Choosing Working Fluid for Two-Phase Thermosyphon Systems for Cooling of Electronics

2003 ◽  
Vol 125 (2) ◽  
pp. 276-281 ◽  
Author(s):  
Bjo¨rn Palm ◽  
Rahmatollah Khodabandeh

The heat fluxes from electronic components are steadily increasing and have now, in some applications, reached levels where air-cooling is no longer sufficient. One alternative solution, which has received much attention during the last decade, is to use heat pipes or thermosyphons for transferring or spreading the dissipated heat. In this paper two-phase thermosyphon loops are discussed. Especially, the choice of fluid and its influence on the design and performance is treated. The discussion is supported by results from simulations concerning heat transfer and pressure drop. In general it is found that high-pressure fluids will give better performance and more compact designs as high-pressure results in higher boiling heat transfer coefficients and smaller necessary tube diameter.

Author(s):  
Jessica Sheehan ◽  
Avram Bar-Cohen

Heat transfer to an evaporating refrigerant and/or dielectric liquid in a microgap channel can provide very high heat transfer coefficients and volumetric cooling rates. Recent studies at Maryland have established the dominance of the annular flow regime in such microgap channels and related the observed high-quality peak of an M-shaped heat transfer coefficient curve to the onset of local dryout. The present study utilizes infrared thermography to locate such nascent dryout regions and operating conditions. Data obtained with a 210 micron microgap channel, operated with a mass flux of 195.2 kg/m2-s and heat fluxes of 10.3 to 26 W/cm2 are presented and discussed.


Author(s):  
Gilberto Moreno ◽  
Sreekant Narumanchi ◽  
Charles King

This fundamental study characterizes the pool boiling performance of a new refrigerant, HFO-1234yf (hydrofluoroolefin 2,3,3,3-tetrafluoropropene). The similarities in thermophysical properties with HFC-134a and low global warming potential make HFO-1234yf the prospective next generation refrigerant in automotive air-conditioning systems. This study examines the possibility of using this refrigerant for two-phase cooling of hybrid and electric vehicle power electronic components. Pool boiling experiments were conducted with HFO-1234yf and HFC-134a at system pressures ranging from 0.7 to 1.7 MPa using horizontally oriented 1 cm2 heat sources. Results show that the boiling heat transfer coefficients of HFO-1234yf and HFC-134a are nearly identical at lower heat fluxes. HFO-1234yf yielded lower heat transfer coefficients at higher heat fluxes and lower critical heat flux (CHF) as compared with HFC-134a. To enhance boiling heat transfer, a copper microporous coating was applied to the test surfaces. The coating provided enhancement to both the boiling heat transfer coefficients and CHF, for both refrigerants, at all tested pressures. Increasing pressure decreases the level of heat transfer coefficient enhancements while increasing the level of CHF enhancements.


Author(s):  
Alexey Vasilievich Ezhov ◽  
Sergey Sergeevich Ivanov ◽  
Aleksandr Bukin ◽  
Vladimir Grigorievich Bukin

The paper presents the results of an experimental study of the effect of oil on the heat transfer rate at boiling of mixed refrigerant R406A. Since the air conditioning system is not a pure refrigerant, but a mixture of oil with a concentration of up to 8%, such an amount of oil affects both hydrodynamics and heat exchange in the evaporators. The experimental work covers the entire range of regime parameters typical for these systems. There is shown the process of changing oil concentration in the pipe, as the working fluid boils, proving that most of the oil pipe does not impair the heat exchange in the course of two-phase flow boiling. Different modes of refrigerant R406A boiling dynamics have been defined, and each mode is given a quantitative assessment in terms of the effects of the oil and explaining of this effect on the fluid flow and heat transfer based on visual observations and the experiment results. The main factor of the effect is the freon-oil foam, which increases the proportion of the wetted surface in the wave and stratified modes and the heat transfer rate to 30%. A comparison of the heat transfer coefficients both in the cross section and along the pipe length has been performed, showing that the maximum change in heat transfer occurs in the upper part of the surface due to developing a dry wall on it and wetting it with freon-oil foam. A comparison of the heat transfer rate of pure refrigerant R406A has been done; the presence of oil in it shows that the effect of oil is complex and ambiguous. Calculation and criterion dependences for calculation of heat transfer coefficients in different modes have been proposed.


Author(s):  
Kidus Guye ◽  
De Dong ◽  
Yunseo Kim ◽  
Hyoungsoon Lee ◽  
Baris Dogruoz ◽  
...  

Abstract Over the last several decades, cooling technologies have been developed to address the growing thermal challenges associated with high-powered electronics. However, within the next several years, the heat generated by these devices is predicted to exceed 1 kW/cm2, and traditional methods, such as air cooling, are limited in their capacities to dissipate such high heat fluxes. In contrast, two-phase cooling methods, such as microdroplet evaporation, are very promising due to the large latent heat of vaporization associated with the phase change process. Previous studies have shown non-axisymmetric droplets exhibit different evaporation characteristics than spherical droplets. For a droplet pinned atop a micropillar, the solid-liquid and liquid-vapor interfacial area, the volume, and thickness of the droplet are the major factors that govern the evaporation heat transport process. In this work, we develop a shape optimization tool using the particle swarm optimization algorithm to maximize evaporation from a droplet confined atop a micropillar. The tool is used to optimize the shape of a nonaxisymmetric droplet. Compared to droplets atop circular and regular equilateral triangular micropillar structures, we find that droplets confined on pseudo-triangular micropillar structures have 23.7% and 5.7% higher heat transfer coefficients, respectively. The results of this work will advance the design of microstructures that support droplets with maximum heat transfer performance.


Author(s):  
B.S. Larkin

This paper reports tests on a wickless heat pipe to be used for transporting heat from the ground to protect an electronic package from low ambient temperatures. Evaporating heat transfer coefficients were measured for low heat fluxes where the behaviour of the evaporating film is unpredictable. The effects of type of working fluid, heat flux, charge quantity and tube inclination were investigated.


Author(s):  
Jessica Sheehan ◽  
Avram Bar-Cohen

IR thermography of the heated wall for the two-phase flow of FC-72 in microgap channels provides explicit evidence of the quality-driven M-shaped variations in the two-phase microgap heat transfer coefficients. Data obtained from a 210μ microgap channel, operated with an FC-72 mass flux of 195 and 780 kg/m2-s and asymmetric heat fluxes of 28 W/cm2 to 35 W/cm2 are presented and discussed.


2011 ◽  
Vol 133 (5) ◽  
Author(s):  
Saptarshi Basu ◽  
Sidy Ndao ◽  
Gregory J. Michna ◽  
Yoav Peles ◽  
Michael K. Jensen

An experimental study of two-phase heat transfer coefficients was carried out using R134a in uniformly heated horizontal circular microtubes with diameters from 0.50 mm to 1.60 mm over a range of mass fluxes, heat fluxes, saturation pressures, and vapor qualities. Heat transfer coefficients increased with increasing heat flux and saturation pressure but were independent of mass flux. The effects of vapor quality on heat transfer coefficients were less pronounced and varied depending on the quality. The data were compared with seven flow boiling correlations. None of the correlations predicted the experimental data very well, although they generally predicted the correct trends within limits of experimental error. A correlation was developed, which predicted the heat transfer coefficients with a mean average error of 29%. 80% of the data points were within the ±30% error limit.


Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7705
Author(s):  
Anas F. A. Elbarghthi ◽  
Mohammad Yousef Hdaib ◽  
Václav Dvořák

Ejector refrigeration systems are rapidly evolving and are poised to become one of the most preferred cooling systems in the near future. CO2 transcritical refrigeration systems have inherently high working pressures and discharge temperatures, providing a large volumetric heating capacity. In the current research, the heat ejected from the CO2 gas cooler was proposed as a driving heating source for the compression ejector system, representing the energy supply for the generator in a combined cycle. The local design approach was investigated for the combined plate-type heat exchanger (PHE) via Matlab code integrated with the NIST real gas database. HFO refrigerants (1234ze(E) and 1234yf) were selected to serve as the cold fluid on the generator flowing through three different phases: subcooled liquid, a two-phase mixture, and superheated vapour. The study examines the following: the effectiveness, the heat transfer coefficients, and the pressure drop of the PHE working fluids under variable hot stream pressures, cold stream flow fluxes, and superheated temperatures. The integration revealed that the cold fluid mixture phase dominates the heat transfer coefficients and the pressure drop of the heat exchanger. By increasing the hot stream inlet pressure from 9 MPa to 12 MPa, the cold stream two-phase convection coefficient can be enhanced by 50% and 200% for R1234yf and R1234ze(E), respectively. Conversely, the cold stream two-phase convection coefficient dropped by 17% and 37% for R1234yf and R1234ze(E), respectively. The overall result supports utilising the ejected heat from the CO2 transcritical system, especially at high CO2 inlet pressures and low cold channel flow fluxes. Moreover, R1234ze(E) could be a more suitable working fluid because it possesses a lower pressure drop and bond number.


Author(s):  
Emil Rahim ◽  
Avram Bar-Cohen

Forced flow of refrigerants and dielectric liquids, undergoing phase change in a heated microgap channel between chips or in parallel microchannels in a compact cooler, is a promising candidate for the thermal management of advanced semiconductor devices. It has been found that Annular flow is the dominant flow regime in such miniature channels and that relatively high heat transfer coefficients are encountered in the moderate-to-high quality sections of such channels. Following a discussion of flow regimes and thermal characteristics of miniature channels, attention turns to exploring the parametric dependence of annular flow thermal transport in microgaps including the effects of channel diameter, mass flux, and working fluid on the two-phase heat transfer coefficients.


Sign in / Sign up

Export Citation Format

Share Document