that on copper increases with increased surface superheat and decreased surface inclination. At low surface superheats, saturation nucleate boiling heat flux increases with increased inclination, but decreases with increased inclination at high surface superheats, consistent with previously reported data for dielectric and nondielectric liquids. The fractional decreases in saturation CHF with increased θ on smooth copper and microporous coatings are almost identical, but markedly larger than on porous graphite, particularly in the downward-facing orientation. In this orientation, saturation CHF on porous graphite of 16W∕cm2 is much higher than on copper (4.9W∕cm2) and as much as 53% of that in the upward-facing orientation, compared to only ∼18% on copper.

Author(s):  
Mohamed S. El-Genk ◽  
Jack L. Parker

Experiments are conducted that investigated pool boiling of FC-72 liquid at saturation and 10, 20, and 30 K subcooling on porous graphite and smooth copper surfaces measuring 10 × 10 mm. The nucleate boiling heat flux, Critical Heat Flux (CHF), and surface superheats at boiling incipience are compared. Theses heat fluxes are also compared with those of other investigators for smooth copper and silicon, etched SiO2, surfaces and micro-porous coating. No temperature excursion at boiling incipience on the porous graphite that occurred at a surface superheats of < 1.0 K. Conversely, the temperature excursions of 24.0 K and 12.4–17.8 K are measured at incipient boiling in saturation and subcooled boiling on copper. Nucleate boiling heat fluxes on porous graphite are significantly higher and corresponding surface superheats are much smaller than on copper. CHF on porous graphite (27.3, 39.6, 49.0, and 57.1 W/cm2 in saturation and 10 K, 20 K, and 30 K subcooled boiling, respectively) are 61.5%–207% higher than those on copper (16.9, 19.5, 23.6, and 28.0 W/cm2, respectively). The surface superheats at CHF on the porous graphite of 11.5 K in saturation and 17–20 K in subcooled boiling are significantly lower that those on copper (25 K and 26–28 K, respectively). In addition, the rate of increase of CHF on porous graphite with increased subcooling is ~ 125% higher than that on copper.


Author(s):  
Jack L. Parker ◽  
Mohamed S. El-Genk

Saturation pool boiling experiments of FC-72 liquid on a flat, porous graphite and smooth copper surfaces measuring 10 × 10 mm investigated the effect of surface orientation on nucleate boiling and Critical Heat Flux (CHF). The inclination angle of the surface increased from 0° (upward-facing) to 60°, 90°, 120°, 150°, and 180° (downward facing). Results demonstrated significant increases in the nucleate boiling heat transfer coefficient and CHF on porous graphite, compared to those on copper. At low surface superheats, increasing the inclination angle increases the nucleate boiling heat transfer coefficient, which decreases with increased inclination angle at high surface superheats. These results and the measured decreases of CHF with increased inclination angle are consistent with those reported earlier by other investigators for dielectric and non-dielectric liquids. On smooth surfaces and micro-porous coatings, the reported fractional decreases in CHF with increased inclination angle are almost identical, but markedly larger than those measured in this work on porous graphite. On these surfaces the reported CHF in the downward-facing position (180° inclination) is ∼10–20% of that in the upward-facing position (0° inclination), compared to ∼53.3% on porous graphite. The CHF values of FC-72 liquid on porous graphite, which also decreased with increased inclination angle, are correlated using the general form suggested by Kutatelatze (1961) to within ± 5% of the experimental data.


Author(s):  
Joo H. Kim ◽  
Madhav R. Kashinath ◽  
Sang M. Kwark ◽  
Seung M. You

The present research is an experimental study for the enhancement of boiling heat transfer using microporous coating techniques. The effects of different metal particle sizes in the coating compound for microporous coatings on pool boiling performance of refrigerants and water are investigated. All boiling tests were performed with 1×1cm2 test heaters in the horizontal, upward-facing orientation under increasing heat flux conditions at atmospheric pressure in saturated R-123, FC-72, and water. Results showed that the enhanced surface by microporous coating technique significantly augmented both nucleate boiling heat transfer coefficient and critical heat flux of FC-72 and R-123 over a plain surface. However, the enhancement of boiling performance for water was comparatively insignificant compared to the other liquids.


2012 ◽  
Vol 550-553 ◽  
pp. 2913-2916 ◽  
Author(s):  
Jin Liang Tao ◽  
Xin Liang Wang ◽  
Pei Hua Shi ◽  
Xiao Ping Shi

In this paper, a new porous coating was formed directly on the surface of titanium metal via anodic oxidation. And by the SEM, the morphology of the coating, which is composed of well-ordered perpendicular nanotubes, was characterized. Moreover, taking deionized water as the test fluid, a visualization study of the coating on its pool boiling heat transfer performance was made. The results demonstrated that compared with the smooth surface, the nucleate boiling heat transfer coefficient can increase 3 times while the nucleate boiling super heat was reduced 30%.


Author(s):  
Muhamad Zuhairi Sulaiman ◽  
Masahiro Takamura ◽  
Kazuki Nakahashi ◽  
Tomio Okawa

Boiling heat transfer (BHT) and critical heat flux (CHF) performance were experimentally studied for saturated pool boiling of water-based nanofluids. In present experimental works, copper heaters of 20 mm diameter with titanium-oxide (TiO2) nanocoated surface were produced in pool boiling of nanofluid. Experiments were performed in both upward and downward facing nanofluid coated heater surface. TiO2 nanoparticle was used with concentration ranging from 0.004 until 0.4 kg/m3 and boiling time of tb = 1, 3, 10, 20, 40, and 60 mins. Distilled water was used to observed BHT and CHF performance of different nanofluids boiling time and concentration configurations. Nucleate boiling heat transfer observed to deteriorate in upward facing heater, however; in contrast effect of enhancement for downward. Maximum enhancements of CHF for upward- and downward-facing heater are 2.1 and 1.9 times, respectively. Reduction of mean contact angle demonstrate enhancement on the critical heat flux for both upward-facing and downward-facing heater configuration. However, nucleate boiling heat transfer shows inconsistency in similar concentration with sequence of boiling time. For both downward- and upward-facing nanocoated heater's BHT and CHF, the optimum configuration denotes by C = 400 kg/m3 with tb = 1 min which shows the best increment of boiling curve trend with lowest wall superheat ΔT = 25 K and critical heat flux enhancement of 2.02 times.


Author(s):  
Bao H. Truong

Nanofluids are engineered colloids composed of nano-size particles dispersed in common fluids such as water or refrigerants. Using an electrically controlled wire heater, pool boiling Critical Heat Flux (CHF) of Alumina and Silica water-based nanofluids of concentration less than or equal to 0.1 percent by volume were measured. Silica nanofluids showed a CHF enhancement up to 68% and there seems to be a monotonic relationship between the nanoparticle concentration and the magnitude of enhancement. Alumina nanofluids had a CHF enhancement up to 56% but the peak occurred at the intermediate concentration. The boiling curves in nanofluid were found to shift to the left of that of water and correspond to higher nucleate boiling heat transfer coefficients in the two-phase flow regime. Scanning Electron Microscopy (SEM) images show a porous coating layer of nanoparticles on wires subjected to nanofluid CHF tests. These coating layers change the morphology of the heater’s surface, and are responsible for the CHF enhancement. The thickness of the coating was estimated using SEM and was found ranging from 3.0 to 6.0 micrometers for Alumina, and 3.0 to 15.0 micrometers for Silica.


1985 ◽  
Vol 107 (1) ◽  
pp. 168-174 ◽  
Author(s):  
E. A. Ibrahim ◽  
R. L. Judd

The effect of subcooling on bubble waiting time and growth time for water boiling on a copper surface was examined in conjunction with measurements obtained over a range of subcooling from 0 to 15°C and three different levels of heat flux 166, 228, and 291 kW/m2. The growth-time data was successfully correlated with a model that combined the bubble growth theory of Mikic, Rohsenow, and Griffith with the bubble departure diameter relationship of Staniszewski, thereby establishing confidence in the measuring procedure. The waiting time data agreed with the predictions of the Han and Griffith waiting time theory at lower levels of subcooling but then showed a behavior contrary to that predicted for higher levels of subcooling.


Author(s):  
Bambang Joko Suroto ◽  
Masahiro Tashiro ◽  
Sana Hirabayashi ◽  
Sumitomo Hidaka ◽  
Masamichi Kohno ◽  
...  

The effects of hydrophobic circle spot size and subcooling on local film boiling phenomenon from the copper surface with single PTFE (Polytetrafluoroethylene) hydrophobic circle spot at low heat flux has been investigated. The experiments were performed using pure water as the working fluid and subcooling ranging from 0 and 10K. The heat transfer surfaces are used polished copper block with single PTFE hydrophobic circle spot of diameters 2, 4 and 6 mm, respectively. A high-speed camera was used to capture bubble dynamics and disclosed the sequence of the process leading to local film boiling. The result shows that local films boiling occurs on the PTFE circle spot at low heat flux and was triggered by the merging of neighboring bubbles. The study also showed that transition time required for change from nucleate boiling regime to local film boiling regime depends on the diameter of the hydrophobic circle spot and the subcooling. A stable local film boiling occurs at the smallest diameter of hydrophobic spot. Subcooling cause the local film boiling occur at negative superheat and oscillation of bubble dome.


Author(s):  
Eu Hwak Lee ◽  
Hee Cheon No ◽  
Dong Won Lee ◽  
Chul Hwa Lee

An experimental study has been performed to investigate thermal-hydraulic phenomena in the downcomer during LBLOCA with Direct Vessel Injection (DVI), which is a new Safety Injection System (SIS) of the Advanced Power Reactor 1400 MW (APR1400). In order to understand the downcomer boiling phenomena experimentally, the KAIST Downcomer Boiling experiment has been performed with the same as the thickness of the reactor vessel of APR1400 (21 cm) and a height of 150 cm to observe downcomer boiling phenomena and to measure local parameters such as local phase velocities, local void fraction, collapsed water level and heat flux from the heated wall. From the KAIST Downcomer Boiling experiment, we visually observed strong liquid recirculation and vapor jetting near the heated wall due to the axial migration of voids only in the thin layer (about 4 cm) of the heated wall but little bubble migration out of the bubble region. Local phase velocities and local void fraction were measured to estimate the drift-flux parameters in the downcomer channel. Heat flux from the heated side was back-calculated to find the CHF and to estimate nucleate boiling heat transfer coefficients.


Sign in / Sign up

Export Citation Format

Share Document